To evaluate dual-layer dual-energy computed tomography (dlDECT)-based characterization of thrombus composition for differentiation of acute pulmonary embolism (PE) and chronic thromboembolic pulmonary hypertension (CTEPH). This retrospective single center cohort study included 49 patients with acute PE and 33 patients with CTEPH who underwent CT pulmonary angiography on a dlDECT from 06/2016 to 06/2022. Conventional images), material specific images (virtual non-contrast [VNC], iodine density overlay [IDO], electron density [ED]), and virtual monoenergetic images (VMI) were analyzed.
View Article and Find Full Text PDFObjective: The purpose of this study was to evaluate the effectiveness of a deep learning model (DLM) in improving the sensitivity of neurosurgery residents to detect intracranial aneurysms on CT angiography (CTA) in patients with aneurysmal subarachnoid hemorrhage (aSAH).
Methods: In this diagnostic accuracy study, a set of 104 CTA scans of aSAH patients containing a total of 126 aneurysms were presented to three blinded neurosurgery residents (a first-year, third-year, and fifth-year resident), who individually assessed them for aneurysms. After the initial reading, the residents were given the predictions of a dedicated DLM previously established for automated detection and segmentation of intracranial aneurysms.
Background: In the past decades, cardiovascular magnetic resonance (CMR) was established as a non-invasive tool supporting the diagnosis of myocarditis and there is often reluctance in performing EMB due to potentially severe complications. We sought to identify patient subgroups that could still benefit from EMB in the CMR era.
Methods: Data of patients presenting with myocarditis between 01/2016 and 06/2023 were analysed according to patient risks.
Intrasaccular flow disruption with the Woven Endobridge (WEB) has become a well-established endovascular technique for the treatment of intracranial aneurysms. This study presents our 12-year experience with the WEB and evaluates its evolving indications, procedures, and outcomes. A consecutive series of 324 aneurysms treated with WEB between 2011 and 2023 at three neurovascular centers was retrospectively analyzed and the study group was divided into four treatment periods.
View Article and Find Full Text PDFBackground: The acquisition of contrast-enhanced T1 maps to calculate extracellular volume (ECV) requires contrast agent administration and is time consuming. This study investigates generative adversarial networks for contrast-free, virtual extracellular volume (vECV) by generating virtual contrast-enhanced T1 maps.
Methods And Results: This retrospective study includes 2518 registered native and contrast-enhanced T1 maps from 1000 patients who underwent cardiovascular magnetic resonance at 1.
Purpose: To evaluate a novel flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering (REACT)) for imaging of the extracranial arteries in acute ischemic stroke (AIS) at 1.5 T.
Methods: This retrospective single-center study included 47 AIS patients who received REACT (scan time: 3:01 min) and contrast-enhanced MRA (CE-MRA) of the extracranial arteries at 1.
Background: The continuous technical development of cardiac computed tomography (CT) over the last decades has led to an improvement in image quality and diagnostic accuracy, while simultaneously reducing radiation exposure. Despite these advancements, certain patient-related factors remain a challenge to conduct a high-quality diagnostic examination.
Question: What factors can negatively affect the image quality of cardiac CT and how can these be addressed?
Materials And Methods: Analysis of the available literature on cardiac CT and identification of the quality-limiting factors, discussion, and possible solutions.
Background: Fibromas are rare primary benign cardiac tumours that can become symptomatic due to expansive growth, ventricular rhythm disturbances, and sudden cardiac death. Distinguishing fibromas from other (malign) cardiac masses is essential for accurate diagnosis and treatment. While there is some experience in management of cardiac fibromas in children, management of adult patients is unknown.
View Article and Find Full Text PDFBackground And Purpose: The Pipeline Embolization Device is a safe and effective treatment option for intracranial aneurysms. The newer Pipeline generations have received structural refinements and a surface modification to improve deliverability, procedural safety, and angiographic outcomes. This multicenter study evaluated the clinical safety and efficacy of the 2 surface-modified Pipeline iterations, Pipeline Vantage and Pipeline Flex with Shield Technology (PFS).
View Article and Find Full Text PDFBackground: Diagnosing myocarditis relies on multimodal data, including cardiovascular magnetic resonance (CMR), clinical symptoms, and blood values. The correct interpretation and integration of CMR findings require radiological expertise and knowledge. We aimed to investigate the performance of Generative Pre-trained Transformer 4 (GPT-4), a large language model, for report-based medical decision-making in the context of cardiac MRI for suspected myocarditis.
View Article and Find Full Text PDFObjective: The Pipeline Vantage Embolization Device (PVED) is a novel coated flow diverter with reduced wire diameters to improve neoendothelialization and stent porosity. This systematic review evaluates the safety and efficacy of the PVED based on the current literature.
Methods: Following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines, a thorough literature search was conducted using PubMed, EMBASE, and Cochrane.
Purpose: The WEB 17 system represents the fifth generation of Woven Endobridge (WEB) flow disruptors and features a low profile with fewer wires than its predecessor, the WEB 21. The present study compares the safety and efficacy of the WEB 17 and WEB 21 for the treatment of unruptured cerebral aneurysms with 4-7 mm device sizes, which were available for both systems.
Methods: Patient and aneurysm characteristics, complications, clinical outcome and angiographic results were retrospectively analysed.
Purpose: Multi-sac aneurysms (MSAs) are not uncommon, but studies on their management are scarce. This study aims to evaluate and compare the feasibility, safety, and efficacy of MSAs treated with either clipping or coiling after interdisciplinary case discussion at our center.
Materials And Methods: We retrospectively analyzed MSAs treated by microsurgical clipping, coiling, or stent-assisted coiling (SAC).
Purpose: This study analyzes the long-term clinical and angiographic outcomes of the Derivo Embolization Device (DED), an advanced flow diverter device with an electropolished surface, for the treatment of intracranial aneurysms.
Methods: A consecutive series of 101 patients (mean age: 58 years, 72% female) treated with the DED for 122 aneurysms at a single center between 2017 and 2023 was retrospectively analyzed for major (change in National Institutes of Health Stroke Scale [NIHSS] score ≥ 4 points) and minor (change in NIHSS score < 4 points) neurological events, procedural morbidity (increase of at least one point on the modified Rankin Scale), and angiographic results.
Results: There were 14 (11%) recurrent aneurysms, 15 (12%) ruptured aneurysms, 26 (21%) posterior circulation aneurysms and 16 (13%) fusiform or dissecting aneurysms.
Objective: There are few studies on flow diverters with diameters >5 mm. We present our preliminary experience with the 5.5-8 mm Derivo Embolization Device (DED) implants for the treatment of cerebral aneurysms.
View Article and Find Full Text PDFBackground Errors in radiology reports may occur because of resident-to-attending discrepancies, speech recognition inaccuracies, and large workload. Large language models, such as GPT-4 (ChatGPT; OpenAI), may assist in generating reports. Purpose To assess effectiveness of GPT-4 in identifying common errors in radiology reports, focusing on performance, time, and cost-efficiency.
View Article and Find Full Text PDFBackground: Recently, a disease modifying therapy has become available for transthyretin amyloid cardiomyopathy (ATTR-CM). A validated monitoring concept of treatment is lacking, but a current expert consensus recommends three clinical domains (clinical, biomarker and ECG/imaging) assessed by several measurable features to define disease progression.
Methods: We retrospectively analyzed data of wild-type ATTR-CM patients initiating tafamidis therapy assessed within our local routine protocol at baseline and 6-months follow-up with respect to the frequency of values beyond the proposed thresholds defining disease progression.
Aim: The purpose of this study was to investigate the clinical application of Compressed SENSE accelerated single-breath-hold LGE with 3D isotropic resolution compared to conventional LGE imaging acquired in multiple breath-holds.
Material & Methods: This was a retrospective, single-center study including 105 examinations of 101 patients (48.2 ± 16.
Objective: In preliminary studies, advanced intracranial stents appear to have a favorable safety profile for intracranial aneurysm treatment. This dual-center study is a head-to-head comparison of the low-profile Acandis Acclino stent (a third-generation stent) and the first- and second-generation Enterprise stent.
Methods: Patients who underwent stent-assisted coiling with either the Enterprise or the Acclino stent for unruptured aneurysms during an 8-year period were enrolled and compared for complications, clinical outcomes, and angiographic results.
Objectives: To evaluate dual-layer dual-energy computed tomography (dlDECT)-derived pulmonary perfusion maps for differentiation between acute pulmonary embolism (PE) and chronic thromboembolic pulmonary hypertension (CTEPH).
Methods: This retrospective study included 131 patients (57 patients with acute PE, 52 CTEPH, 22 controls), who underwent CT pulmonary angiography on a dlDECT. Normal and malperfused areas of lung parenchyma were semiautomatically contoured using iodine density overlay (IDO) maps.
Objective: Several studies have demonstrated a high safety and efficacy profile of the Woven EndoBridge (WEB) for endovascular aneurysm treatment. However, contemporary large-scale studies of the WEB are rare. This multicenter study attempts to set a benchmark for state-of-the-art WEB treatment with consistent application of the WEB oversizing technique.
View Article and Find Full Text PDF