Publications by authors named "Peter Krutzik"

The advent of time-of-flight mass cytometry (CyTOF) has enabled high dimensional and unbiased examination of the immune system to simultaneous interrogate a multitude of parameters and gain a better understanding of immunologic data from clinical trial samples. Here we describe the development and validation of a 33-marker mass cytometry workflow for measuring gastrointestinal (GI) trafficking peripheral blood mononuclear cells (PBMCs) in patients with celiac disease (CeD). This panel builds upon identification of well-characterized immune cells and expands to include markers modulated in response to gluten challenge in patients with CeD.

View Article and Find Full Text PDF

Background: Cryopreserved human peripheral blood mononuclear cells (PBMCs) are a commonly used sample type for a variety of immunological assays. Many factors can affect the quality of PBMCs, and careful consideration and validation of an appropriate PBMC isolation and cryopreservation method is important for well-designed clinical studies. A major point of divergence in PBMC isolation protocols is the collection of blood, either directly into vacutainers pre-filled with density gradient medium or the use of conical tubes containing a porous barrier to separate the density gradient medium from blood.

View Article and Find Full Text PDF

As antiviral drug resistance develops and new viruses emerge there is a pressing need to develop strategies to rapidly develop antiviral therapeutics. Here we use phospho-specific flow cytometry to assess perturbations of many different cellular signaling pathways during treatment with drug combinations that are highly effective in blocking Herpes simplex virus type 1 (HSV-1) infection. We discovered two antiviral drug combinations act on distinct signaling pathways, either STAT1 or S6 phosphorylation, to block HSV-1 infection.

View Article and Find Full Text PDF

The success of immunotherapy has led to a myriad of clinical trials accompanied by efforts to gain mechanistic insight and identify predictive signatures for personalization. However, many immune monitoring technologies face investigator bias, missing unanticipated cellular responses in limited clinical material. We present here a mass cytometry (CyTOF) workflow for standardized, systems-level biomarker discovery in immunotherapy trials.

View Article and Find Full Text PDF

Cytokine and growth-factor ligands typically signal through homo- or hetero-dimeric cell surface receptors via Janus Kinase (JAK/TYK), or Receptor Tyrosine Kinase (RTK)-mediated trans-phosphorylation. However, the number of receptor dimer pairings occurring in nature is limited to those driven by natural ligands encoded within our genome. We have engineered synthethic cytokines (synthekines) that drive formation of cytokine receptor dimer pairings that are not formed by endogenous cytokines and that are not found in nature, and which activate distinct signaling programs.

View Article and Find Full Text PDF

Most cell-surface receptors for cytokines and growth factors signal as dimers, but it is unclear whether remodeling receptor dimer topology is a viable strategy to "tune" signaling output. We utilized diabodies (DA) as surrogate ligands in a prototypical dimeric receptor-ligand system, the cytokine Erythropoietin (EPO) and its receptor (EpoR), to dimerize EpoR ectodomains in non-native architectures. Diabody-induced signaling amplitudes varied from full to minimal agonism, and structures of these DA/EpoR complexes differed in EpoR dimer orientation and proximity.

View Article and Find Full Text PDF

To determine critical host factors involved in HIV-1 replication, a dominant effector genetics approach was developed to reveal signaling pathways on which HIV-1 depends for replication. A large library of short peptide aptamers was expressed via retroviral delivery in T cells. Peptides that interfered with T cell activation-dependent processes that might support HIV-1 replication were identified.

View Article and Find Full Text PDF

Mass cytometry facilitates high-dimensional, quantitative analysis of the effects of bioactive molecules on human samples at single-cell resolution, but instruments process only one sample at a time. Here we describe mass-tag cellular barcoding (MCB), which increases mass cytometry throughput by using n metal ion tags to multiplex up to 2n samples. We used seven tags to multiplex an entire 96-well plate, and applied MCB to characterize human peripheral blood mononuclear cell (PBMC) signaling dynamics and cell-to-cell communication, signaling variability between PBMCs from eight human donors, and the effects of 27 inhibitors on this system.

View Article and Find Full Text PDF

This protocol describes methods for monitoring intracellular phosphorylation-dependent signaling events on a single-cell basis. This approach measures cell signaling by treating cells with exogenous stimuli, fixing cells with formaldehyde, permeabilizing with methanol, and then staining with phospho-specific antibodies. Thus, cell signaling states can be determined as a measure of how cells interact with their environment.

View Article and Find Full Text PDF

Type I Interferons (IFNs) are important cytokines for innate immunity against viruses and cancer. Sixteen human type I IFN variants signal through the same cell-surface receptors, IFNAR1 and IFNAR2, yet they can evoke markedly different physiological effects. The crystal structures of two human type I IFN ternary signaling complexes containing IFNα2 and IFNω reveal recognition modes and heterotrimeric architectures that are unique among the cytokine receptor superfamily but conserved between different type I IFNs.

View Article and Find Full Text PDF

Flow cytometry is an essential tool for dissecting the functional complexity of hematopoiesis. We used single-cell "mass cytometry" to examine healthy human bone marrow, measuring 34 parameters simultaneously in single cells (binding of 31 antibodies, viability, DNA content, and relative cell size). The signaling behavior of cell subsets spanning a defined hematopoietic hierarchy was monitored with 18 simultaneous markers of functional signaling states perturbed by a set of ex vivo stimuli and inhibitors.

View Article and Find Full Text PDF

Fluorescent cell barcoding (FCB) enables high throughput, high content flow cytometry by multiplexing samples prior to staining and acquisition on the cytometer. Individual cell samples are barcoded, or labeled, with unique signatures of fluorescent dyes so that they can be mixed together, stained, and analyzed as a single sample. By mixing samples prior to staining, antibody consumption is typically reduced 10- to 100-fold.

View Article and Find Full Text PDF

Phospho-specific flow cytometry, or phospho flow, measures the phosphorylation state of intracellular proteins at the single cell level. Many phosphorylation events can be analyzed simultaneously in each cell, along with cell surface markers, enabling complex biochemical signaling networks to be resolved in heterogeneous cell populations. The method has been applied to many diverse areas of biology, including the characterization of signaling pathways in normal immune responses to antigenic stimulation and microbial challenge, alteration of signaling networks that occur in cancer and autoimmune diseases, and high-throughput, high-content drug discovery.

View Article and Find Full Text PDF

Intracellular flow cytometry permits quantitation of diverse molecular targets at the single-cell level. However, limitations in detection sensitivity inherently restrict the method, sometimes resulting in the inability to measure proteins of very low abundance or to differentiate cells expressing subtly different protein concentrations. To improve these measurements, an enzymatic amplification approach called tyramide signal amplification (TSA) was optimized for assessment of intracellular kinase cascades.

View Article and Find Full Text PDF

Vaccinia immunization was pivotal to successful smallpox eradication. However, the early immune responses that distinguish poxvirus immunization from pathogenic infection remain unknown. To address this, we developed a strategy to map the activation of key signaling networks in vivo and applied this approach to define and compare the earliest signaling events elicited by immunizing (vaccinia) and lethal (ectromelia) poxvirus infections in mice.

View Article and Find Full Text PDF

Cytobank is a Web-based application for storage, analysis, and sharing of flow cytometry experiments. Researchers use a Web browser to log in and use a wide range of tools developed for basic and advanced flow cytometry. In addition to providing access to standard cytometry tools from any computer, Cytobank creates a platform and community for developing new analysis and publication tools.

View Article and Find Full Text PDF

Systemic lupus erythematosus (SLE) is a complex autoimmune disease of unknown etiology that involves multiple interacting cell types driven by numerous cytokines and autoimmune epitopes. Although the initiating events leading to SLE pathology are not understood, there is a growing realization that dysregulated cytokine action on immune cells plays an important role in promoting the inflammatory autoimmune state. We applied phospho-specific flow cytometry to characterize the extent to which regulation of cytokine signal transduction through the STAT family of transcription factors is disturbed during the progression of SLE.

View Article and Find Full Text PDF

An early reaction of CD4(+) T lymphocytes to Ag is the production of cytokines, notably IL-2. To detect cytokine-dependent responses, naive Ag-specific T cells were stimulated in vivo and the presence of phosphorylated STAT5 molecules was used to identify the cell populations responding to IL-2. Within hours of T cell priming, IL-2-dependent STAT5 phosphorylation occurred primarily in Foxp3(+) regulatory T cells.

View Article and Find Full Text PDF

Flow cytometry has emerged as a powerful tool for quantitative, single-cell analysis of both surface markers and intracellular antigens, including phosphoproteins and kinase signaling cascades, with the flexibility to process hundreds of samples in multiwell plate format. Quantitative flow cytometric analysis is being applied in many areas of biology, from the study of immunology in animal models or human patients to high-content drug screening of pharmacologically active compounds. However, these experiments generate thousands of data points per sample, each with multiple measured parameters, leading to data management and analysis challenges.

View Article and Find Full Text PDF

This protocol describes methods for monitoring intracellular phosphorylation-dependent signaling events on a single-cell basis. This approach measures cell signaling by treating cells with exogenous stimuli, fixing cells with formaldehyde, permeabilizing with methanol, and then staining with phospho-specific antibodies. Thus, cell signaling states can be determined as a measure of how cells interact with their environment.

View Article and Find Full Text PDF

Drug screening is often limited to cell-free assays involving purified enzymes, but it is arguably best applied against systems that represent disease states or complex physiological cellular networks. Here, we describe a high-content, cell-based drug discovery platform based on phosphospecific flow cytometry, or phosphoflow, that enabled screening for inhibitors against multiple endogenous kinase signaling pathways in heterogeneous primary cell populations at the single-cell level. From a library of small-molecule natural products, we identified pathway-selective inhibitors of Jak-Stat and MAP kinase signaling.

View Article and Find Full Text PDF

Flow cytometry allows high-content, multiparameter analysis of single cells, making it a promising tool for drug discovery and profiling of intracellular signaling. To add high-throughput capacity to flow cytometry, we developed a cell-based multiplexing technique called fluorescent cell barcoding (FCB). In FCB, each sample is labeled with a different signature, or barcode, of fluorescence intensity and emission wavelengths, and mixed with other samples before antibody staining and analysis by flow cytometry.

View Article and Find Full Text PDF

We generated a sequential reporter-enzyme luminescence (SRL) technology for in vivo detection of beta-galactosidase (beta-gal) activity. The substrate, a caged D-luciferin-galactoside conjugate, must first be cleaved by beta-gal before it can be catalyzed by firefly luciferase (FLuc) to generate light. As a result, luminescence is dependent on beta-gal activity.

View Article and Find Full Text PDF

Here we present phospho-specific flow cytometry as a new tool for drug discovery with applications throughout the drug development pipeline, from target identification to library screening, disease model assessment and clinical screening and diagnostics. The single cell, multiparameter nature of flow cytometry generates high-content datasets, and current improvements in the technology are rapidly increasing its high-throughput capacity, making it a valuable platform in modern drug discovery.:

View Article and Find Full Text PDF

The immune system is a multitiered network that at the first level uses changes to intracellular signaling proteins to commit cells to determined fates. At the second tier, cells interact with one another via specifically expressed surface receptors and their cognate signaling molecules. At the third level, the local environments of immune cells change the outcomes of intracellular signaling pathways and thereby the role of cells during immune challenge.

View Article and Find Full Text PDF