New conduction disorders remain a frequent complication in current transcatheter aortic valve replacement (TAVR) era. Left bundle branch block (LBBB) occurs early in about 20-30 % of TAVR-patients, persists at 1 month in about 35-45 % of cases and will likely remain thereafter. Third-degree atrioventricular block (AV3B) affects approximately 15 % of patients.
View Article and Find Full Text PDFBackground: Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve.
Methods: Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University.
Background: Calcium is a determinant of paravalvular leakage (PVL) after transcatheter aortic valve implantation (TAVI). This is based on a fixed contrast attenuation value while X-ray attenuation is patient-dependent and without considering frame expansion and PVL location. We examined the role of calcium in (site-specific) PVL after TAVI using a patient-specific contrast attenuation coefficient combined with frame expansion.
View Article and Find Full Text PDFBackground: Multislice computed tomography (MSCT) may reveal hypo-attenuated leaflet thickening (HALT) and/or reduced leaflet motion (RELM) in approximately 15 % of patients after transcatheter aortic valve replacement (TAVR). These supposedly thrombogenic phenomena may be associated with neurological events and increased transprosthetic gradients. It is unclear whether oral anticoagulant therapy -specifically a factor Xa inhibitor- could affect the incidence of HALT/RELM.
View Article and Find Full Text PDFBackground: The mechanically-expandable transcatheter valve is no longer commercially available, yet clinical and echocardiographic surveillance is imperative for thousands of patients who received transcatheter aortic valve implantation (TAVI) with this platform.
Aims: We aimed to determine the incidence and mechanism of bioprosthetic valve dysfunction (BVD) following TAVI with mechanically-expandable valves.
Methods: From 2013 to 2020, all 234 patients who underwent TAVI with the LOTUS valve were included.
Objectives: To study the safety and feasibility of a restrictive temporary-RV-pacemaker use and to evaluate the need for temporary pacemaker insertion for failed left ventricular (LV) pacing ability (no ventricular capture) or occurrence of high-degree AV-blocks mandating continuous pacing.
Background: Ventricular pacing remains an essential part of contemporary transcatheter aortic valve implantation (TAVI). A temporary-right-ventricle (RV)-pacemaker lead is the standard approach for transient pacing during TAVI but requires central venous access.
Objectives: The impact of large thrombus burden (LTB) on very long-term clinical outcomes in patients with ST-segment elevation myocardial infarction (STEMI) is unknown. We compared very long-term clinical outcomes in STEMI patients with either LTB or small thrombus burden (STB).
Methods: Between 2002 and 2004, thrombus burden (TB) was evaluated in consecutive patients with STEMI undergoing percutaneous coronary intervention (PCI).
We sought to assess the amount and distribution of force on the valve frame after transcatheter aortic valve replacement (TAVR) via patient-specific computer simulation. Patients successfully treated with the self-expanding Venus A-Valve and multislice computed tomography (MSCT) pre- and post-TAVR were retrospectively included. Patient-specific finite element models of the aortic root and prosthesis were constructed.
View Article and Find Full Text PDFSelecting patients with a high chance of endured benefit from transcatheter aortic valve implantation (TAVI) is becoming relevant with changing indications and increasing number of TAVI being performed. The aim of our study was to investigate the association of the multidimensional prognostic index (MPI) based on a comprehensive geriatric assessment (CGA) on survival. The TAVI Care & Cure program is a prospective, observational registry of patients referred for TAVI at the Erasmus MC University Medical Center.
View Article and Find Full Text PDFAims: Post-procedure conduction abnormalities (CA) remain a common complication of transcatheter aortic valve implantation (TAVI), highlighting the need for personalized prediction models. We used machine learning (ML), integrating statistical and mechanistic modelling to provide a patient-specific estimation of the probability of developing CA after TAVI.
Methods And Results: The cohort consisted of 151 patients with normal conduction and no pacemaker at baseline who underwent TAVI in nine European centres.
Objectives: To report on the experience with a selective prophylactic permanent pacemaker (PPx-PPM) implantation strategy in patients with pre-existing right bundle branch block (RBBB) undergoing transcatheter aortic valve replacement (TAVR).
Background: Pre-existing RBBB is an independent predictor for PPM after TAVR and has been linked to increased mortality.
Methods: Hospital patient flow and longer-term clinical endpoints were compared for TAVR patients with pre-existing RBBB treated in a period with and without selective PPx-PPM strategy (2013-2020).
Background: Functional mitral regurgitation (FMR) can be subclassified on the basis of its proportionality relative to left ventricular (LV) volume and function, indicating potential differences in underlying etiology. The aim of this study was to evaluate the association of FMR proportionality with FMR reduction, heart failure hospitalization and mortality after transcatheter edge-to-edge mitral valve repair (TEER).
Methods: This multicenter registry included 241 patients with symptomatic heart failure with reduced LV ejection fraction treated with TEER for moderate to severe or greater FMR.