This study investigated methods for sampling bile acids in saliva, a potential non-invasive diagnostic biofluid. Bile acids have been implicated in causing damage and permanent changes to the esophageal mucosa and increasing the risk of developing Barrett's esophagus, a condition that can potentially progress to esophageal cancer. Three saliva collection methods were compared: spitting, Salivette® swabs, and Salivette Cortisol® swabs.
View Article and Find Full Text PDFBiological thiols spontaneously form a stable Au-S dative bond with gold nanoparticles (AuNP) that might be used for their selective extraction and enrichment in biological samples. In this work, interactions of selected biological thiols (glutathione, cysteine, homocysteine [Hcys], cysteamine [CA], and N-acetylcysteine) with AuNP stabilized by different capping agents (citrate, Tween 20, Brij 35, CTAB, SDS) were investigated by UV-Vis spectroscopy and capillary electrophoresis with laser-induced fluorescence. Spectrophotometric measurements showed aggregation of Hcys and CA with AuNP.
View Article and Find Full Text PDFBackground: In-house built capillary electrophoresis (CE) systems represent a significant share of laboratory instrumentation. In most of these instruments, sample injection is effected manually with low to moderate precision and requires skilled operators. Although few automated samplers have been previously developed, typically only one sample at a time can be injected.
View Article and Find Full Text PDFMetal nanoparticles (NPs) exhibit several unique physicochemical properties, including redox activity, surface plasmon resonance, ability to quench fluorescence, biocompatibility, or a high surface-to-volume ratio. They are being increasingly used in analysis and preconcentration of thiol containing compounds, because they are able to spontaneously form a stable Au/Ag/Cu-S dative bond. They thus find wide application in environmental and particularly in medical science, especially in the analysis of biological thiols, the endogenous compounds that play a significant role in many biological systems.
View Article and Find Full Text PDFBile acids are a group of steroid compounds essential for lipid digestion. However, when bile acids are refluxed into the stomach and the esophagus, during the so called duodenogastroesophageal reflux, they can have a detrimental effect on the esophageal epithelium and cause pathological changes of esophageal tissue, e.g.
View Article and Find Full Text PDFExhaled breath condensate (EBC) is an attractive, non-invasive sample for clinical diagnostics. During EBC collection, its composition is influenced by the collection temperature, a factor that is often not thoroughly monitored and controlled. In this study, we assembled a novel, simple, portable, and inexpensive device for EBC collection, able to maintain a stable temperature at any value between -7 °C and +12 °C.
View Article and Find Full Text PDFA simple and fast method for the analysis of lactate from a single drop of blood was developed. The finger-prick whole blood sample (10 µL) was diluted (1:20) with a 7% (/) solution of [tris(hydroxymethyl)methylamino] propanesulfonic acid and applied to a blood plasma separation device. The device accommodates a membrane sandwich composed of an asymmetric polysulfone membrane and a supporting textile membrane that allows the collection of blood plasma into a narrow glass capillary in less than 20 s.
View Article and Find Full Text PDFA fast method for the determination of tropane alkaloids, using a portable CE instrument with a capacitively coupled contactless conductivity detector (CE-CD) was developed and validated for determination of atropine and scopolamine in seeds from family plants. Separation was obtained within 5 min, using an optimized background electrolyte consisting of 0.5 M acetic acid with 0.
View Article and Find Full Text PDFIn this work, we have designed, constructed, and evaluated simple, inexpensive open-source data acquisition systems based on various analog-to-digital converter modules (ADS 1115, MCP 3424, LTC 2400, with resolution from 16 to 24-bit) and a miniature Arduino Nano ™ microcontroller. The constructed data acquisition systems provide excellent performance and are comparable to a commercial, 24-bit device. We provide full schematics and corresponding source codes so that analytical chemists can easily construct any of the developed systems without extensive electronic or programming knowledge.
View Article and Find Full Text PDFA fast, non-invasive, high-performance liquid chromatographic screening method with electrospray ionization mass spectrometric detection was developed for the analysis of three major glycine-conjugated bile acids in human saliva. Using a mobile phase composed of 80% methanol and 0.1% formic acid, glycocholic, glycodeoxycholic, and glycochenodeoxycholic acids were separated in less than 4 minutes with sensitivity in the low nM range.
View Article and Find Full Text PDFBile acids are a group of compounds essential for lipid digestion and absorption with a steroid skeleton and a carboxylate side chain usually conjugated to glycine or taurine. Bile acids are regulatory molecules for a number of metabolic processes and can be used as biomarkers of various disorders. Since the middle of the twentieth century, the detection of bile acids has evolved from simple qualitative analysis to accurate quantification in complicated mixtures.
View Article and Find Full Text PDFObjective: To assess the performance of a newly developed skin wipe test (SWT) for the diagnosis of cystic fibrosis (CF).
Study Design: Spontaneously formed sweat from the forearm was wiped by a cotton swab moistened with 100 µL of deionized (DI) water and extracted into 400 µL of DI water (SWT). The conventional Macroduct sweat test (ST) was performed simultaneously.
J Chromatogr B Analyt Technol Biomed Life Sci
December 2019
In this study, the ionic profile and pH of exhaled breath condensate (EBC) in a group of patients with acid and weakly acid reflux and no-reflux controls were compared. A portable sampler was used for non-invasive EBC collection from five exhalations. The ionic profile (anions, cations, organic acids) and pH of the collected EBC samples were measured by capillary electrophoresis with contactless conductivity detection and a pH microelectrode, respectively.
View Article and Find Full Text PDFBicarbonate and phosphate constitute major salivary buffering components, and their importance consists in the neutralization of acidic gastric contents during reflux episodes. In this work, capillary electrophoresis with capacitively coupled contactless conductivity detector was applied for the analysis of bicarbonate, phosphate, and another inorganic (chloride, nitrite, nitrate, sulfate, thiocyanate) and organic anions (acetate, butyrate) to evaluate their levels in saliva. The background electrolytes of different composition and pH between 6.
View Article and Find Full Text PDFIn this article, optimization of BGE for simultaneous separation of inorganic ions, organic acids, and glutathione using dual C D-LIF detection in capillary electrophoresis is presented. The optimized BGE consisted of 30 mM 2-[4-(2-hydroxyethyl)piperazin-1-yl]ethanesulfonic acid, 15 mM 2-amino-2-hydroxymethyl-propane-1,3-diol, and 2 mM 18-crown-6 at pH 7.2 and allowed simultaneous separation of ten inorganic anions and cations, three organic acids and glutathione in 20 min.
View Article and Find Full Text PDFIn recent years, advances in sensitive analytical techniques have encouraged the analysis of various compounds in biological fluids. While blood serum, blood plasma and urine still remain the golden standards in clinical, toxicological and forensic science, analyses of other body fluids, such as breast milk, exhaled breath condensate, sweat, saliva, amniotic fluid, cerebrospinal fluid, or capillary blood in form of dried blood spots are becoming more popular. This review article focuses on capillary electrophoresis and microchip electrophoresis of small ions and molecules (e.
View Article and Find Full Text PDFOpen source paradigm is becoming widely accepted in scientific communities and open source hardware is finding its steady place in chemistry research. In this review article, we provide the reader with the most up-to-date information on open source hardware and software resources enabling the construction and utilization of an "open source capillary electrophoresis instrument". While CE is still underused as a separation technique, it offers unique flexibility, low-cost, and high efficiency and is particularly suitable for open source instrumental development.
View Article and Find Full Text PDFGoal: To evaluate the analytical parameters of a lateral flow (LF) pepsin immunoassay (Peptest) and assess its suitability in the diagnostics of gastroesophageal reflux disease (GERD).
Background: Peptest is a noninvasive assay to analyze pepsin in saliva, intended for use in GERD diagnostics. Although commercialized, fundamental studies on its performance are missing.
In this work, a simple device for extremely fast separation of blood plasma from diluted whole blood was developed. The device accommodates an asymmetric polysulfone membrane/supporting membrane sandwich that allows collection of 10 µL blood plasma into a narrow glass capillary in less than 10 s. The composition of diluent solution was optimized in order to achieve maximum recoveries for selected metabolites of alcohol intoxication.
View Article and Find Full Text PDFCapillary electrophoresis (CE) can provide high separation efficiency with very simple instrumentation, but has yet to be explored regarding oxysterols/cholesterol. Cholesterol and 25-hydroxycholesterol (both are 4-ene-3-ketosteroids) were quantitatively transformed into hydrazones using Girard P reagent after enzymatic oxidation by cholesterol oxidase. Separation was achieved using non-aqueous capillary electrophoresis with UV detection at 280nm; the "charge-tagging" Girard P reagent ensured both charge and chromophore (which are requirements for CE-UV).
View Article and Find Full Text PDFIn this work, a sensitive capillary electrophoresis method with laser induced fluorescence detection for determination of malondialdehyde in various biological fluids was developed. Malondialdehyde reacts with thiobarbituric acid under optimized conditions of pH=2, reaction time of 60min and temperature of 90°C, yielding an adduct that can be separated in a 50mM sodium borate background electrolyte at pH 9. The separation of the formed adduct was accomplished in less than 6min with limit of detection of 1.
View Article and Find Full Text PDFA new approach for sweat analysis used in cystic fibrosis (CF) diagnosis is proposed. It consists of a noninvasive skin-wipe sampling followed by analysis of target ions using capillary electrophoresis with contactless conductometric detection (C4D). The skin-wipe sampling consists of wiping a defined skin area with precleaned cotton swab moistened with 100 μL deionized water.
View Article and Find Full Text PDFElectrophoresis
January 2017
In this review article, CE methods for analysis of biologically important thiols are overviewed. The article covers the period from the previously published comprehensive review in 2004 until mid-2016, with emphasis on various detection modes, novel approaches for sample preconcentration, and applications in clinical practice. The most commonly used detection methods, such as conductometry or absorbance detection, although universally applicable and available in most commercial instruments have low sensitivity and have only limited use in thiol analysis.
View Article and Find Full Text PDFIn this work aqueous infusions from ten Mentha herbal samples (four different Mentha species and six hybrids of Mentha x piperita) and 20 different peppermint teas were screened by capillary electrophoresis with UV detection. The fingerprint separation was accomplished in a 25 mM borate background electrolyte with 10% methanol at pH 9.3.
View Article and Find Full Text PDFOrganic acids, deacetyl asperulosidic acid (DAA) and polyphenolic compounds in various noni (Morinda citrifolia L.) products (4 juices, 4 dry fruit powders and 2 capsules with dry fruit powder) were analyzed. Reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a variable wavelength detector (VWD) and electrospray ionization time-of-flight mass spectrometer (ESI-TOF MS) was applied for simultaneous analysis of organic acids (malic, lactic, citric and succinic acid) and DAA.
View Article and Find Full Text PDF