Publications by authors named "Paweena U-Thainual"

Purpose: The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner.

View Article and Find Full Text PDF

Objective: Perineural ganglion impar injections are used in the management of pelvic pain syndromes; however, there is no consensus regarding the optimal image guidance. Magnetic resonance imaging (MRI) provides high soft tissue contrast and the potential to directly visualize and target the ganglion. The purpose of this study was to assess the feasibility of MR-guided percutaneous perineural ganglion impar injections.

View Article and Find Full Text PDF

Optical-resolution photoacoustic microscopy (ORPAM) in theory provides lateral resolution equivalent to the optical diffraction limit. Scattering media, such as biological turbid media, attenuates the optical signal and also alters the diffraction-limited spot size of the focused beam. The ORPAM signal is generated only from a small voxel in scattering media with dimensions equivalent to the laser spot size after passing through scattering layers and is detected by an acoustic transducer, which is not affected by optical scattering.

View Article and Find Full Text PDF

The radiant exposure of optical irradiation beams with different scanning parameters has been theoretically studied. We analyzed the difference in radiant exposure introduced by Gaussian and top hat beams. Various parameters such as scanning pattern, aperture position, beam size and scan spacing were also introduced in this study.

View Article and Find Full Text PDF

We propose a quantification method called Mapped Average Principal component analysis Score (MAPS) to enumerate the contamination coverage on common medical device surfaces. The method was adapted from conventional Principal Component Analysis (PCA) on non-overlapped regions of a full frame hyperspectral image to resolve the percentage of contamination from the substrate. The concept was proven by using a controlled contamination sample with artificial test soil and color simulating organic mixture, and was further validated using a bacterial system including biofilm on stainless steel surface.

View Article and Find Full Text PDF

Purpose: To evaluate the feasibility of magnetic resonance imaging (MRI)-guided vertebroplasty at 1.5 Tesla using augmented reality image overlay navigation.

Materials And Methods: Twenty-five unilateral vertebroplasties [5 of 25 (20%) thoracic, 20 of 25 (80%) lumbar] were prospectively planned in 5 human cadavers.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to prospectively test the hypothesis that image overlay technology facilitates accurate navigation for magnetic resonance (MR)-guided osseous biopsy.

Materials And Methods: A prototype augmented reality image overlay system was used in conjunction with a clinical 1.5-T MR imaging system.

View Article and Find Full Text PDF

Purpose: A clinical augmented reality guidance system was developed for MRI-guided musculoskeletal interventions Magnetic Resonance Image Overlay System (MR-IOS). The purpose of this study was to assess MRI compatibility, system accuracy, technical efficacy, and operator performance of the MR-IOS.

Methods And Materials: The impact of the MR-IOS on the MR environment was assessed by measuring image quality with signal-to-noise ratio (SNR) and signal intensity uniformity with the system in various on/off states.

View Article and Find Full Text PDF

Purpose: To prospectively assess overlay technology in providing accurate and efficient targeting for magnetic resonance (MR) imaging-guided shoulder and hip joint arthrography.

Materials And Methods: A prototype augmented reality image overlay system was used in conjunction with a clinical 1.5-T MR imager.

View Article and Find Full Text PDF

Objectives: To prospectively assess the technical performance of an augmented reality system for MR-guided spinal injection procedures.

Methods: The augmented reality system was used with a clinical 1.5-T MRI system.

View Article and Find Full Text PDF

Objective: The purpose of this study was to prospectively evaluate the accuracy of an augmented reality image overlay system in MRI-guided spinal injection procedures.

Materials And Methods: An augmented reality prototype was used in conjunction with a 1.5-T MRI system.

View Article and Find Full Text PDF

The purpose of this study was to determine if augmented reality image overlay and laser guidance systems can assist medical trainees in learning the correct placement of a needle for percutaneous facet joint injection. The Perk Station training suite was used to conduct and record the needle insertion procedures. A total of 40 volunteers were randomized into two groups of 20.

View Article and Find Full Text PDF

Motivation: Image-guided percutaneous (through the skin) needle-based surgery has become part of routine clinical practice in performing procedures such as biopsies, injections and therapeutic implants. A novice physician typically performs needle interventions under the supervision of a senior physician; a slow and inherently subjective training process that lacks objective, quantitative assessment of the surgical skill and performance. Shortening the learning curve and increasing procedural consistency are important factors in assuring high-quality medical care.

View Article and Find Full Text PDF