Publications by authors named "Petr Solich"

The extraction efficiencies of thirty types of fibers produced by meltblown, alternating current electrospinning, and meltblown-co-electrospinning technologies were tested as advanced sorbents for on-line solid-phase extraction in a high-performance liquid chromatography system have been tested and compared with a commercial C18 sorbent. The properties of each fiber, which were often depended on the production process, and their applicability were demonstrated with the extraction of the model analytes nitrophenols and chlorophenols from various matrices including river water and to purify complex matrix human serum and bovine serum albumin from macromolecular ballast. Polycaprolactone fibers outperformed other polymers and were selected for subsequent modifications including (i) incorporation of hybrid carbon nanoparticles, i.

View Article and Find Full Text PDF

A sample preparation method involving tandem implementation of protein precipitation and salting-out homogenous liquid-liquid extraction was developed for the determination of beta-blockers in serum. The entire procedure was automated using a computer-controlled syringe pump following the Lab-In-Syringe approach. It is based on the denaturation of serum proteins with acetonitrile followed by salt-induced phase separation upon which the proteins accumulate as a compact layer at the interphase of the solutions.

View Article and Find Full Text PDF

In this work, we describe for the first time the use of iron(III) thenoyltrifluoroacetonate complex (Fe(TTA)) as a novel sorbent for solvent-assisted dispersive micro-solid phase extraction (SA-dμSPE) of bisphenols from water samples. The extraction procedure is based on the formation of nanoparticles following the rapid injection of a methanolic solution of Fe(TTA) into the stirred aqueous sample. Herein, the synthesis of Fe(TTA) and study of the essential parameters of the preparative procedure are described.

View Article and Find Full Text PDF

Reaction-based assays are commonly automated and miniaturized via flow analysis. However, aggressive reagents can affect or destroy even the chemically resistant manifold during long-term use. Using on-line solid-phase extraction (SPE) can eliminate this drawback and allow for high reproducibility and further advanced automation, as presented in this work.

View Article and Find Full Text PDF

A novel approach to the determination of sulfonamides in milk based on the Lab-In-Syringe technique is presented. The method involves automated salting-out liquid-liquid extraction of the analytes, allowing simultaneous sample deproteination without requiring centrifugation or manual sample handling. The procedural parameters, including salt type, solvent-to-sample ratio, and salt solution volume, were studied.

View Article and Find Full Text PDF

Advanced solid phase extraction (SPE) fibrous sorbents including polyethylene, polypropylene poly (hydroxybutyrate), and polyamide 6 nanofibers, polycaprolactone microfibers/nanofibers, polycaprolactone microfibers/polyvinylidene difluoride nanofibers, and poly (hydroxybutyrate) microfibers/polypropylene microfibers composites, as well as commercial molecularly imprinted polymers and restricted access media sorbent were compared in terms of bisphenols extraction from milk and their clean-up efficiency. Three on-line SPE-HPLC methods were completely validated for the extraction and detection of bisphenols A, AF, C, A diglycidyl ether, and F diglycidyl ether in bovine milk. Polycaprolactone composite nanofibers compared favorably to restricted access media, enabled excellent clean-up of bisphenols from the proteinaceous matrix, and yielded recoveries 98.

View Article and Find Full Text PDF

Unlabelled: Para Red (PR) and Sudan dyes have been illegally used as colorants to adulterate certain foods by enhancing their red/orange colour. In addition, they are toxic and carcinogenic. This work presents the development of a simple flow injection chromatographic method combined with chemometric tools to perform the determination of PR, Sudan I (SI) and Sudan II (SII) in food samples.

View Article and Find Full Text PDF

An automated methodology for magnetic dispersive solid phase microextraction integrating bead injection approach for renewable sorbent introduction is presented for the first time and was successfully applied to the enrichment of water contaminants. For this purpose, a simple procedure was developed for the functionalization of commercial SupelTM-Select HLB (Hydrophilic modified styrene polymer) sorbent beads that allowed embedding magnetite nanoparticles (FeO). The sorbent was then used in a dispersive solid phase extraction procedure that was carried out entirely inside the void of an automatic syringe pump following the flow-batch concept of Lab-In-Syringe including automated renewal of the sorbent for each analysis.

View Article and Find Full Text PDF

Lab-In-Syringe direct immersion single drop microextraction is proposed as an automated sample pretreatment methodology and coupled online to HPLC with fluorescence detection for the determination of fluoroquinolones in environmental waters. For the first time, a drop of a natural deep eutectic solvent (NADES), synthesized from hexanoic acid and thymol, has been used as an extractant in automated single-drop microextraction. The extraction procedure was carried out within the 5 mL void of an automatic syringe pump.

View Article and Find Full Text PDF

A fully automated sequential injection system was tested in terms of its application in liberation testing, and capabilities and limitations were discussed for clotrimazole liberation from three semisolid formulations. An evaluation based on kinetic profiles obtained in short and longer sampling intervals and steady-state flux values were applied as traditional methods. The obtained clotrimazole liberation profile was faster in the case of Delcore and slower for Clotrimazol AL and Canesten cream commercial formulations.

View Article and Find Full Text PDF

We report on the hyphenation of the modern flow techniques Lab-In-Syringe and Lab-On-Valve for automated sample preparation coupled online with high-performance liquid chromatography. Adopting the bead injection concept on the Lab-On-Valve platform, the on-demand, renewable, solid-phase extraction of five nonsteroidal anti-inflammatory drugs, namely ketoprofen, naproxen, flurbiprofen, diclofenac, and ibuprofen, was carried out as a proof-of-concept. In-syringe mixing of the sample with buffer and standards allowed straightforward pre-load sample modification for the preconcentration of large sample volumes.

View Article and Find Full Text PDF

Bcr-Abl tyrosine kinase inhibitors significantly improved Philadelphia chromosome-positive leukaemia therapy. Apart from Bcr-Abl kinase, imatinib, dasatinib, nilotinib, bosutinib and ponatinib are known to have additional off-target effects that might contribute to their antitumoural activities. In our study, we identified aldo-keto reductase 1B10 (AKR1B10) as a novel target for dasatinib.

View Article and Find Full Text PDF

Effect of physicochemical properties including dissociation constant (pKa) and partition coefficient (log P) of the compounds on their extraction efficiency in sample preparation using fibrous polymer sorbents has been demonstrated. Poly-ε-caprolactone as meltblown/electrospun composite fibers, and polypropylene, polyethylene, poly(3-hydroxybutyrate), poly(lactic acid), and polyamide 6 in the meltblown fiber format were used as sorbents in solid-phase extraction. In addition, the polycaprolactone fibers were coated with dopamine, dopamine combined with heparin, and tannin, respectively, to modify their extraction properties.

View Article and Find Full Text PDF

A new design of permeation module based on 3D printing was developed to monitor the interaction of exogenic compounds with cell membrane transporters in real-time. The fluorescent marker Rhodamine 123 (Rho123) was applied as a substrate to study the activity of the P-glycoprotein membrane transporter using the MDCKII-MDR1 genetically modified cell line. In addition, the inhibitory effect of verapamil (Ver), a prototype P-glycoprotein inhibitor, was examined in the module, demonstrating an enhanced Rho123 transfer and accumulation into cells as well as the applicability of the module for P-glycoprotein inhibitor testing.

View Article and Find Full Text PDF

According to the EU legislation, ochratoxin A contamination is controlled in wines. Tokaj wine is a special type of sweet wine produced from botrytized grapes infected by "noble rot" . Although a high contamination was reported in sweet wines and noble rot grapes could be susceptible to coinfection with other fungi, including ochratoxigenic species, no screening of Tokaj wines for mycotoxin contamination has been carried out so far.

View Article and Find Full Text PDF

A double-stage Lab-In-Syringe automated extraction procedure coupled online to HPLC for the determination of four sulfonamides in urine has been developed. Our method is based on homogeneous liquid-liquid extraction at pH 3 using water-miscible acetonitrile with induction of phase separation by the addition of a saturated solution of kosmotropic salts MgSO and NaCl. The procedure allowed extraction of the moderately polar model analytes and the use of a solvent that is compatible with the used separation technique.

View Article and Find Full Text PDF

Effective process, including a cartridge packing polypropylene fiber sorbent modified by following on-line polydopamine coating, for on-line solid phase extraction in 2D UHPLC system has been developed. Hydrophobic surface of mechanically stable polypropylene fibers was hydrophilized using an automated and reproducible in situ coating process to enable good wettability and effective extraction of polar compounds. Polymerization mixture consisting dopamine and TRIS buffer was circulated through the cartridge containing polypropylene fibers using a peristaltic pump to achieve polymerization.

View Article and Find Full Text PDF

The reduction of free radicals by bioactive membranes used for hemodialysis treatment is an important topic due to the constant rise of oxidative stress-associated cardiovascular mortality by hemodialysis patients. Therefore, it is urgent to find an effective solution that helps to solve this problem. Polysulfone membranes enriched with α-lipoic acid, α-tocopherol, and with both components are fabricated by spin coating.

View Article and Find Full Text PDF

Polymers in nanofiber format promise a great potential as sorbents for extraction techniques. This tutorial provides an overview of direct coupling of extraction techniques based on nanofibers to liquid chromatography. Arrangements of the fibers in conventional extraction cartridges are demonstrated.

View Article and Find Full Text PDF

Poly-ε-caprolactone nanofibrous polymer has been used as an alternative to restricted access media for extraction of protein-containing biological samples and direct transfer in the chromatographic system. Three commercial cartridges differing in length and internal diameter have been manually packed with the composite material prepared from poly-ε-caprolactone nanofibers coated on poly-ε-caprolactone microfibrous scaffold and connected to the column-switching chromatographic system. Bovine milk and human serum (25 μL) spiked with a mixture of methyl-, ethyl-, propyl-, and butylparaben in a concentration range of 1-100 μg mL were online extracted using the cartridge-containing fibers.

View Article and Find Full Text PDF

About eight years ago, a new automation approach and flow technique called "Lab-In-Syringe" was proposed. It was derived from previous flow techniques, all based on handling reagent and sample solutions in a flow manifold. To date Lab-In-Syringe has evidently gained the interest of researchers in many countries, with new modifications, operation modes, and technical improvements still popping up.

View Article and Find Full Text PDF

A magnetic stirring device allowing semidispersive solid phase extraction of eight bisphenols (A, AF, AP, C, BP, G, M, and Z) from river waters using polymer nano- and microfibers followed by HPLC with spectrophotometric detection has been developed and applied. About 50 mg of fibers was placed in a round, cage-like housing consisting of two identical 3D printed pieces that were locked together by a magnetic stirring bar. Magnetic stirring action of the cage devices enabled highly efficient interaction of the fibers housed inside with the aqueous samples and analyte transfer without risking fiber compaction and/or damaging.

View Article and Find Full Text PDF

Polycaprolactone composite nanofibers coated with a polydopamine layer are introduced as a new type of absorption material for on-line solid phase extraction (SPE) in chromatographic system. A hybrid technology combining the electrospinning and melt blowing was used for the preparation of 3D-structured microfiber/nanofibrous polycaprolactone composite. The dopamine coating was then applied to functionalize the micro/nanofibers.

View Article and Find Full Text PDF

On-line SPE HPLC method using nanofibrous sorbents for the extraction and determination of resveratrol in wine was developed and validated. Different types of nanofibrous and microfibrous polymers were tested and compared with commercial monolithic C18 sorbent. Polyamide and polyacrylonitrile nanofibers and composite materials composed of respective polycaprolactone and poly(vinylidene difluoride) nanofibers at microfibrous scaffold were included among tested materials.

View Article and Find Full Text PDF