Publications by authors named "Pedro D Wendel Garcia"

Background: Bacterial pulmonary superinfections develop in a substantial proportion of mechanically ventilated COVID-19 patients and are associated with prolonged mechanical ventilation requirements and increased mortality. Albeit recommended, evidence supporting the use of empirical antibiotics at intubation is weak and of low quality. The aim of this study was to elucidate the effect of empirical antibiotics, administered within 24 h of endotracheal intubation, on superinfections, duration of mechanical ventilation, and mortality in mechanically ventilated patients with COVID-19.

View Article and Find Full Text PDF

Purpose: Hyperoxemia is common in patients resuscitated after out-of-hospital cardiac arrest (OHCA) admitted to the intensive care unit (ICU) and may increase the risk of mortality. However, the effect of hyperoxemia on functional outcome, specifically related to the timing of exposure to hyperoxemia, remains unclear.

Methods: The secondary analysis of the Target Temperature Management 2 (TTM-2) randomized trial.

View Article and Find Full Text PDF

Background: Cuffed endotracheal tubes (cETT) pose the potential advantage of an infrequent need for reintubation in pediatric patients compared to uncuffed tubes. The aim of this study was to investigate tube exchange rates using second generation Microcuff® pediatric endotracheal tubes (PET) with an adapted sizing recommendation in a large single institution cohort of children and to identify potential variables associated with an elevated risk of tube exchange.

Methods: Patient data obtained from the electronic patient data management system of the Department of Anesthesia, University Children's Hospital Zurich, Switzerland, were retrospectively assessed for demographic and anthropometric information, size of the internal tube diameter used for positive pressure ventilation and divergence from the size recommendation chart.

View Article and Find Full Text PDF

Background: The handover and associated shift start checks by nurses of critical care patients are complex and prone to errors. However, which aspects lead to errors remains unknown. Fewer errors might occur in a structured approach.

View Article and Find Full Text PDF

Background: Prehospital point-of-care ultrasound allows an unstable patient to be rapidly and accurately assessed. However, we are concerned that an excessive focus on the ultrasound device, in an already demanding emergency medical service environment, may distract from patient care, potentially leading to reduced situational awareness and the neglect of other crucial instruments, such as the patient monitor. Thus, in this study, we examined the influence of prehospital ultrasound on situational awareness, by studying the degree to which physicians were distracted from the patient monitor.

View Article and Find Full Text PDF

Background: Connecting an infusion line to a closed stopcock results in pressurization of fluid within the syringe infusion pump assembly leading to flow irregularities when opening the stopcock and activating the pump.

Aims: It was the purpose of this study to assess the extent of pressurization under different conditions and its impact on start-up fluid delivery.

Methods: Intraluminal pressures and start-up fluid delivery at 1 mL/h flow rate were assessed with connection of the infusion line 1 min (delayed connection) or immediately after purging (immediate connection) using two different infusion lines made from polyvinylchloride (PVC) or polyethylene (PE).

View Article and Find Full Text PDF

Background: Coagulopathy is part of the pathological host response to infection in sepsis. Higher plasma concentrations of both tissue factor (TF) and tissue factor pathway inhibitor (TFPI) are associated with occurrence of disseminated intravascular coagulation (DIC), multi-organ dysfunction and increased mortality in patients with sepsis. Currently no treatment approaches specifically targeting this axis are available.

View Article and Find Full Text PDF

Covalent Organic Frameworks (COFs) emerged as versatile materials with promising potential in  biomedicine. Their customizable functionalities and tunable pore structures make them valuable for various biomedical applications such as biosensing, bioimaging, antimicrobial activity, and targeted drug delivery. Despite efforts made to create nanoscale COFs (nCOFs) to enhance their interaction with biological systems, a comprehensive understanding of their inherent biological activities remains a significant challenge.

View Article and Find Full Text PDF
Article Synopsis
  • Airway management is vital in treating out-of-hospital cardiac arrest (OHCA), focusing on whether tracheal intubation (TI) or supraglottic airway devices (SGA) lead to better patient outcomes.
  • A secondary analysis of the TTM2 trial included 1702 adult OHCA patients and found that most (71.6%) received TI, while 28.4% were managed with SGA.
  • Results indicated that the type of airway management did not significantly affect outcomes like ventilator-free days, neurological status, or mortality rates after 26 days.
View Article and Find Full Text PDF
Article Synopsis
  • Circulatory shock and multi-organ failure happen when the body doesn't get enough oxygen, making patients really sick.
  • The study looked at how well the tiny blood vessels (capillaries) can work in patients with and without circulatory shock by checking their blood flow after giving them nitroglycerin.
  • Results showed that patients with circulatory shock had lower blood flow in their capillaries, even after treatment, but some other heart measures were higher compared to those who weren't in shock.
View Article and Find Full Text PDF

Introduction: Mechanical power of ventilation, a summary parameter reflecting the energy transferred from the ventilator to the respiratory system, has associations with outcomes. INTELLiVENT-Adaptive Support Ventilation is an automated ventilation mode that changes ventilator settings according to algorithms that target a low work-and force of breathing. The study aims to compare mechanical power between automated ventilation by means of INTELLiVENT-Adaptive Support Ventilation and conventional ventilation in critically ill patients.

View Article and Find Full Text PDF

Objectives: Simulating a realistic "cannot intubate, cannot oxygenate" (CICO) situation to train an "emergency front of neck airway" is difficult. It further remains unclear if provision of regular technical refreshers improves performance in the setting of a real CICO situation. The purpose of this prospective study on an established surgical rabbit cadaver tracheostomy model was to evaluate the benefit of viewing training material shortly before performing "emergency front of neck airway.

View Article and Find Full Text PDF

Objectives: To assess the risk of venous thromboembolic events (VTEs) and bleeding with or without thromboprophylaxis during neoadjuvant chemotherapy in bladder cancer patients scheduled for radical cystectomy.

Materials And Methods: We conducted a retrospective cohort study in 4886 patients with non-metastatic bladder cancer undergoing cystectomy across 28 centres in 13 countries between 1990 and 2021. Inverse probability weighting analyses were performed to estimate the effect of thromboprophylaxis on VTE and bleeding.

View Article and Find Full Text PDF

Background: Norepinephrine (NE) is a cornerstone drug in the management of septic shock, with its dose being used clinically as a marker of disease severity and as mortality predictor. However, variations in NE dose reporting either as salt formulations or base molecule may lead to misinterpretation of mortality risks and hinder the process of care.

Methods: We conducted a retrospective analysis of the MIMIC-IV database to assess the impact of NE dose reporting heterogeneity on mortality prediction in a cohort of septic shock patients.

View Article and Find Full Text PDF

During the COVID-19 pandemic, there was a notable undersupply of respiratory support devices, especially in low- and middle-income countries. As a result, many hospitals turned to alternative respiratory therapies, including the use of gas-operated ventilators (GOV). The aim of this study was to describe the use of GOV as a noninvasive bridging respiratory therapy in critically ill COVID-19 patients and to compare clinical outcomes achieved with this device to conventional respiratory therapies.

View Article and Find Full Text PDF

Background: There is limited knowledge about gaze patterns of intensive care unit (ICU) trainee doctors during the insertion of a central venous catheter (CVC). The primary objective of this study was to examine visual patterns exhibited by ICU trainee doctors during CVC insertion. Additionally, the study investigated whether differences in gaze patterns could be identified between more and less experienced trainee doctors.

View Article and Find Full Text PDF

Background: The continuous exposure of blood to a non-biological surface during extracorporeal membrane oxygenation (ECMO) may lead to progressive thrombus formation in the oxygenator, hemolysis and consequently impaired gas exchange. In most centers oxygenator performance is monitored only on a once daily basis. Carboxyhemoglobin (COHb) is generated upon red cell lysis and is routinely measured with any co-oximetry performed to surveille gas exchange and acid-base homeostasis every couple of hours.

View Article and Find Full Text PDF

The purpose of this in vitro study was to evaluate the impact of the vertical level of the stopcock connecting the infusion line to the central venous catheter on start-up fluid delivery in microinfusions. Start-up fluid delivery was measured under standardized conditions with the syringe outlet and liquid flow sensors positioned at heart level (0 cm) and exposed to a simulated CVP of 10 mmHg at a set flow rate of 1 ml/h. Flow and intraluminal pressures were measured with the infusion line connected to the stopcock primarily placed at vertical levels of 0 cm, + 30 cm and - 30 cm or primarily placed at 0 cm and secondarily, after connecting the infusion line, displaced to + 30 cm and - 30 cm.

View Article and Find Full Text PDF