The anthropogenic entry of organic micropollutants into the aquatic environment leads to a potential risk for drinking water resources and the drinking water itself. Therefore, sensitive screening analysis methods are needed to monitor the raw and drinking water quality continuously. Non-target screening analysis has been shown to allow for a more comprehensive investigation of drinking water processes compared to target analysis alone.
View Article and Find Full Text PDFSuspect and non-target screening based on the use of high-resolution mass spectrometry (HRMS) has become more common in water analysis over the past years. However, this only yields lists of features or suspects without quantitative information. To expand the use of HRMS data to a quantitative screening, we have developed and validated a simple and fast method for more than 140 micropollutants using ultra high-performance liquid chromatography coupled to traveling wave ion mobility quadrupole time-of-flight mass spectrometry (UPLC-IM-Q-TOF-MS).
View Article and Find Full Text PDFCollision cross section (CCS, Ω) values determined by ion mobility mass spectrometry (IM-MS) provide the study of ion shape in the gas phase and use of these as further identification criteria in analytical approaches. Databases of CCS values for a variety of molecules determined by different instrument types are available. In this study, the comparability of CCS values determined by a drift tube ion mobility mass spectrometer (DTIM-MS) and a traveling wave ion mobility mass spectrometer (TWIM-MS) was investigated to test if a common database could be used across IM techniques.
View Article and Find Full Text PDFWith regard to the Water Framework Directive (WFD) and the required investigation of the whole water sample including suspended particulate matter (SPM), a storage stability study was conducted to determine the suitable storage time and conditions of 21 organochlorine pesticides (OCPs) spiked in water samples and pre-concentrated on solid-phase extraction disks (SPE disks). Furthermore, this work demonstrates the behaviour of three different certified sediment reference materials (CRMs) contaminated with OCPs in water samples as well as loaded on SPE disks under different temperature conditions and storage time periods. Extracts collected on SPE disks were stored for 3, 14 and 30 days at both 4 °C and -18 °C in darkness covered in (a) freezer bags and (b) aluminum foil.
View Article and Find Full Text PDFInfiltration of treated wastewater (TWW) to recharge depleted aquifers, often referred to as managed aquifer recharge, is a solution to replenish groundwater resources in regions facing water scarcity. We present a mass balance approach to infer the amounts of five pharmaceuticals (carbamazepine, diclofenac, fenoprofen, gemfibrozil, and naproxen) degraded in column experiments based on concentrations of pharmaceuticals in the aqueous and solid (sorbed) phases. Column experiments were conducted under three different conditions: continuous infiltration, wetting and drying cycles, and wetting and drying cycles with elevated concentrations of antibiotics (which may reduce microbially aided degradation of other compounds).
View Article and Find Full Text PDFIn this study, 21 organochlorine pesticides (OCPs) were determined based on sample preparation using solid-phase extraction disks (SPE disks) coupled with programmable temperature vaporizer (PTV)-large-volume injection gas-chromatography mass spectrometry (LVI-GC-MS). The work includes a comprehensive testing scheme on the suitability of the method for routine analysis of surface and drinking water including suspended particulate matter (SPM) with regard to requirements derived from the European Water Framework Directive (WFD, Directive 2000/60/EC). SPM is an important reservoir for OCPs, which contributes to the transport of these compounds in the aquatic environment.
View Article and Find Full Text PDFA reliable quantification by LC-ESI-MS/MS as the most suitable analytical method for polar substances in the aquatic environment is usually hampered by matrix effects from co-eluting compounds, which are unavoidably present in environmental samples. The standard addition method (SAM) is the most appropriate method to compensate matrix effects. However, when performed manually, this method is too labour- and time-intensive for routine analysis.
View Article and Find Full Text PDFPolybrominated diphenyl ethers, polychlorinated biphenyls, polycyclic aromatic hydrocarbons and organochlorine pesticides in the low nanogram-per-litre range in water were enriched by solid-phase extraction (SPE) disks and their concentration determined by large-volume injection/gas chromatography-mass spectrometry (LVI/GC-MS). One advantage of using SPE disks in comparison with SPE cartridges is that suspended particulate matter (SPM) does not have to be separated prior to the enrichment step, which saves time and effort. To increase the sensitivity of the method, the SPE disk procedure was combined with LVI/GC-MS, which has not been reported so far for water analysis.
View Article and Find Full Text PDFSuspended particulate matter (SPM) often disturbs the analysis of surface water by conventional methods, such as liquid-liquid extraction (LLE) or solid phase extraction (SPE), caused by insufficient extraction or by plugging. Water and SPM are therefore often separately analysed, which is associated with high expenditure of time, work and costs. Hence, SPM is partly ignored, if the fraction of sorptively bound analytes is small compared to the total analyte concentration.
View Article and Find Full Text PDFThe development and validation of a sensitive and reliable detection method for the determination of two polar degradation products, desphenyl-chloridazon (DPC) and methyl-desphenyl-chloridazon (MDPC) in surface water, ground water and drinking water is presented. The method is based on direct large volume injection ultra-performance liquid chromatography electrospray tandem mass spectrometry. This simple but powerful analytical method for polar substances in the aquatic environment is usually hampered by varying matrix effects, depending on the nature of different water bodies.
View Article and Find Full Text PDFSolid-phase extraction (SPE) is a widespread and powerful sample preparation technique in many analytical areas. Many of the used methods reduce residual water during sample preparation by drying the phase material. Despite the importance of this step, hardly any study deals specifically with the drying process, and if so, only few aspects are mentioned.
View Article and Find Full Text PDFThis study provides the first pan-European reconnaissance of the occurrence of polar organic persistent pollutants in European ground water. In total, 164 individual ground-water samples from 23 European Countries were collected and analysed (among others) for 59 selected organic compounds, comprising pharmaceuticals, antibiotics, pesticides (and their transformation products), perfluorinated acids (PFAs), benzotriazoles, hormones, alkylphenolics (endocrine disrupters), Caffeine, Diethyltoluamide (DEET), and Triclosan. The most relevant compounds in terms of frequency of detection and maximum concentrations detected were DEET (84%; 454 ng/L), Caffeine (83%; 189 ng/L), PFOA (66%; 39 ng/L), Atrazine (56%; 253 ng/L), Desethylatrazine (55%; 487 ng/L), 1H-Benzotriazole (53%; 1032 ng/L), Methylbenzotriazole (52%; 516 ng/L), Desethylterbutylazine (49%; 266 ng/L), PFOS (48%, 135 ng/L), Simazine (43%; 127 ng/L), Carbamazepine (42%; 390 ng/L), nonylphenoxy acetic acid (NPE(1)C) (42%; 11 microg/L), Bisphenol A (40%; 2.
View Article and Find Full Text PDFThis study presents a fast, sensitive, and robust method for the determination of the polar pesticide degradation product N,N-dimethylsulfamide (DMS) in water based on ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). To provide a robust analysis method, the use of an internal standard for both natural waters and model water was examined in order to compensate for matrix effects. The relative standard deviation was found to be +/-15% (n = 10) and the limit of detection was 10 ng/L by direct injection in the UPLC-MS/MS system.
View Article and Find Full Text PDFThe European water framework directive (WFD) requires priority pollutants to be measured in the whole water sample and not only in the dissolved phase. However, it does not give clear definitions on how to achieve this. To overcome this limitation, a new methodology of sample preparation procedure for the analysis of polycyclic aromatic hydrocarbons on the basis of extraction disks is introduced here.
View Article and Find Full Text PDF