There is limited knowledge of pulmonary physiology and pulmonary function after continuous flow-left ventricular assist device (CF-LVAD) implantation. Therefore, this study investigated whether CF-LVAD influenced pulmonary circulation by assessing pulmonary capillary blood volume and alveolar-capillary conductance in addition to pulmonary function in patients with heart failure. Seventeen patients with severe heart failure who were scheduled for CF-LVAD implantation (HeartMate II, III, Abbott, Abbott Park, IL or Heart Ware, Medtronic, Minneapolis, MN) participated in the study.
View Article and Find Full Text PDFCzech physiologist Penaz tried to overcome limitations of invasive pulse-contour methods (PCM) in clinical applications by a non-invasive method (finger mounted BP cuff) for continuous arterial waveform detection and beat-to-beat analysis. This discovery resulted in significant interest in human physiology and non-invasive examination of hemodynamic parameters, however has limitations because of the distal BP recording using a volume-clamp method. Thus, we propose a validation of beat-to-beat signal analysis acquired by novel a brachial occlusion-cuff (suprasystolic) principle and signal obtained from Finapres during a forced expiratory effort against an obstructed airway (Valsalva maneuver).
View Article and Find Full Text PDFBackground: Methacholine bronchoprovocation or challenge testing (MCT) is commonly performed to assess airway hyper-responsiveness in the setting of suspected asthma. Nebulization is an aerosol-generating procedure, but little is known about the risks of MCT in the context of the ongoing coronavirus disease 2019 (COVID-19) pandemic. We aimed to quantify and characterize aerosol generation during MCT by using different delivery methods and to assess the impact of adding a viral filter.
View Article and Find Full Text PDFThree and five-layered silicon carbide-based composites containing 0, 5, and 15 wt.% of graphene nanoplatelets (GNPs) were prepared with the aim to obtain a sufficiently high electrical conductivity in the surface layer suitable for electric discharge machining (EDM). The layer sequence in the asymmetric three-layered composites was SiC/SiC-5GNPs/SiC-15GNPs, while in the symmetric five-layered composite, the order of layers was SiC-15GNPs/SiC-5GNPs/SiC/SiC-5GNPs/SiC-15GNPs.
View Article and Find Full Text PDFBackground: Peak flow testing is a common procedure performed in ambulatory care. There are currently no data regarding aerosol generation during this procedure. Given the ongoing debate regarding the potential for aerosol transmission of SARS-CoV-2, we aimed to quantify and characterize aerosol generation during peak flow testing.
View Article and Find Full Text PDFBackground: Characterization of aerosol generation during exercise can inform the development of safety recommendations in the face of COVID-19.
Research Question: Does exercise at various intensities produce aerosols in significant quantities?
Study Design And Methods: In this experimental study, subjects were eight healthy volunteers (six men, two women) who were 20 to 63 years old. The 20-minute test protocol of 5 minutes rest, four 3-minute stages of exercise at 25%, 50%, 75%, and 100% of age-predicted heart rate reserve, and 3 minutes active recovery was performed in a clean, controlled environment.
Background: The role of portable high-efficiency particulate air (HEPA) filters for supplemental aerosol mitigation during exercise testing is unknown and might be relevant during COVID-19 pandemic.
Research Question: What is the effect of portable HEPA filtering on aerosol concentration during exercise testing and its efficiency in reducing room clearance time in a clinical exercise testing laboratory?
Study Design And Methods: Subjects were six healthy volunteers aged 20 to 56 years. In the first experiment, exercise was performed in a small tent with controlled airflow with the use of a stationary cycle, portable HEPA filter with fume hood, and particle counter to document aerosol concentration.
Sarcopenia, a syndrome commonly seen in elderly populations, is often characterized by a gradual loss of skeletal muscle, leading to the decline of muscle strength and physical performance. Growing evidence suggests that the prevalence of sarcopenia increases in patients with heart failure (HF), which is a dominant pathogenesis in the aging heart. HF causes diverse metabolic complications that may result in sarcopenia.
View Article and Find Full Text PDFBackground: Noninvasive outpatient monitoring for heart failure (HF) has significant opportunity to reduce patient morbidity and the costs associated with recurrent hospitalization. The purpose of this study was to validate the ability of radiofrequency (RF) to assess lung fluid via a wearable patch device compared to thoracic CT in order to characterize volume overload.
Methods: 120 subjects were studied: 66 acute heart failure (AHF) inpatients and 54 subjects without AHF (Control - 44 healthy and 10 stable HF).
HeartMate II left ventricular assist device controllers provide data including pulsatility index, reflecting the relationship between pump function and hemodynamics. We propose that a higher pulsatility index at hospital discharge following implant may be associated with less vascular congestion and improved clinical outcomes. A retrospective analysis of 40 patients (age 59.
View Article and Find Full Text PDFArterial oxygen tension and oxyhemoglobin saturation () decrease in parallel during hypoxia. Distinguishing between changes in oxygen tension and oxygen content as the relevant physiological stimulus for cardiorespiratory alterations remains challenging. To overcome this, we recruited nine individuals with hemoglobinopathy manifesting as high-affinity hemoglobin [HAH; partial pressure at 50% (P) = 16 ± 0.
View Article and Find Full Text PDFIntroduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the 'cuff pulsatility index'.
View Article and Find Full Text PDFCardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle.
View Article and Find Full Text PDFUnlabelled: This study investigated whether rIPC alters the typical changes in pulmonary arterial pressure, pulmonary gas exchange associated with exercise in hypoxia.
Methods: 16 healthy adults were randomized to either rIPC treatment (n = 8) or control (n = 8). Afterward, subjects performed supine ergometry at constant load (30 W, 40˜50 rpm) for 25 min during hypoxia (12.
Aim: The lungs-and particularly the alveolar-capillary membrane-may be sensitive to continuous flow (CF) and pulmonary pressure alterations in heart failure (HF). We aimed to investigate long-term effects of CF pumps on respiratory function.
Methods And Results: We conducted a retrospective study of patients with end-stage HF at our institution.
The gold standard for noninvasive blood pressure (BP) measurement, the Doppler technique, does not provide systolic blood pressure (SBP) and diastolic blood pressure (DBP) and may limit therapy outcomes. To improve patient care, we tested specifically designed experimental BP (ExpBP) monitor and the Doppler technique by comparing noninvasive measures to the intraarterial (I-A) BP in 31 patients with end-stage heart failure (4 females) 2.6 ± 3.
View Article and Find Full Text PDFCardiac output (CO) assessment as a basic hemodynamic parameter has been of interest in exercise physiology, cardiology, and anesthesiology. Noninvasive techniques available are technically challenging, and thus difficult to use outside of a clinical or laboratory setting. We propose a novel method of noninvasive CO assessment using a single, upper-arm cuff.
View Article and Find Full Text PDFCongestive heart failure (HF) remains a serious burden in the Western World. Despite advances in pharmacotherapy and resynchronization, many patients have progression to end-stage HF. These patients may be candidates for heart transplant or left ventricular assist device (LVAD) therapy.
View Article and Find Full Text PDFNeurohormonal blockade drug therapy (NHBDT) is the cornerstone therapy in heart failure (HF) management for promoting reverse cardiac remodeling and improving outcomes. It's utility in left ventricular assist device (LVAD) supported patients remains undefined. Sixty-four patients who received continuous flow LVAD at our institution were retrospectively reviewed and divided into 2 groups: no-NHBDT group (n = 33) received LVAD support only and NHBDT group (n = 31) received concurrent NHBDT based on the clinical judgment of the attending physicians.
View Article and Find Full Text PDFSystemic arterial blood pressure (BP) is one of the most important parameters of the cardiovascular system. An oscillometric NIBP monitor was specifically designed to measure oscillometric pulsations and mean arterial pressure (MAP) during inflation and deflation of the cuff. Nineteen healthy young (age 23.
View Article and Find Full Text PDF