Publications by authors named "Persichetti G"

We report an optofluidic hybrid silicon-polymer planar ring resonator with integrated microfluidic channels for efficient liquid delivery. The device features a planar architecture of intersecting liquid-core waveguides and microfluidic channels. A low-loss integration of microfluidic channels is accomplished by exploiting the interference pattern created by the self-imaging effect in the multimode interference-based coupler waveguides.

View Article and Find Full Text PDF

The present paper describes a compact point of care (POC) optical device for therapeutic drug monitoring (TDM). The core of the device is a disposable plastic chip where an immunoassay for the determination of immunosuppressants takes place. The chip is designed in order to have ten parallel microchannels allowing the simultaneous detection of more than one analyte with replicate measurements.

View Article and Find Full Text PDF

A full polymeric optofluidic Fabry-Perot (FP) resonator with a high quality factor (Q) is proposed and tested. The device is based on multilayer optical polymeric films that act as high reflectivity interference mirrors. The all-polymeric laminated structure avoids any deposition or etching process, simplifying the fabrication procedure while retaining a high quality optical surface.

View Article and Find Full Text PDF

In this Letter, we demonstrate the possibility to measure the refractive index of a liquid, using the stimulating Brillouin scattering in a 3-cm-long side-polished optical fiber. In addition, we show that by depositing a high-refractive index layer on the polished surface the sensitivity of the Brillouin frequency shift (BFS) can be increased due to a higher penetration of the evanescent field in the outer medium. Experiments show a maximum BFS change of about 11 MHz when varying the refractive index of the external medium from 1 (air) to 1.

View Article and Find Full Text PDF

Whispering Gallery Mode (WGM) micro-resonators like microspheres or microtoroids are typically used as high-Q cavity substrate on which a functional film coating is deposited. In order to exploit the coating properties a critical step is the efficient excitation of WGMs mainly contained inside the deposited layer. We developed a simple method able to assess whether or not these modes are selectively excited.

View Article and Find Full Text PDF

A multifunctional lab-on-a-chip platform for spectroscopic analysis of liquid samples based on an optofluidic jet waveguide is reported. The optofluidic detection scheme is achieved through the total internal reflection arising in a liquid jet of only 150 μm diameter, leading to highly efficient signal excitation and collection. This results in an optofluidic chip with an alignment-free spectroscopic detection scheme, which avoids any background from the sample container.

View Article and Find Full Text PDF

In this paper, we report the study on a new protocol for the immobilization process of antigen/antibody assay on SU-8 layers by oxygen plasma treatment. Plasma treatments, at different plasma powers and for different duration times, are performed and their effects on immobilization efficiency are studied. The chemical properties and the surface morphology of SU-8 before and after the functionalization and immobilization of (IgG) are then verified by Raman spectroscopy and atomic force microscopy (AFM).

View Article and Find Full Text PDF

The feasibility of water monitoring by Raman spectroscopy with a portable optofluidic system for in-situ applications has been successfully demonstrated. In the proposed approach, the sample under analysis is injected into a capillary nozzle in order to produce a liquid jet that acts as an optical waveguide. This jet waveguide provides an effective strategy to excite and collect the Raman signals arising from water contaminants due to the high refractive index difference between air and water.

View Article and Find Full Text PDF

In this paper, we introduce a liquid core antiresonant reflecting optical waveguide (ARROW) as a novel optofluidic device that can be used to create innovative and highly functional microsensors. Liquid core ARROWs, with their dual ability to guide the light and the fluids in the same microchannel, have shown great potential as an optofluidic tool for quantitative spectroscopic analysis. ARROWs feature a planar architecture and, hence, are particularly attractive for chip scale integrated system.

View Article and Find Full Text PDF

A micro flow cytometer with a single step 3D hydrodynamic flow focusing has been developed. The proposed design is capable to create a single-file particle stream that is self-aligned with an integrated optical fiber-based detection system, regardless of the flow rate ratio between the focusing and core liquids. The design approach provides the ability to adjust the stream size while keeping the position of the focused stream centered with respect to the focusing channel.

View Article and Find Full Text PDF

Optofluidics is a relatively young research field able to create a tight synergy between optics and micro/nano-fluidics. The high level of integration between fluidic and optical elements achievable by means of optofluidic approaches makes it possible to realize an innovative class of sensors, which have been demonstrated to have an improved sensitivity, adaptability and compactness. Many developments in this field have been made in the last years thanks to the availability of a new class of low cost materials and new technologies.

View Article and Find Full Text PDF

A hybrid silicon-poly(dimethysiloxane) (PDMS) optofluidic platform for lab-on-a-chip applications is proposed. A liquid-core waveguide with a self-aligned solid-core waveguide and a microfluidic device are integrated with a multilayer approach, resulting in a three-dimensional device assembly. The optofluidic layer was fabricated with a hybrid silicon-polymer technology, whereas the microfluidic layer was fabricated with a soft lithography technique.

View Article and Find Full Text PDF

A novel spectroscopic sensor based on an optofluidic liquid jet waveguide is presented. In this device, a liquid jet waveguide is generated with the solution under analysis. This stream, exploiting total internal reflection, acts as an optical waveguide confining the autofluorescence light produced by chemical or biological samples when opportunely excited.

View Article and Find Full Text PDF

An optofluidic water-jet waveguide on chip for fluorescence analysis is presented. A high-speed water stream produced by means of a microchannel acts at the same time as the solution to analyze and as the collecting optical waveguide. The absence of solid walls and the very optically smooth surface of the liquid stream permits a strong increase of the signal-to-noise ratio.

View Article and Find Full Text PDF

The gravitational-wave (GW) sky may include nearby pointlike sources as well as stochastic backgrounds. We perform two directional searches for persistent GWs using data from the LIGO S5 science run: one optimized for pointlike sources and one for arbitrary extended sources. Finding no evidence to support the detection of GWs, we present 90% confidence level (C.

View Article and Find Full Text PDF

We report an application of Kalman filtering to the inverted pendulum (IP) of the Virgo gravitational wave interferometer. Using subspace method system identification techniques, we calculated a linear mechanical model of Virgo IP from experimental transfer functions. We then developed a Kalman filter, based on the obtained state space representation, that estimates from open loop time domain data, the state variables of the system.

View Article and Find Full Text PDF

In-vacuum Faraday isolators (FIs) are used in gravitational wave interferometers to prevent the disturbance caused by light reflected back to the input port from the interferometer itself. The efficiency of the optical isolation is becoming more critical with the increase of laser input power. An in-vacuum FI, used in a gravitational wave experiment (Virgo), has a 20 mm clear aperture and is illuminated by an almost 20 W incoming beam, having a diameter of about 5 mm.

View Article and Find Full Text PDF

A stochastic background of gravitational waves is expected to arise from a superposition of a large number of unresolved gravitational-wave sources of astrophysical and cosmological origin. It should carry unique signatures from the earliest epochs in the evolution of the Universe, inaccessible to standard astrophysical observations. Direct measurements of the amplitude of this background are therefore of fundamental importance for understanding the evolution of the Universe when it was younger than one minute.

View Article and Find Full Text PDF

We describe a model evaluating changes in the optical isolation of a Faraday isolator when passing from air to vacuum in terms of different thermal effects in the crystal. The changes are particularly significant in the crystal thermal lensing (refraction index and thermal expansion) and in its Verdet constant and can be ascribed to the less efficient convection cooling of the magneto-optic crystal of the Faraday isolator. An isolation decrease by a factor of 10 is experimentally observed in a Faraday isolator that is used in a gravitational wave experiment (Virgo) with a 10 W input laser when going from air to vacuum.

View Article and Find Full Text PDF

As the unified training body for osteopathic physicians specializing in dermatology, the American Osteopathic College of Dermatology (AOCD) sponsors 18 dermatology residency programs that integrate academic training (focusing on the core of basic medical sciences) with clinical instruction (emphasizing specialized diagnostic and laboratory techniques and the high-level performance of all dermatologic and surgical procedures) to engender the ability to provide superior, specialized dermatologic care. The board of directors of the American Academy of Dermatology (AAD) recommended passage of a bylaws amendment establishing a category of osteopathic fellow for those osteopathic physicians who are certified by the American Osteopathic Board of Dermatology; however, the AAD membership failed to adopt the amendment by the required two-thirds majority. Constitutional bylaws of both societies stress the importance of the goal of unification and representation of the specialty of dermatology.

View Article and Find Full Text PDF

Of concern with the use of preangled abutments on implants is the transmission of masticatory forces and the angle at which they occur. Nineteen endosseous implants were placed in two subhuman primates. After 6 months, to allow for osseointegration, the implants were fitted with preangled abutments of various degrees and restored with type IV alloy castings.

View Article and Find Full Text PDF