Skin homeostasis is strongly dependent on its hydration levels, making skin water content measurement vital across various fields, including medicine, cosmetology, and sports science. Noninvasive diagnostic techniques are particularly relevant for clinical applications due to their minimal risk of side effects. A range of optical methods have been developed for this purpose, each with unique physical principles, advantages, and limitations.
View Article and Find Full Text PDFBiochem Med (Zagreb)
February 2025
This case report investigates the occurrence of green discoloration in serum and citrate plasma samples collected from a male adult patient following a multivisceral organ transplant. In collected samples, it was necessary to investigate the influence of sample discoloration on the results of laboratory tests and to determine the appropriate approach to sample management. Hematology, coagulation and blood gas analysis showed no flags, but the biochemical lipemia index was susceptible to positive interference, necessitating dilution of the native sample.
View Article and Find Full Text PDFIntroduction: This study aimed to examine whether the Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) reference intervals for 19 commonly used biochemical assays (potassium, sodium, chloride, calcium, magnesium, inorganic phosphorous, glucose, urea, creatinine, direct and total bilirubin, C-reactive protein (CRP), total protein, albumin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma-glutamyl transferase (GGT), alkaline phosphatase (ALP) and lactate dehydrogenase (LD)) could be applied to the newborn population of one Croatian clinical hospital.
Materials And Methods: Reference interval verification was performed according to the CLSI EP28-A3c guidelines. Samples of healthy newborns were selected using the direct sampling method and analyzed on the Beckman Coulter AU680 biochemical analyzer.
Hemangioma, the predominant benign tumor occurring in infancy, exhibits a wide range of prognoses and associated outcomes. The accurate determination of prognosis through noninvasive imaging modalities holds essential importance in enabling effective personalized treatment strategies and minimizing unnecessary surgical interventions for individual patients. The present study focuses on advancing the personalized prognosis of hemangioma by leveraging noninvasive optical sensing technologies by the development of a novel rapid hyperspectral sensor (image collection in 5 s, lateral resolution of 10 μm) that is capable of quantifying hemoglobin oxygenation and vascularization dynamics during the course of tumor evolution.
View Article and Find Full Text PDFHematomas resulted from trauma are very common, and the efficacy of existing treatment techniques is limited. Phototherapy can be used to expedite healing and improve the appearance of the damaged tissue. Efficient phototherapy requires determination of chromophore composition in hematoma, which can be provided by the optoacoustic (OA) technique, as it combines high spatial resolution and optical contrast.
View Article and Find Full Text PDFPhys Chem Chem Phys
February 2023
Nowadays phototherapy is widely used for treatment of various diseases. However, efficient application of phototherapy requires an understanding of light interactions with main endogenous chromophores (, hemoglobin, bilirubin, and water) in tissue. In particular, bilirubin is the target chromophore in the treatment of neonatal jaundice, which is the most common disease affecting up to 80% of preterm infants.
View Article and Find Full Text PDFSkin water content monitoring is important for diagnostics and management of edema, dehydration, and other skin conditions as well as for cosmetic applications. Because optoacoustic (OA) technique has high (optical) contrast and (ultrasound) resolution and significant probing depth, it may be suitable for accurate, noninvasive water content monitoring in the skin. In this work we studied OA response from skin tissue phantoms and human wrist skin in the wavelength range from 1370 nm to 1650 nm using a novel, tunable OPO OA system.
View Article and Find Full Text PDFThe objective of this study was to evaluate the effects of in-feed clinoptilolite (CPL) on serum metabolic and antioxidative biomarkers, acute phase proteins and reproductive performance in cows during pregnancy and lactation. A total of 78 Holstein-Friesian cows were randomly assigned into two groups: the treatment group, cows fed CPL (n = 38) which received 50 g of powdered CPL twice a day from day 180 before parturition to day 60 postpartum; and the control group (n = 40). Blood samples were taken on days 180, 90, 60, 30 and 10 before parturition, on day of calving and on days 5, 12, 19, 26, 33, 40 and 60 postpartum, and were analysed for metabolic biomarkers: glucose, triglycerides, total cholesterol, high density lipoprotein cholesterol, non-esterified fatty acids, beta-hydroxybutyrate (BHB), antioxidative biomarkers and acute phase proteins: paraoxonase-1 (PON1), apolipoprotein A-I, haptoglobin (Hp) and serum amyloid A (SAA).
View Article and Find Full Text PDFBackground: Improving quality and patient safety in the medical biochemistry laboratory accredited according to the International Standard Organization (ISO 15189:2012) requires the patient-centered evaluation of errors based on the implementation of quality indicators (QIs) across the total testing process. Our main goal was to achieve quality improvement of the preanalytical process in an emergency laboratory which had the highest error rate using risk management principles.
Methods: Failure mode and effects analysis (FMEA) was applied to analyze predefined preanalytical QIs and score laboratory failures for the failure demerit value (FDV), probability of failure (PF) and probability of failure remedy (PFR).
Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety.
View Article and Find Full Text PDFHeat stress is a major factor contributing to low fertility of dairy cows with a great economic impact in dairy industry. Heat-stressed dairy cows usually have reduced nutrient intake, resulting in a higher degree of negative energy balance (NEB). The aim of this study was to investigate the seasonal thermal effect on lipid metabolism, antioxidant activity and reproductive performance in dairy cows.
View Article and Find Full Text PDFThe objective of this study was to evaluate metabolic disorders and oxidative stress in dairy heifers during the transition period. Possible relationships between lipid mobilisation indicators and oxidative stress markers were investigated as well. Nineteen dairy heifers were included in the study.
View Article and Find Full Text PDFBackground: Cachexia is a state of involuntary weight loss common to many chronic diseases. Experimental data, showing that cachexia is related to the enhancement of acute phase response reaction, led to the new definition of cachexia that included, aside from the principal criterion of weight loss, other "minor criteria", Amongst them are levels of C-reactive protein (CRP), albumin and hemoglobin. However, there is paucity of data regarding possible differences of these laboratory parameters in patients with various diseases known to be related to cachexia.
View Article and Find Full Text PDFArch Gynecol Obstet
January 2013
Purpose: Due to increased metabolic requests, pregnancy can be considered as metabolic stress, especially if associated with oxidative stress triggered by disbalance of pro/antioxidants. The aim of the study was to determine serum concentrations of the trace elements iron (Fe), zinc (Zn) and copper (Cu) important in growth regulation and pro/anti-oxidant homeostasis, in relation to the total serum oxidant capacity (TOC) and total serum antioxidant capacity (TAC) in pregnant women with preeclampsia (n = 30) or with gestational hypertension (n = 30) and in healthy pregnant women (n = 37) and non-pregnant women (n = 30) as control groups expecting common differences between all pregnant women and controls and between preeclampsia and the other pregnancies indicating specific disbalance of the oxidative stress and analyzed trace elements.
Methods: Serum Fe was determined by spectrophotometric method, Cu and Zn were determined by atomic absorption spectrometry, TOC was determined by Enzymatic ANTIOX-CAP assay and TAC by Peroxide-activity assay.
Acta Med Croatica
September 2011
Although transplantation of solid organs has become a more standardized method of treatment, liver transplantation represents an exceptional multidisciplinary clinical procedure requiring understanding of specific pathophysiological changes that occur in the end stage of liver disease. Liver transplantation has been performed at Merkur University Hospital since 1998, with 360 transplantations performed to date. The most common indications are alcohol liver disease, cirrhosis caused by hepatitis B and C virus, hepatocellular carcinoma and cryptogenetic liver cirrhosis.
View Article and Find Full Text PDFThe aim of the study was to investigate the effect of infection with Leptospira spp. in horses on activities of platelet-activating factor acetylhydrolase (PAF-AH) and paraoxonase-1 (PON1) considering the anti-inflammatory/anti-oxidative properties of both enzymes. A total of 63 sport and leisure horses' sera were chosen among those routinely serologically examined on leptospirosis during the year 2009 in Croatia.
View Article and Find Full Text PDFSince 2003 when the international norm for implementation of quality management in medical laboratories (EN ISO 15189, Medical laboratories--Particular requirements for quality and competence) was established and accepted, accreditation has become practical, generally accepted method of quality management and confirmation of technical competence of medical laboratories in the whole world. This norm has been translated into Croatian and accepted by the Croatian Institute for Norms as Croatian norm. Accreditation is carried out on voluntary basis by the Croatian Accreditation Agency that has up to now accredited two clinical medical biochemical laboratories in the Republic of Croatia.
View Article and Find Full Text PDFBackground: In accordance with an ongoing activity for worldwide harmonization based on traceability in laboratory methods, the goal of this study was to validate the applicability of recommended "common" reference intervals for serum creatinine concentrations using a specific enzymatic method to the Croatian population.
Methods: The reference group consisted of 240 healthy subjects (120 males and 120 females), between 18 and 74 years of age (median 57 years), who were selected in accordance with the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) recommendations. Creatinine in serum was measured using the creatinine enzymatic assay (Olympus OSR61204) that was standardized to the isotopic dilution mass spectrometry (IDMS) method and National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 967.
Background: C-reactive protein (CRP) as a non-specific inflammatory biomarker has been demonstrated to actively contribute to all stages of atherogenesis. The aim of this study was to investigate the relation between CRP concentrations and the severity of stenosis of cerebral arteries.
Methods: Lipid parameters and CRP levels were measured in the sera of 119 patients with stenosis of the extracranial cerebral arteries established by angiography and compared with the control group, with a normal appearance of the cerebral arteries on ultrasound examination.
Background: Rapid technological progress in point-of-care testing allows the measurement of multiple analytes in whole-blood samples. The present study evaluated biosensor-based methods for the measurement of electrolytes and substrates in whole blood using a Stat Profile Critical Care Xpress (Nova Biomedical, Waltham, MA, USA) multiprofile analyzer and their comparability with standard laboratory methods. Because of the increased utilization of arterial blood samples in hospitalized patients and limited information on differences between arterial and venous blood for most routine laboratory tests, analytical differences caused by different sample types were evaluated.
View Article and Find Full Text PDFAim: To determine the significance of the association between biochemical risk factors for cerebrovascular atherosclerosis (lipid parameters, lipoprotein(a), total homocysteine, total antioxidant status, trace elements, and electrolytes) and the degree of stenosis of cerebral arteries scored by digital subtraction angiography.
Methods: The study included 35 patients with angiographically established < 50% stenosis of cerebral arteries and 55 patients with > or =50% stenosis of cerebral arteries, including obliteration. The control group consisted of 51 patients with normal cerebral arteries on ultrasound examination.
Serum concentration and biological variability (CVB%) of total calcium (Ca) magnesium (Mg), iron (Fe), zinc (Zn) and copper (Cu) were determined in 22 sera of maternal and umbilical cord blood in normal pregnancies. The concentrations of Ca (2.48 +/- 0.
View Article and Find Full Text PDF