Publications by authors named "Peter Faulhaber"

We evaluated the potential differences of a digital positron-emission tomography (PET) prototype equipped with photon-counting detectors (D-PET, Philips Healthcare, Cleveland, Ohio, USA) in tumor volume delineation compared with the analog Gemini TF PET system (A-PET, Philips). Eleven oncologic patients first underwent clinical fluorodeoxyglucose (FDG) PET/computed tomography (CT) on A-PET. The D-PET ring was then inserted between the PET and CT scanner of A-PET and the patient was scanned for the second time.

View Article and Find Full Text PDF

Background And Purpose: To compare the utility of quantitative PET/MRI, dynamic susceptibility contrast (DSC) perfusion MRI (pMRI), and PET/CT in differentiating radiation necrosis (RN) from tumor recurrence (TR) in patients with treated glioblastoma multiforme (GBM).

Methods: The study included 24 patients with GBM treated with surgery, radiotherapy, and temozolomide who presented with progression on imaging follow-up. All patients underwent PET/MRI and pMRI during a single examination.

View Article and Find Full Text PDF

The future clinical use of the combination of positron emission tomography (PET) with 2-Fluoro[F-18]-2-Deoxy-d-Glucose (FDG)and MRI is still unclear. If a patient requires a PET and breast DCE-MRI for staging purposes, both scans can be done in the same visit. In the breast, DCE-MRI is better at lesion detection (sensitivity), margin evaluation, and has a higher specificity than CT.

View Article and Find Full Text PDF

A 59-year-old man with history of multiple sclerosis and residual sensory and motor dysfunction presented with progressive lower-extremity weakness, ataxic gait, and intermittent urinary incontinence. Brain MRI demonstrated volume loss with disproportionate ventricular dilatation, but no evidence of infarction or abnormal enhancement. Radionuclide cisternography showed early and persistent ventricular reflux, poor progression of radiopharmaceutical over convexities, and delayed clearance in a pattern consistent with normal pressure hydrocephalus.

View Article and Find Full Text PDF

The objective of this study was to assess the ability of a quantitative software-aided approach to improve the diagnostic accuracy of F FDG PET for Alzheimer's dementia over visual analysis alone. Twenty normal subjects (M:F-12:8; mean age 80.6 years) and twenty mild AD subjects (M:F-12:8; mean age 70.

View Article and Find Full Text PDF

Purpose: To retrospectively review post-treatment (post-tx) FDG-PET/CT scans in patients with advanced head and neck squamous cell carcinoma (HNSCC) and known p16 status, treated with definitive (chemo)radiation (RT).

Methods: A total of 108 eligible patients had N2A or greater HNSCC treated with chemoRT from August 1, 2008, to February 28, 2015, with post-tx PET/CT within 6 months after RT. Kaplan-Meier curves, log-rank statistics, and Cox proportional hazards regression were used for statistical analysis.

View Article and Find Full Text PDF

Unlabelled: We report our initial clinical experience for image quality and diagnostic performance of a digital PET prototype scanner with time-of-flight (DigitalTF), compared with an analog PET scanner with time-of-flight (GeminiTF PET/CT).

Methods: Twenty-one oncologic patients, mean age 58 y, first underwent clinical (18)F-FDG PET/CT on the GeminiTF. The scanner table was then withdrawn while the patient remained on the table, and the DigitalTF was inserted between the GeminiTF PET and CT scanner.

View Article and Find Full Text PDF

Metastatic melanoma is a deadly disease with a 5-year survival rate lower than 20%. In 2011, ipilimumab, a fully humanized antibody that binds to cytotoxic T-lymphocyte-associated antigen 4 (CTLA4) was approved by the US Food and Drug Administration based on improved survival in a pivotal trial. CTLA4 is a molecule on cytotoxic T-lymphocytes that plays a critical role in attenuating immune responses.

View Article and Find Full Text PDF

Positron emission tomography/magnetic resonance imaging (PET/MRI) leverages the high soft-tissue contrast and the functional sequences of MR with the molecular information of PET in one single, hybrid imaging technology. This technology, which was recently introduced into the clinical arena in a few medical centers worldwide, provides information about tumor biology and microenvironment. Studies on indirect PET/MRI (use of positron emission tomography/computed tomography (PET/CT) images software fused with MRI images) have already generated interesting preliminary data to pave the ground for potential applications of PET/MRI.

View Article and Find Full Text PDF

PET/MRI is an evolving hybrid imaging modality which combines the inherent strengths of MRIs soft-tissue and contrast resolution and PETs functional metabolic capabilities. Bone and soft-tissue sarcoma are a relatively rare tumor entity, relying on MRI for local staging and often on PET/CT for lymph node involvement and metastatic spread evaluation. The purpose of this article is to demonstrate the successful use of PET/MRI in two sarcoma patients.

View Article and Find Full Text PDF

Purpose: Sentinel lymph node (SLN) biopsy is instrumental in staging and treatment of cutaneous melanoma. SPECT/CT, single-photon emission computed tomography (SPECT) integrated with computed tomography (CT), increases the accuracy of SLN mapping to improve surgical planning. SPECT/CT can correct for signal scatter to prevent masking, which is especially common in the head and neck.

View Article and Find Full Text PDF

Cardiac metastasis in thyroid cancer is extremely rare. Iodine-131-d whole-body scan has been used widely to detect thyroid metastasis. However, in dedifferentiated cases, iodine scan has low diagnostic value particularly for diagnosing cardiac metastasis.

View Article and Find Full Text PDF

Magentic Resonance/positron emission tomography (PET) has been introduced recently for imaging of clinical patients. This hybrid imaging technology combines the inherent strengths of MRI with its high soft-tissue contrast and biological sequences with the inherent strengths of PET, enabling imaging of metabolism with a high sensitivity. In this article, we describe the initial experience of MR/PET in a clinical cancer center along with a review of the literature.

View Article and Find Full Text PDF

The purpose of this study is to systematically evaluate the usefulness of Positron emission tomography/Magnetic resonance imaging (PET/MRI) images in a clinical setting by assessing the image quality of Positron emission tomography (PET) images using a three-segment MR attenuation correction (MRAC) versus the standard CT attenuation correction (CTAC). We prospectively studied 48 patients who had their clinically scheduled FDG-PET/CT followed by an FDG-PET/MRI. Three nuclear radiologists evaluated the image quality of CTAC vs.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to compare and correlate standardized uptake values (SUV) derived from magnetic resonance attenuation correction (MRAC) with those derived from computed tomography attenuation correction (CTAC) in an oncology patient population.

Procedures: The HIPAA-compliant study was approved by the Internal Review Board and all subjects gave written informed consent prior to inclusion in the study. Forty patients (mean age 61 ± 15.

View Article and Find Full Text PDF

Objective: Cervical and vaginal cancers have virally-mediated or mutated defects in DNA damage repair responses, making these cancers sensible targets for ribonucleotide reductase inhibition during radiochemotherapy.

Methods: We conducted a phase II study evaluating 3× weekly 2-hour intravenous 3-aminopyridine-2-carboxaldehyde thiosemicarbazone (3-AP, 25 mg/m(2)) co-administered with 1× weekly intravenous cisplatin (40 mg/m(2)) and daily pelvic radiation (45 Gy) in women with stage I(B2)-IV(B) cervical (n=22) or stage II-IV vaginal (n=3) cancers. Brachytherapy followed (40 Gy).

View Article and Find Full Text PDF

This article discusses the role of FDG-PETederived parameters as prognostic indicators in patients with squamous cell carcinoma of the head and neck. The basic underlying biology of FDG-PET scans and the quantitative information that can be derived are discussed. A review of the literature is performed.

View Article and Find Full Text PDF

Each anatomic region of the head and neck has physiologic variations that can mimic a primary tumor or lymph node. Many of these variations can be recognized as reflecting benign lymphoid, salivary, brown fat, and muscular activity. A few artifacts are related to computed tomography (CT) attenuation.

View Article and Find Full Text PDF

The objective of the current article was to evaluate 2-[F]fluoro-2-deoxy-D-glucose F-FDG) as measured by positron emission tomography for delineation of abdominopelvic gross tumor volumes (GTV) for stereotactic body radiosurgery treatment (SBRT) of metastatic gynecologic cancers. A retrospective review of SBRT was conducted in 27 women with stage IV gynecologic cancers recurring in para-aortic lymph nodes. Robotic SBRT involved 2400 cGy in 3 consecutive 800 cGy daily fractions prescribed to a 3.

View Article and Find Full Text PDF

Hypothesis: A ratio of 3 months of posttherapy to pretherapy 2-[F]fluoro-2-deoxy-d-glucose positron emission tomography with computed tomography (F-FDG PET/CT) standard uptake values (SUVs) predicts progression-free survival after chemoradiation in patients with stages IB2 to IVA cervical cancer.

Methods: This retrospective review included 51 patients who received treatments of daily pelvic radiation and once-weekly cisplatin chemotherapy followed by brachytherapy. Posttherapy confirmatory surgical or cytologic pathology was done a median of 7 days after 3-month F-FDG PET/CT.

View Article and Find Full Text PDF

Purpose: To evaluate the accuracy and consistency of a gradient-based positron emission tomography (PET) segmentation method, GRADIENT, compared with manual (MANUAL) and constant threshold (THRESHOLD) methods.

Methods And Materials: Contouring accuracy was evaluated with sphere phantoms and clinically realistic Monte Carlo PET phantoms of the thorax. The sphere phantoms were 10-37 mm in diameter and were acquired at five institutions emulating clinical conditions.

View Article and Find Full Text PDF

We describe a 91-year-old woman with a clinical history of invasive ductal carcinoma of the breast diagnosed in 1991 who was admitted because of dizziness, poor appetite, and some swelling and tenderness over her cheeks. The patient's initial work up revealed a 5-cm well-demarcated hypodense solid lesion in her spleen with abnormally intense uptake on PET/CT scan raising suspicion for malignancy i.e.

View Article and Find Full Text PDF

Purpose: To evaluate the clinical utility of capromab pendetide imaging with single photon emission computed tomography coregistration with computed tomography (SPECT/CT) in primary prostate cancer (CaP) for pretreatment prognostic staging and localization of biologic target volumes (BTV) for individualized image-guided radiotherapy dose escalation (IGRT-DE).

Methods And Materials: Patients consecutively presenting for primary radiotherapy (February 1997 to December 2002), having a clinical diagnosis of localized CaP, were evaluated for tumor stage using conventional staging and SPECT/CT (N=239). Distant metastatic uptake (mets) were identified by SPECT/CT in 22 (9.

View Article and Find Full Text PDF