Publications by authors named "Peter P De Jaegere"

Background: Calcium is a determinant of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI). This is based on a fixed contrast attenuation value while X-ray attenuation is patient-dependent and without considering frame expansion and PVL location. We examined the role of calcium in (site-specific) PVL after TAVI using a patient-specific contrast attenuation coefficient combined with frame expansion.

View Article and Find Full Text PDF

Background: Multislice computed tomography (MSCT) may reveal hypo-attenuated leaflet thickening (HALT) and/or reduced leaflet motion (RELM) in approximately 15 % of patients after transcatheter aortic valve replacement (TAVR). These supposedly thrombogenic phenomena may be associated with neurological events and increased transprosthetic gradients. It is unclear whether oral anticoagulant therapy -specifically a factor Xa inhibitor- could affect the incidence of HALT/RELM.

View Article and Find Full Text PDF

Background: The mechanically-expandable transcatheter valve is no longer commercially available, yet clinical and echocardiographic surveillance is imperative for thousands of patients who received transcatheter aortic valve implantation (TAVI) with this platform.

Aims: We aimed to determine the incidence and mechanism of bioprosthetic valve dysfunction (BVD) following TAVI with mechanically-expandable valves.

Methods: From 2013 to 2020, all 234 patients who underwent TAVI with the LOTUS valve were included.

View Article and Find Full Text PDF

Objectives: To study the safety and feasibility of a restrictive temporary-RV-pacemaker use and to evaluate the need for temporary pacemaker insertion for failed left ventricular (LV) pacing ability (no ventricular capture) or occurrence of high-degree AV-blocks mandating continuous pacing.

Background: Ventricular pacing remains an essential part of contemporary transcatheter aortic valve implantation (TAVI). A temporary-right-ventricle (RV)-pacemaker lead is the standard approach for transient pacing during TAVI but requires central venous access.

View Article and Find Full Text PDF

Background: Functional mitral regurgitation (FMR) can be subclassified on the basis of its proportionality relative to left ventricular (LV) volume and function, indicating potential differences in underlying etiology. The aim of this study was to evaluate the association of FMR proportionality with FMR reduction, heart failure hospitalization and mortality after transcatheter edge-to-edge mitral valve repair (TEER).

Methods: This multicenter registry included 241 patients with symptomatic heart failure with reduced LV ejection fraction treated with TEER for moderate to severe or greater FMR.

View Article and Find Full Text PDF

Aims: To elucidate the frequency and clinical impact of left atrial appendage thrombus (LAAT) in patients set for transcatheter aortic valve implantation (TAVI).

Methods And Results: All patients undergoing TAVI between January 2014 and June 2020 with analysable multislice computed tomography (MSCT) for LAAT were included. Baseline and procedural characteristics were collected, pre-procedural MSCT's were retrospectively analysed for LAAT presence.

View Article and Find Full Text PDF

A plethora of catheter-based strategies have been developed to treat mitral valve disease. Evolving 3-dimensional (3D) multidetector computed tomography (MDCT) technology can accurately reconstruct the mitral valve by means of 3-dimensional computational modeling (3DCM) to allow virtual implantation of catheter-based devices. 3D printing complements computational modeling and offers implanting physician teams the opportunity to evaluate devices in life-size replicas of patient-specific cardiac anatomy.

View Article and Find Full Text PDF

Background The need for new permanent pacemaker implantation (PPI) after Transcatheter Aortic Valve Implantation (TAVI) remains a critical issue. Membranous Septum (MS) length is associated with PPI after TAVI. The aim of this study was to identify different MS thresholds for the contemporary THV-platforms.

View Article and Find Full Text PDF

With innovations in therapeutic technologies and changes in population demographics, transcatheter interventions for structural heart disease have become the preferred treatment and will keep growing. Yet, a thorough clinical selection and efficient pathway from diagnosis to treatment and follow-up are mandatory. In this review we reflect on how artificial intelligence may help to improve patient selection, pre-procedural planning, procedure execution and follow-up so to establish efficient and high quality health care in an increasing number of patients.

View Article and Find Full Text PDF

Introduction: We aimed to compare conduction dynamics and need for permanent pacemaker implantation (PPI) after CoreValve, Evolut R and PRO (transcatheter aortic valve replacement (TAVR)).

Methods: Patients were stratified based on conduction at baseline; Cohort A had normal conduction, Cohort B had conduction abnormalities including atrioventricular (AV)-block, fascicular block or complete bundle branch block. Three different dynamic QRS-patterns were defined: stable QRS-duration, transient QRS-prolongation and persistent QRS-prolongation.

View Article and Find Full Text PDF

Background: The MANTA vascular closure device (VCD) is dedicated to large bore access closure and associated with favorable results in selected study populations. Anatomical predictors for access site complications are lacking.

Aim: To evaluate MANTA in a real-world population and identify predictors for vascular complications.

View Article and Find Full Text PDF

Little data are available on access strategy outcomes for cardiac catheterizations in patients with prior coronary artery bypass graft surgery (CABG). We investigated the effect of transradial access (TRA) and transfemoral access (TFA) on short-term major vascular complications (MVC) and long-term major adverse cardiovascular events (MACE). In this single-center, retrospective cohort study, 1084 patients met our inclusion criteria (TRA = 469; TFA = 615).

View Article and Find Full Text PDF

Objectives: This study sought to test the superiority in terms of efficacy and safety of a dedicated plug-based vascular closure device (VCD) during transcatheter aortic valve replacement (TAVR) over a suture-based VCD.

Background: Vascular complications after TAVR are relevant and often associated with VCD failure.

Methods: The MASH (MANTA vs.

View Article and Find Full Text PDF

Objectives: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers.

Background: The MANTA is a novel plug-based device for large bore arteriotomy closure.

Methods: We included all eligible patients who underwent transfemoral large bore percutaneous procedures.

View Article and Find Full Text PDF

Background: The axillary artery is an alternative route for patients with comorbidities and unfavorable femoral arteries who need transcatheter aortic valve replacement (TAVR). Simplified trans-axillary transcatheter aortic valve replacement (TAx-TAVR) implies a completely percutaneous approach under local anesthesia and arteriotomy closure with vascular closure techniques. Herein, we report on early experience with simplified TAx-TAVR under local anesthesia.

View Article and Find Full Text PDF

Background: The optimal antithrombotic therapy after transcatheter aortic valve implantation (TAVI) is unsettled. Short and longer-term thromboembolic and bleeding risk post TAVI remain high. Non-vitamin K oral anticoagulant drugs (NOAC) may be attractive after TAVI but the implications of prolonged NOAC in this setting require further research.

View Article and Find Full Text PDF

Precision medicine has recently become widely advocated. It revolves around the individual patient, taking into account genetic, biomarker, phenotypic or psychosocial characteristics and uses biological, mechanical and/or personal variables to optimise individual therapy. testing, such as the Virtual Physiological Human project, is being promoted to predict risk and to test treatments and medical devices.

View Article and Find Full Text PDF

Background: Both aortic valve stenosis and aortic stiffness are moderators of arterio ventricular coupling and independent predictors of cardiovascular morbidity and mortality. Studies on the effect of transcatheter aortic valve implantation (TAVI) on aortic functional properties are limited. We performed a study to investigate the possible short-term changes in aortic stiffness and other aortic functional properties after TAVI in older patients.

View Article and Find Full Text PDF

Objectives: To assess the performance of the commercially available Magmaris sirolimus-eluting bioresorbable scaffold (BRS) with invasive imaging at different time points.

Background: Coronary BRS with a magnesium backbone have been recently studied as an alternative to polymeric scaffolds, providing enhanced vessel support and a faster resorption rate. We aimed to assess the performance of the commercially available Magmaris sirolimus-eluting BRS at different time points.

View Article and Find Full Text PDF

Moderate aortic stenosis (AS) and reduced left ventricular ejection fraction (LVEF) constitute a clinical entity that has been proposed as a therapeutic target for transcatheter aortic valve replacement (TAVR). It is defined by a mean trans-aortic gradient between 20 and 40 mmHg and an aortic valve area between 1.0 and 1.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve implantation (TAVI) has become the standard treatment for patients with severe symptomatic aortic stenosis (AS) considered at very high risk for surgical aortic valve replacement. The purpose of this sub-study was to evaluate long-term (> 4 years) health-related quality of life (QoL) in octogenarians who underwent TAVI.

Methods: A single center observational registry in twenty patients who underwent frame analysis assessment ≥ 4 years after TAVI.

View Article and Find Full Text PDF

Aims: To correlate dynamics in electrical conduction after transcatheter aortic valve implantation (TAVI) with need for permanent pacemaker implantation (PPM) and assess implications for early discharge.

Methods And Results: Daily electrocardiograms after TAVI were analysed for rhythm and conduction times and were correlated with PPM. Transcatheter aortic valve implantation was performed in 291 consecutive patients with three contemporary transcatheter heart valve designs: Medtronic CoreValve (n = 111), Edwards Sapien XT (n = 29) and Sapien 3 (n = 72), and Boston Lotus (n = 79).

View Article and Find Full Text PDF

Background And Aims: Significant left main (LM) stem disease is potentially life-threatening and mandates revascularization. This study aimed to assess how patients rate the importance of particular features of coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI), how this determines their preference for a particular treatment strategy, and whether particular personality characteristics influence this preference.

Methods And Results: In total, 1145 patients who visited the outpatient clinic of the Erasmus Medical Center for stable coronary artery disease were asked to complete a case vignette-questionnaire on a hypothetical significant LM stenosis amenable to PCI or CABG.

View Article and Find Full Text PDF