Publications by authors named "Per Thayssen"

Aims: The aim of the trial was to examine the influence of ezetimibe on plaque morphology in patients with ST-segment Elevation Myocardial Infarction (STEMI) with respect to fibrous cap thickness (FCT) and arcs of lipid plaque, calcific plaque, and macrophages using Optical Coherence Tomography (OCT).

Methods And Results: In 87 statin naïve patients with STEMI treated with primary percutaneous intervention, a non-culprit study plaque in a non-infarct related coronary artery was assessed with OCT at baseline and after 12 months. Patients were treated with atorvastatin 80 mg and randomized (1:1) to ezetimibe 10 mg (n = 43) or placebo (n = 44).

View Article and Find Full Text PDF

Objectives: This study assessed the incidence and course of healing of uncovered plaque ruptures (PR) following primary percutaneous coronary intervention.

Background: The infarct-related occlusion is frequently located at the lesion site with maximum thrombus burden, whereas the culprit PR may be situated more proximally or distally.

Methods: Uncovered PR in segments adjacent to the stent were identified by optical coherence tomography and intravascular ultrasound using iMap (Boston Scientific, Marlborough, Massachusetts) within 48 h and after 12 months.

View Article and Find Full Text PDF

Introduction: Near-infrared spectroscopy (NIRS) is a new method to identify lipid core plaque (LCP). The LCP and vascular response were assessed with NIRS to examine whether LCP was compressed or redistributed during percutaneous coronary intervention with stent implantation.

Methods: In 25 patients with non-ST segment elevation myocardial infarction (NSTEMI) NIRS acquisition was performed after predilation, stent implantation with nominal pressure and high-pressure post-dilation with a non-compliant balloon.

View Article and Find Full Text PDF

Background: The aim of this study was to examine the influence of ezetimibe in addition to atorvastatin on plaque composition in patients with first-time ST-segment Elevation Myocardial Infarction treated with primary percutaneous intervention.

Methods: Eighty-seven patients were randomized (1:1) to ezetimibe 10mg or placebo in addition to Atorvastatin 80mg. Intravascular ultrasound with iMap was performed at baseline and after 12months in a non-infarct-related artery.

View Article and Find Full Text PDF

Background: Stenting-induced edge dissections (ED) can be assessed in detail by optical coherence tomography (OCT). This study sought to investigate the incidence, morphological characteristics, and spontaneous healing course of OCT-identified EDs following drug-eluting stent (DES) implantation in a non-ST segment elevation myocardial infarction (NSTEMI) patient-population.

Methods: Acute vessel wall injury at the 5-mm stent adjacent distal and proximal reference segments was assessed by post-procedure OCT and intravascular ultrasound (IVUS) in n=97 NSTEMI-patients (n=97 lesions).

View Article and Find Full Text PDF

Background: Coronary drug-eluting stents with biodegradable polymers have been designed to improve safety and efficacy.

Methods And Results: The Scandinavian Organization for Randomized Trials With Clinical Outcome (SORT OUT) VII trial-a large-scale registry-based randomized, multicenter, single-blind, 2-arm, noninferiority trial-compared 2 biodegradable polymer drug-eluting stents: the thin-strut cobalt-chromium sirolimus-eluting Orsiro stent and the stainless steel biolimus-eluting Nobori stent in an all-comer patient population. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 1 year, analyzed by intention to treat (noninferiority margin of 3.

View Article and Find Full Text PDF

Background: Long-term safety and efficacy for everolimus-eluting stents (EES) versus those of sirolimus-eluting stents (SES) are unknown.

Objectives: This study compared 5-year outcomes for EES with those for SES from the SORT OUT IV (Scandinavian Organization for Randomized Trials with Clinical Outcome) trial.

Methods: Five-year follow-up was completed for 2,771 patients (99.

View Article and Find Full Text PDF

Purpose: Frequency-domain optical coherence tomography (FD-OCT) is a high-resolution imaging tool (~10-15 μm), which enables near-histological in-vivo images of the coronary vessel wall. The use of the technique is increasing, both for research- and clinical purposes. This study sought to investigate the intra- and interobserver reliability, as well as the intra-catheter reproducibility of quantitative FD-OCT-assessment of morphometric stent parameters and qualitative FD-OCT-evaluation of strut coverage in 10 randomly selected 6-month follow-up Nobori® biolimus-eluting stents (N-BESs).

View Article and Find Full Text PDF

Background: Third-generation coronary drug-eluting stents (DES) with biodegradable polymers have been designed to improve safety and efficacy. We designed a large scale registry-based randomized clinical trial to compare 2 third-generation DES: a thin strut, cobalt-chromium DES with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the stainless steel biodegradable polymer biolimus-eluting Nobori stents (N-BES, Nobori; Terumo, Tokyo, Japan) in an all-comer patient population.

Design: The multicenter SORT OUT VII trial (NCT01879358) randomly assigned 2,530 patients to treatment with biodegradable polymer O-SES or biodegradable polymer N-BES at 3 sites in Western Denmark.

View Article and Find Full Text PDF

Background: Incomplete strut coverage has been documented an important histopathologic morphometric predictor for later thrombotic events. This study sought to investigate whether optical coherence tomography (OCT)-guided percutaneous coronary intervention with Nobori biolimus-eluting stent implantation in patients with non-ST-segment-elevation myocardial infarction would provide improved strut coverage at 6 months in comparison with angiographic guidance only.

Methods And Results: One hundred patients were randomized 1:1 to either OCT-guided or angio-guided Nobori biolimus-eluting stent implantation.

View Article and Find Full Text PDF

Background: In patients with ST-segment elevation myocardial infarction (STEMI), timely reperfusion with primary percutaneous coronary intervention (PCI) is the preferred treatment. In primary PCI patients with multivessel disease, it is unclear whether culprit vessel PCI only is the preferred treatment. We compared mortality among (1) STEMI patients with single-vessel disease and those with multivessel disease and (2) multivessel disease patients with and without additional revascularization of nonculprit lesions within 2 months after the index PCI.

View Article and Find Full Text PDF

Aims: Reporting of quantitative myocardial blood flow (MBF) is typically performed in standard coronary territories. However, coronary anatomy and myocardial vascular territories vary among individuals, and a coronary artery may erroneously be deemed stenosed or not if territorial demarcation is incorrect. So far, the diagnostic consequences of calculating individually vs.

View Article and Find Full Text PDF

Objective: We aimed to compare angiographic and clinical outcomes after the implantation of everolimus-eluting (EES) and sirolimus-eluting (SES) stents in patients with diabetes.

Background: There are limited data on long-term outcome after EES vs SES implantation in diabetic patients.

Methods: We randomized 213 patients with diabetes and coronary artery disease to EES (n = 108) or SES (n = 105) implantation.

View Article and Find Full Text PDF

Background: New-generation drug-eluting coronary stents have reduced the risk of coronary events, especially in patients with complex disease or lesions. To what extent different stent platforms, polymers, and antiproliferative drugs affect outcomes, however, is unclear. We investigated the safety and efficacy of a third-generation stent by comparing a highly biocompatible durable-polymer-coated zotarolimus-eluting stent with a biodegradable-polymer-coated biolimus-eluting stent.

View Article and Find Full Text PDF

Background: Cardiogenic shock is a serious complication of a ST-segment elevation myocardial infarction (STEMI). We compared short- and long-term mortality among (1) STEMI patients with and without cardiogenic shock and (2) STEMI patients with cardiogenic shock with and without the use of an intra-aortic balloon pump (IABP).

Methods: From January 1, 2002 to December 31, 2010, all patients presenting with STEMI and treated with primary percutaneous coronary intervention (PCI) were identified.

View Article and Find Full Text PDF

We compared 5-year clinical outcomes in diabetic and nondiabetic patients treated with Endeavor zotarolimus-eluting stents (ZESs; Endeavor Sprint, Medtronic, Santa Rosa, California) or Cypher sirolimus-eluting stents (SESs; Cordis, Johnson & Johnson, Warren, New Jersey) coronary implantation. We randomized 2,332 patients to either ZESs (n = 1,162, n = 169 diabetic patients) or SESs (n = 1,170, n = 168 diabetic patients) stratified according to presence or absence of diabetes mellitus. End points included major adverse cardiac event (MACE), a composite of cardiac death, myocardial infarction, target vessel revascularization (TVR), and definite stent thrombosis.

View Article and Find Full Text PDF

Isolated spontaneous coronary intramural hematoma is a unique subset of spontaneous coronary artery dissection that is characterized by a hemorrhage limited to the medial-adventitial layers, causing subsequent hematoma formation without visible intimal flaps. It is an infrequent and serious coronary vessel wall pathology, with poorly understood underlying pathogenic mechanisms. Affected individuals may present with a broad spectrum of symptoms ranging from acute coronary syndromes (ACS) to cardiogenic shock or even sudden cardiac death.

View Article and Find Full Text PDF

Background: The widespread use of coronary stents has exposed a growing population to the risk of stent thrombosis, but the importance in terms of risk of ST-segment elevation myocardial infarctions (STEMIs) remains unclear.

Methods: We studied five years follow-up data for 2,098 all-comer patients treated with coronary stents in the randomized SORT OUT II trial (mean age 63.6 yrs.

View Article and Find Full Text PDF

Background: The impact of adherence to the recommended duration of dual antiplatelet therapy after first generation drug-eluting stent implantation is difficult to assess in real-world settings and limited data are available.

Methods: We followed 4,154 patients treated with coronary drug-eluting stents in Western Denmark for 1 year and obtained data on redeemed clopidogrel prescriptions and major adverse cardiovascular events (MACE, i.e.

View Article and Find Full Text PDF

Objectives: Seven years ago, the DanCell study was carried out to test the hypothesis of improvement in left ventricular ejection fraction (LVEF) following repeated intracoronary injections of autologous bone marrow-derived stem cells (BMSCs) in patients suffering from chronic ischemic heart failure. In this post hoc analysis, the long-term effect of therapy is assessed.

Methods: 32 patients [mean age 61 (SD ± 9), 81% males] with systolic dysfunction (LVEF 33 ± 9%) received two repeated intracoronary infusions (4 months apart) of autologous BMSCs (1,533 ± 765 × 10(6) BMSCs including 23 ± 11 × 10(6) CD34(+) cells and 14 ± 7 × 10(6) CD133(+) cells).

View Article and Find Full Text PDF

Objectives: The study sought to compare the risk of late outcome with a focus on very late definite stent thrombosis of the everolimus-eluting stent (EES) with that of the sirolimus-eluting stent (SES) at 3-year follow-up.

Background: In the SORT OUT IV (SORT OUT IV Trial), comparing the EES with the SES in patients with coronary artery disease, the EES was noninferior to the SES at 9 months. The SORT OUT IV trial provides long-term head-to-head randomized comparison of the EES with the SES.

View Article and Find Full Text PDF

Peri-stent contrast staining and late acquired malapposition represent pathological vessel wall healing patterns following percutaneous coronary intervention with stent implantation. Earlier studies have described these abnormal vessel wall responses commonly present after implantation of first-generation drug-eluting stents. These coronary vascular changes can cause flow disturbance and thereby dispose for later thrombotic events.

View Article and Find Full Text PDF

Background: Contrast-induced nephropathy (CIN) is a serious condition in patients with ST-segment-elevation myocardial infarction treated with primary percutaneous coronary intervention. We compared the risk of acute CIN and the influence of preventive strategies in patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention.

Methods And Results: A total of 720 patients were randomized in the Prevention of Contrast-induced Nephropathy in Patients With ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention (CINSTEMI) trial.

View Article and Find Full Text PDF