Phys Imaging Radiat Oncol
January 2024
Background And Purpose: Individual elective lymph node irradiation instead of elective neck irradiation is a new concept for head-and-neck cancer (HNC) patients developed for the Magnetic Resonance Image guided linear accelerator (MR-linac). To prepare this, the detectability, volume changes and intra-fraction motion of elective lymph nodes on the MR-linac was assessed.
Materials And Methods: A total of 15 HNC patients underwent diagnostic pre-treatment MRI.
Background And Purpose: To decrease the impact of radiotherapy to healthy tissues in the head and neck region, we propose to restrict the elective neck irradiation to elective lymph nodes at risk of containing micro metastases instead of the larger lymph node volumes. To assess whether this new concept is achievable in the clinic, we determined the number, volume changes and displacement of elective lymph nodes during the course of radiotherapy.
Materials And Methods: MRI scans of 10 head and neck cancer (HNC) patients were acquired before radiotherapy and in week 2, 3, 4 and 5 during radiotherapy.
Patients with medical implants often are deprived of magnetic resonance imaging examination because of safety risks. One specific risk is the enhancement of the radiofrequency fields around the medical implant potentially resulting in significant tissue heating and damage. The assessment of this enhancement is a computationally demanding task, with simulations taking hours or days to converge.
View Article and Find Full Text PDFPurpose: To propose a single setup using the MRI to both measure and validate the transfer function (TF) of linear implants. Conventionally, the TF of an implant is measured in one bench setup and validated using another.
Methods: It has been shown that the TF can be measured using MRI.
Purpose: To remove the necessity of the tranceive phase assumption for CSI-EPT and show electrical properties maps reconstructed from measured data obtained using a standard 3T birdcage body coil setup.
Methods: The existing CSI-EPT algorithm is reformulated to use the transceive phase rather than relying on the transceive phase assumption. Furthermore, the radio frequency (RF)-shield is numerically implemented to accurately model the RF fields inside the MRI scanner.
Purpose: Patients who have medical metallic implants, e.g. orthopaedic implants and pacemakers, often cannot undergo an MRI exam.
View Article and Find Full Text PDF