This paper describes in detail a compact (2U format) telescope operating in the extreme ultraviolet range for studying the solar corona at a wavelength of 17.14 nm. The telescope objective has been built according to the Ritchey-Chrétien scheme with the following parameters: effective focal length of 381.
View Article and Find Full Text PDFOne of the challenges in the development of patient-specific models of cardiac arrhythmias for clinical applications has been accounting for myocardial fiber organization. The fiber varies significantly from heart to heart, but cannot be directly measured in live tissue. The goal of this paper is to evaluate in-silico the accuracy of left atrium activation maps produced by a fiber-independent (isotropic) model with tuned diffusion coefficients, compares to a model incorporating myocardial fibers with the same geometry.
View Article and Find Full Text PDFOver the past two decades there has been a steady trend towards the development of realistic models of cardiac conduction with increasing levels of detail. However, making models more realistic complicates their personalization and use in clinical practice due to limited availability of tissue and cellular scale data. One such limitation is obtaining information about myocardial fiber organization in the clinical setting.
View Article and Find Full Text PDFOver the past two decades there has been a steady trend towards the development of realistic models of cardiac conduction with increasing levels of detail. However, making models more realistic complicates their personalization and use in clinical practice due to limited availability of tissue and cellular scale data. One such limitation is obtaining information about myocardial fiber organization in the clinical setting.
View Article and Find Full Text PDFBackground: Catheter ablation therapy involving isolation of pulmonary veins (PVs) from the left atrium is performed to terminate atrial fibrillation (AF). Unfortunately, standalone PV isolation procedure has shown to be a suboptimal success with AF continuation or recurrence. One reason, especially in patients with persistent or high-burden paroxysmal AF, is known to be due to the formation of repeating-pattern AF sources with a meandering core inside the atria.
View Article and Find Full Text PDFCatheter ablation therapy involving isolation of pulmonary veins (PVs) remains the cornerstone procedure to treat AF. However, due to the sub-optimal success rates of PV isolation, there is a need for new ablation techniques to locate AF ablation targets known as rotors, outside of the PVs. In this paper, we developed a novel rotor-mapping algorithm that uses a conventional diagnostic catheter, Lasso, to locate a rotor source.
View Article and Find Full Text PDFWe studied the effect of LPS on the state of stress-marker organs in rats at various periods after a single exposure to long-term stress on the model of 24-h immobilization. The animals were intraperitoneally injected with LPS in a dose of 100 μg/kg immediately after the negative emotiogenic exposure. Changes in physiological parameters were evaluated 3 h, 1 day, and 8 days after immune stimulation.
View Article and Find Full Text PDFPurpose: Multi-polar diagnostic catheters are used to construct the 3D electro-anatomic mapping of the atrium during atrial fibrillation (AF) ablation procedures; however, it remains unclear how to use the electrograms recorded by these catheters to locate AF-driving sites known as focal and rotor source types. The purpose of this study is to present the first algorithm to iteratively navigate a circular multi-polar catheter to locate AF focal and rotor sources without the need to map the entire atria.
Methods: Starting from an initial location, the algorithm, which was blinded to the location and type of the AF source, iteratively advanced a Lasso catheter based on its electrogram characteristics.
Introduction: Targeting repeating-pattern atrial fibrillation (AF) sources (reentry or focal drivers) can help in patient-specific ablation therapy for AF; however, the development of reliable and accurate tools for locating such sources remains a major challenge. We describe iterative catheter navigation (ICAN) algorithm to locate AF drivers using a conventional circular Lasso catheter.
Methods And Results: At each step, the algorithm analyzes 10 bipolar electrograms recoded at a given catheter location and the history of previous catheter movements to determine if the source is inside the catheter loop.
Locating atrial fibrillation (AF) rotor sources can help target ablation therapy for AF. Our aim was to develop a catheter-tracking algorithm to locate AF rotor sources using a conventional 20-electrode circular catheter. We simulated rotor-driven arrhythmias in homogeneous and fibrotic human atrial tissue and evaluated the algorithm for different initial catheter positions.
View Article and Find Full Text PDFWe describe a method to accurately measure the light scattering model parameters from forward-directed flux (FDF) measurements carried out with a fiber-optic probe (optrode). Improved determination of light scattering parameters will, in turn, permit better modeling and interpretation of optical mapping in the heart using voltage-sensitive dyes. Using our optrode-based system, we carried out high spatial resolution measurements of FDF in intact and homogenized cardiac tissue, as well as in intralipid-based tissue phantoms.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2016
Simulations are excellent tools for assessing new therapeutic strategies and are often conducted before implementing new therapy options in a clinical practice. For patients suffering from a heart arrhythmia, the main source of information comes from an intracardiac catheter. One of the common catheters is a Lasso multi-pole diagnostic catheter, which is a catheter that has 20 electrodes in a circular pattern.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2016
Locating atrial fibrillation (AF) focal and rotor sources can help improve target ablation therapy for AF. However, it remains unclear how to use the information provided by multi-polar diagnostic catheters (MPDC) to locate AF sources. Our aim was to develop a catheter-guidance algorithm to locate AF focal and rotor sources using a conventional MPDC.
View Article and Find Full Text PDFAtrial fibrillation (AF) is the most common arrhythmia in USA with more than 2.3 million people affected annually. Catheter ablation procedure is a method for treatment of AF, which involves 3D electroanatomic mapping of the patient's left atrium (LA) by maneuvering a conventional multipolar diagnostic catheter (MPDC) along the LA endocardial surface after which pulmonary vein (PV) isolation is performed, thus eliminating the AF triggers originating from the PVs.
View Article and Find Full Text PDFThis chapter reviews the major milestones and scientific achievements facilitated by optical imaging of the action potential in the heart over more than four decades since its introduction. We discuss the limitations of this technique, which sometimes are not fully recognized; the unresolved issues, such as motion artifacts, and the newest developments and future directions.
View Article and Find Full Text PDFWe explore the shape and the dynamics of scroll-wave filaments in excitable media with an abruptly changing diffusion tensor, important for cardiac applications. We show that, similar to a beam of light, the filament refracts at the boundary separating domains with different diffusion. We derive the laws of filament refraction and test their validity in computational experiments.
View Article and Find Full Text PDFThis study investigates the development of the spatiotemporal pattern of action potential alternans during acute regional ischemia. Experiments were carried out in isolated Langendorff-perfused rabbit heart using a combination of optical mapping and microelectrode recordings. The alternans pattern significantly changed over time and had a biphasic character reaching maximum at 6-9 min after occlusion.
View Article and Find Full Text PDFCirc Arrhythm Electrophysiol
June 2015
Background: The electric response of myocardial tissue to periodic field stimuli has attracted significant attention as the basis for low-energy antifibrillation pacing, potentially more effective than traditional single high-energy shocks. In conventional models, an electric field produces a highly nonuniform response of the myocardial wall, with discrete excitations, or hot spots (HS), occurring at cathodal tissue surfaces or large coronary vessels. We test this prediction using novel 3-dimensional tomographic optical imaging.
View Article and Find Full Text PDFComput Math Methods Med
August 2014
Embryonic heart morphogenesis (EHM) is a complex and dynamic process where the heart transforms from a single tube into a four-chambered pump. This process is of great biological and clinical interest but is still poorly understood for two main reasons. On the one hand, the existing imaging modalities for investigating EHM suffered from either limited penetration depth or limited spatial resolution.
View Article and Find Full Text PDFVoltage-sensitive fluorescent dyes have become a major tool in cardiac and neuro-electrophysiology. Achieving high signal-to-noise ratios requires increased illumination intensities, which may cause photobleaching and phototoxicity. The optimal range of illumination intensities varies for different dyes and must be evaluated individually.
View Article and Find Full Text PDFAnchoring of spiral and scroll waves in excitable media has attracted considerable interest in the context of cardiac arrhythmias. Here, by bombarding inclusions with drifting spiral and scroll waves, we explore the forces exerted by inclusions onto an approaching spiral and derive the equations of motion governing spiral dynamics in the vicinity of inclusion. We demonstrate that these forces nonmonotonically depend on distance and can lead to complex behavior: (a) anchoring to small but circumnavigating larger inclusions; (b) chirality-dependent anchoring.
View Article and Find Full Text PDFOptical mapping has become an indispensible tool for studying cardiac electrical activity. However, due to the three-dimensional nature of the optical signal, the optical upstroke is significantly longer than the electrical upstroke. This raises the issue of how to accurately determine the activation time on the epicardial surface.
View Article and Find Full Text PDFCardiac arrhythmias are often triggered by ectopic membrane depolarization originating deep inside the myocardial wall. Here we propose a new method utilizing a novel near-infrared voltage-sensitive fluorescent dye DI-4-ANBDQBS to determine the three-dimensional (3D) coordinates of the sources of such depolarization. We tested the method in live preparations of pig left and right ventricular myocardium (thickness 8-18 mm) and phantoms imitating the optical properties of myocardial tissue.
View Article and Find Full Text PDFPhys Rev E Stat Nonlin Soft Matter Phys
September 2010
We investigate anchored scroll-wave filaments in an excitable medium whose diffusivity matrix, including its determinant, is spatially nonuniform. The study is motivated by cardiological applications where scroll-wave behavior in the presence of diffusivity gradients is believed to play an important role in the development of severe arrhythmias. A diffusivity gradient is expected to make the filament drift, unless drift is prevented ("frustrated") by anchoring to localized defects in the propagation medium.
View Article and Find Full Text PDF