Publications by authors named "Pengming Song"

Fourier ptychography (FP) is an enabling imaging technique that produces high-resolution complex-valued images with extended field coverages. However, when FP images a phase object with any specific spatial frequency, the captured images contain only constant values, rendering the recovery of the corresponding linear phase ramp impossible. This challenge is not unique to FP but also affects other common microscopy techniques -- a rather counterintuitive outcome given their widespread use in phase imaging.

View Article and Find Full Text PDF

We present deep-ultraviolet Fourier ptychography (DUV-FP) for high-resolution chemical imaging of biological specimens in their native state without exogenous stains. This approach uses a customized 265-nm DUV LED array for angle-varied illumination, leveraging the unique DUV absorption properties of biomolecules at this wavelength region. We implemented a robust feature-domain optimization framework to overcome common challenges in Fourier ptychographic reconstruction, including vignetting, pupil aberrations, stray light problems, intensity variations, and other systematic errors.

View Article and Find Full Text PDF

Synthetic aperture radar (SAR) utilizes an aircraft-carried antenna to emit electromagnetic pulses and detect the returning echoes. As the aircraft travels across a designated area, it synthesizes a large virtual aperture to improve image resolution. Inspired by SAR, we introduce synthetic aperture ptycho-endoscopy (SAPE) for micro-endoscopic imaging beyond the diffraction limit.

View Article and Find Full Text PDF

Recent advancements in ptychography have demonstrated the potential of coded ptychography (CP) for high-resolution optical imaging in a lensless configuration. However, CP suffers imaging throughput limitations due to scanning inefficiencies. To address this, we propose what we believe is a novel 'fly-scan' scanning strategy utilizing two eccentric rotating mass (ERM) vibration motors for high-throughput coded ptychographic microscopy.

View Article and Find Full Text PDF

Conventional multi-height microscopy techniques introduce different object-to-detector distances to obtain multiple measurements for phase retrieval. However, surpassing the diffraction limit imposed by the numerical aperture (NA) of the objective lens remains a challenging task. Here, we report a novel structured modulation multi-height microscopy technique for quantitative high-resolution imaging.

View Article and Find Full Text PDF

First envisioned for determining crystalline structures, ptychography has become a useful imaging tool for microscopists. However, ptychography remains underused by biomedical researchers due to its limited resolution and throughput in the visible light regime. Recent developments of spatial- and Fourier-domain ptychography have successfully addressed these issues and now offer the potential for high-resolution, high-throughput optical imaging with minimal hardware modifications to existing microscopy setups, often providing an excellent trade-off between resolution and field of view inherent to conventional imaging systems, giving biomedical researchers the best of both worlds.

View Article and Find Full Text PDF

Ptychography is an enabling microscopy technique for both fundamental and applied sciences. In the past decade, it has become an indispensable imaging tool in most X-ray synchrotrons and national laboratories worldwide. However, ptychography's limited resolution and throughput in the visible light regime have prevented its wide adoption in biomedical research.

View Article and Find Full Text PDF

The applications of conventional ptychography are limited by its relatively low resolution and throughput in the visible light regime. The new development of coded ptychography (CP) has addressed these issues and achieved the highest numerical aperture for large-area optical imaging in a lensless configuration. A high-quality reconstruction of CP relies on precise tracking of the coded sensor's positional shifts.

View Article and Find Full Text PDF

Imaging a large number of bio-specimens at high speed is essential for many biomedical applications. The common strategy is to place specimens at different lateral positions and image them sequentially. Here we report a new on-chip imaging strategy, termed depth-multiplexed ptychographic microscopy (DPM), for parallel imaging and sensing at high speed.

View Article and Find Full Text PDF

The recent advent of whole slide imaging (WSI) systems has moved digital pathology closer to diagnostic applications and clinical practices. Integrating WSI with machine learning promises the growth of this field in upcoming years. Here we report the design and implementation of a handheld, colour-multiplexed, and AI-powered ptychographic whole slide scanner for digital pathology applications.

View Article and Find Full Text PDF

The Blu-ray drive is an engineering masterpiece that integrates disc rotation, pickup head translation, and three lasers in a compact and portable format. Here, we integrate a blood-coated image sensor with a modified Blu-ray drive for high-throughput cytometric analysis of various biospecimens. In this device, samples are mounted on the rotating Blu-ray disc and illuminated by the built-in lasers from the pickup head.

View Article and Find Full Text PDF

Multi-height phase retrieval introduces different object-to-detector distances for obtaining phase diversity measurements. In the acquisition process, the slow-varying phase information, however, cannot be converted to intensity variations for detection. Therefore, the low-frequency contents of the phase profile are lost during acquisition and cannot be properly restored via phase retrieval.

View Article and Find Full Text PDF

Whole slide imaging (WSI) has moved the traditional manual slide inspection process to the era of digital pathology. A typical WSI system translates the sample to different positions and captures images using a high numerical aperture (NA) objective lens. Performing oil-immersion microscopy is a major obstacle for WSI as it requires careful liquid handling during the scanning process.

View Article and Find Full Text PDF

Ptychography-based lensless on-chip microscopy enables high-throughput imaging by retrieving the missing phase information from intensity measurements. Numerous reconstruction algorithms for ptychography have been proposed, yet only a few incremental algorithms can be extended to lensless on-chip microscopy because of large-scale datasets but limited computational efficiency. In this paper, we propose the use of accelerated proximal gradient methods for blind ptychographic phase retrieval in lensless on-chip microscopy.

View Article and Find Full Text PDF

We report the implementation of a fully on-chip, lensless microscopy technique termed optofluidic ptychography. This imaging modality complements the miniaturization provided by microfluidics and allows the integration of ptychographic microscopy into various lab-on-a-chip devices. In our prototype, we place a microfluidic channel on the top surface of a coverslip and coat the bottom surface with a scattering layer.

View Article and Find Full Text PDF

Traditional microbial detection methods often rely on the overall property of microbial cultures and cannot resolve individual growth event at high spatiotemporal resolution. As a result, they require bacteria to grow to confluence and then interpret the results. Here, we demonstrate the application of an integrated ptychographic sensor for lensless cytometric analysis of microbial cultures over a large scale and with high spatiotemporal resolution.

View Article and Find Full Text PDF

We report a new, to the best of our knowledge, lensless microscopy configuration by integrating the concepts of transverse translational ptychography and defocus multi-height phase retrieval. In this approach, we place a tilted image sensor under the specimen for introducing linearly increasing phase modulation along one lateral direction. Similar to the operation of ptychography, we laterally translate the specimen and acquire the diffraction images for reconstruction.

View Article and Find Full Text PDF

Whole slide imaging (WSI) systems convert the conventional biological samples into digital images. Existing commercial WSI systems usually require an expensive high-performance motorized stage to implement the precise mechanical control, and the cost is prohibitive for most individual pathologists. In this work, we report a low-cost WSI system using the off-the-shelf components, including a computer numerical control (CNC) router, a photographic lens, a programmable LED array, a fluorescence filter cube, and a surface-mount LED.

View Article and Find Full Text PDF
Article Synopsis
  • Fourier ptychography (FP) is a computational imaging technique for high-resolution images, but it struggles with optical aberration, which affects image quality.
  • The authors developed a neural network model to accurately estimate aberrations and produce artifact-free reconstructions, utilizing TensorFlow for optimization.
  • Tests showed this method offers improved robustness against optical distortions and enhances image clarity by minimizing artifacts, paving the way for better imaging solutions through a neural network approach.
View Article and Find Full Text PDF

Fourier ptychographic microscopy (FPM) is a computational approach geared towards creating high-resolution and large field-of-view images without mechanical scanning. Acquiring color images of histology slides often requires sequential acquisitions with red, green, and blue illuminations. The color reconstructions often suffer from coherent artifacts that are not presented in regular incoherent microscopy images.

View Article and Find Full Text PDF

Whole slide imaging (WSI) has moved digital pathology closer to diagnostic practice in recent years. Due to the inherent tissue topography variability, accurate autofocusing remains a critical challenge for WSI and automated microscopy systems. The traditional focus map surveying method is limited in its ability to acquire a high degree of focus points while still maintaining high throughput.

View Article and Find Full Text PDF

We report an angle-tilted, wavelength-multiplexed ptychographic modulation approach for multispectral lensless on-chip microscopy. In this approach, we illuminate the specimen with lights at five wavelengths simultaneously. A prism is added at the illumination path for spectral dispersion.

View Article and Find Full Text PDF

We report a novel lensless on-chip microscopy platform based on near-field blind ptychographic modulation. In this platform, we place a thin diffuser in between the object and the image sensor for light wave modulation. By blindly scanning the unknown diffuser to different x-y positions, we acquire a sequence of modulated intensity images for quantitative object recovery.

View Article and Find Full Text PDF

We report a new coherent imaging technique, termed ptychographic structured modulation (PSM), for quantitative super-resolution microscopy. In this technique, we place a thin diffuser (i.e.

View Article and Find Full Text PDF

Background: Digital pathology is experiencing an exponential period of growth catalyzed by advancements in imaging hardware and progresses in machine learning. The use of whole slide imaging (WSI) for digital pathology has recently been cleared for primary diagnosis in the US. The demand for using frozen section procedure for rapid identification of cancerous tissue during surgery is another driving force for the development of WSI.

View Article and Find Full Text PDF