Publications by authors named "Petrusca L"

Background: Current treatments of chemotherapy-induced cardiomyopathy (CCM) are of limited efficacy. We assessed whether repeated intravenous injections of human extracellular vesicles from cardiac progenitor cells (EV-CPC) could represent a new therapeutic option and whether EV manufacturing according to a Good Manufacturing Practices (GMP)-compatible process did not impair their bioactivity.

Methods: Immuno-competent mice received intra-peritoneal injections (IP) of doxorubicin (DOX) (4 mg/kg each; cumulative dose: 12 mg/kg) and were then intravenously (IV) injected three times with EV-CPC (total dose: 30 billion).

View Article and Find Full Text PDF

Background And Objective: Ultrafast Power Doppler (UPD) is a growing ultrasound modality for imaging and diagnosing microvasculature disease. A key element of UPD is using singular value decomposition (SVD) as a highly selective filter for tissue and electronic noise. However, two significant drawbacks of SVD are its computational burden and the complexity of its algorithms.

View Article and Find Full Text PDF
Article Synopsis
  • The study aims to enhance myocardial injury assessment through detailed pixel-level analysis using advanced statistical tools, moving beyond traditional global descriptors like size and transmurality.
  • The research analyzed imaging data from 123 STEMI patients in the MIMI trial, comparing outcomes of immediate vs. delayed stenting, while utilizing statistical atlases for pixel-wise comparisons across patient groups.
  • Results indicated that, although global infarct measurements were similar between treatment approaches, delayed stenting showed more pronounced transmurality in specific heart regions, suggesting that detailed analysis can reveal significant local differences in myocardial injury.
View Article and Find Full Text PDF

Introduction: Cardioprotection strategies remain a new frontier in treating acute myocardial infarction (AMI), aiming at further protect the myocardium from the ischemia-reperfusion damage. Therefore, we aimed at investigating the mechano-transduction effects induced by shock waves (SW) therapy at time of the ischemia reperfusion as a non-invasive cardioprotective innovative approach to trigger healing molecular mechanisms.

Methods: We evaluated the SW therapy effects in an open-chest pig ischemia-reperfusion (IR) model, with quantitative cardiac Magnetic Resonance (MR) imaging performed along the experiments at multiple time points (baseline (B), during ischemia (I), at early reperfusion (ER) (∼15 min), and late reperfusion (LR) (3 h)).

View Article and Find Full Text PDF

Quasi-static ultrasound elastography (QSUE) is an imaging technique that mainly provides axial strain maps of tissues when the latter are subjected to compression. In this article, a method for reconstructing the relative shear modulus distribution within a linear elastic and isotropic medium, in QSUE, is introduced. More specifically, the plane stress inverse problem is considered.

View Article and Find Full Text PDF

. Ultrafast power Doppler (UPD) is an ultrasound method that can image blood flow at several thousands of frames per second. In particular, the high number of data provided by UPD enables the use of singular value decomposition (SVD) as a clutter filter for suppressing tissue signal.

View Article and Find Full Text PDF

In the last decade, a large number of clinical trials have been deployed using Cardiac Magnetic Resonance (CMR) to evaluate cardioprotective strategies aiming at reducing the irreversible myocardial damage at the time of reperfusion. In these studies, segmentation and quantification of myocardial infarct lesion are often performed with a commercial software or an in-house closed-source code development thus creating a barrier for reproducible research. This paper introduces CMRSegTools: an open-source application software designed for the segmentation and quantification of myocardial infarct lesion enabling full access to state-of-the-art segmentation methods and parameters, easy integration of new algorithms and standardised results sharing.

View Article and Find Full Text PDF

This study focuses on the reconstruction of the shear modulus contrast in linear elastic and isotropic media, in quasi-static ultrasound elastography. The method proposed is based on the variational formulation of the equilibrium equations and on the choice of adapted discretization spaces to estimate the parameters of interest. Experimental results obtained with CIRS phantoms are presented, for which regions with different mechanical properties can be clearly identified in the stiffness contrast maps.

View Article and Find Full Text PDF

The 2-D sparse arrays, in which a few hundreds of elements are distributed on the probe surface according to an optimization procedure, represent an alternative to full 2-D arrays, including thousands of elements usually organized in a grid. Sparse arrays have already been used in B-mode imaging tests, but their application to Doppler investigations has not been reported yet. Since the sparsity of the elements influences the acoustic field, a corresponding influence on the mean frequency (Fm), bandwidth (BW), and signal-to-noise ratio (SNR) of the Doppler spectra is expected.

View Article and Find Full Text PDF

High frame rate imaging is particularly important in echocardiography for better assessment of the cardiac function. Several studies showed that diverging wave imaging (DWI) and multiline transmission (MLT) are promising methods for achieving a high temporal resolution. The aim of this study was to compare MLT and compounded motion compensation (MoCo) DWI for the same transmitted power, same frame rates [image quality and speckle tracking echocardiography (STE) assessment], and same packet size [tissue Doppler imaging (TDI) assessment].

View Article and Find Full Text PDF

Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach.

View Article and Find Full Text PDF

Purpose: Treatments using high-intensity focused ultrasound (HIFU) in the abdominal region remain challenging as a result of respiratory organ motion. A novel method is described here to achieve 3D motion-compensated ultrasound (US) MR-guided HIFU therapy using simultaneous ultrasound and MRI.

Methods: A truly hybrid US-MR-guided HIFU method was used to plan and control the treatment.

View Article and Find Full Text PDF

Objective: The aim of this paper is to quantitatively investigate the thermal effects generated by the pre-focal interactions of a HIFU beam with a rib cage, in the context of minimally invasive transcostal therapy of liver malignancies.

Materials And Methods: HIFU sonications were produced by a phased-array MR-compatible transducer on Turkey muscle placed on a sheep thoracic cage specimen. The thoracic wall was positioned in the pre-focal zone 3.

View Article and Find Full Text PDF

Magnetic resonance-guided high intensity focused ultrasound (MRgHIFU) is a noninvasive method for thermal ablation, which exploits the capabilities of magnetic resonance imaging (MRI) for excellent visualization of the target and for near real-time thermometry. Oncological quality of ablation may be obtained by volumetric sonication under automatic feedback control of the temperature. For this purpose, a new nonparametric (i.

View Article and Find Full Text PDF

With the availability of new and more accurate tumour treatment modalities such as high-intensity focused ultrasound or proton therapy, accurate target location prediction has become a key issue. Various approaches for diverse application scenarios have been proposed over the last decade. Whereas external surrogate markers such as a breathing belt work to some extent, knowledge about the internal motion of the organs inherently provides more accurate results.

View Article and Find Full Text PDF

Objective: To demonstrate the technical feasibility and the potential interest of using a digital optical camera inside the MR magnet bore for monitoring the breathing cycle and subsequently gating the PRFS MR thermometry, MR-ARFI measurement, and MRgHIFU sonication in the upper abdomen.

Materials And Methods: A digital camera was reengineered to remove its magnetic parts and was further equipped with a 7 m long USB cable. The system was electromagnetically shielded and operated inside the bore of a closed 3T clinical scanner.

View Article and Find Full Text PDF

Background: Magnetic Resonance-guided High Intensity Focused Ultrasound (MRgHIFU) is a hybrid technology that aims to offer non-invasive thermal ablation of targeted tumors or other pathological tissues. Acoustic aberrations and non-linear wave propagating effects may shift the focal point significantly away from the prescribed (or, theoretical) position. It is therefore mandatory to evaluate the spatial accuracy of ablation for a given HIFU protocol and/or device.

View Article and Find Full Text PDF

Purpose: Magnetic resonance-guided high-intensity focused ultrasound is considered to be a promising treatment for localized cancer in abdominal organs such as liver, pancreas, or kidney. Abdominal motion, anatomical arrangement, and required sustained sonication are the main challenges.

Methods: MR acquisition consisted of thermometry performed with segmented gradient-recalled echo echo-planar imaging, and a segment-based one-dimensional MR navigator parallel to the main axis of motion to track the organ motion.

View Article and Find Full Text PDF

Extracorporeal high-intensity focused ultrasound (HIFU) is a minimally invasive therapy considered with increased interest for the ablation of small tumors in deeply located organs while sparing surrounding critical tissues. A multitude of preclinical and clinical studies have showed the feasibility of the method; however, concurrently they showed several obstacles, among which the management of respiratory motion of abdominal organs is at the forefront. The aim of this review is to describe the different methods that have been proposed for managing respiratory motion and to identify their advantages and weaknesses.

View Article and Find Full Text PDF

Magnetic resonance-guided high-intensity focused ultrasound (MRgHIFU, or MRgFUS) is a hybrid technology that was developed to provide efficient and tolerable thermal ablation of targeted tumors or other pathologic tissues, while preserving the normal surrounding structures. Fast 3-D ablation strategies are feasible with the newly available phased-array HIFU transducers. However, unlike fixed heating sources for interstitial ablation (radiofrequency electrode, microwave applicator, infra-red laser applicator), HIFU uses propagating waves.

View Article and Find Full Text PDF

Objectives: The combination of ultrasound (US) and magnetic resonance imaging (MRI) may provide a complementary description of the investigated anatomy, together with improved guidance and assessment of image-guided therapies. The aim of the present study was to integrate a clinical setup for simultaneous US and magnetic resonance (MR) acquisition to obtain synchronized monitoring of liver motion. The feasibility of this hybrid imaging and the precision of image fusion were evaluated.

View Article and Find Full Text PDF

Objectives: The treatment of liver cancer is a major public health issue because the liver is a frequent site for both primary and secondary tumors. Rib heating represents a major obstacle for the application of extracorporeal focused ultrasound to liver ablation. Magnetic resonance (MR)-guided external shielding of acoustic obstacles (eg, the ribs) was investigated here to avoid unwanted prefocal energy deposition in the pathway of the focused ultrasound beam.

View Article and Find Full Text PDF

High intensity focused ultrasound (HIFU) under MRI guidance may provide minimally invasive treatment for localized prostate cancer. In this study, ex vivo and in vivo experiments were performed using a prostate-dedicated endorectal phased array (16 circular elements arranged on a truncated spherical cap of radius 60 mm) and a translation-rotation mechanical actuator in order to evaluate the lesion formation and the potential interest of dual-modality (electronic and mechanical) interleaved displacement of the focus for volumetric sonication paradigms. Different sonication sequences, including elementary lesions, line scan, slice sweeping and volume sonications, were investigated with a clinical 1.

View Article and Find Full Text PDF

Magnetic resonance imaging (MRI) and ultrasonography have been used simultaneously in this ex vivo study for the image-guidance of high intensity focused ultrasound (HIFU) treatment in moving tissue. A ventilator-driven balloon produced periodic and non-rigid (i.e.

View Article and Find Full Text PDF