Publications by authors named "Paulo Simamoto Junior"

Background: Obstructive sleep apnea (OSA) is a very common condition in patients with temporomandibular disorders (TMD). However, there is little evidence of a connection between them.

Objective: The aim of this systematic review and meta-analysis is to assess the association between OSA and TMD in adult population.

View Article and Find Full Text PDF

The objective of this study is to examine the mechanical behavior of two-piece abutments (Morse taper with 16° internal angulation and Morse taper with 11.5° internal angulation) before and after cyclic fatigue testing, following ISO 14801:2016 guidelines. The specimens were divided into three groups: a modified Morse taper with a taper angle of 16° (GM group), a conventional Morse taper (taper angle of 11.

View Article and Find Full Text PDF

Objective: To evaluate the chemical and mechanical properties of enamel submitted to different in vitro radiation protocols.

Design: Third molars were divided into seven groups (n = 8): non-irradiated (NI); a single dose of 30 Gy (SD30), 50 Gy (SD50), or 70 Gy (SD70) of radiation; or fractional radiation doses of up to 30 Gy (FD30), 50 Gy (FD50), or 70 Gy (FD70). Hemisections were analysed by Fourier transform infrared spectroscopy (FTIR), energy dispersive X-ray spectroscopy (EDS) and Knoop microhardness (KHN) test.

View Article and Find Full Text PDF

With the onset of the new coronavirus disease (COVID-19) pandemic, the dental treatment of patients at risk of infection has become quite challenging. In view of this, patients with head and neck cancer may present with oral complications due to anticancer therapy, making dental assistance necessary. Thus, the objective of the study was to review the literature and critically discuss important concerns about the treatment of patients with head and neck cancer during the COVID-19 pandemic.

View Article and Find Full Text PDF

Objective: The aim of this study was to evaluate the mandibular and articular dynamics and the presence of complications associated with surgical or nonsurgical treatments of condylar fractures.

Study Design: Clinical trials that compared open reduction internal fixation and maxillomandibular fixation in patients with condylar fractures were included. We performed an electronic search of PubMed, Scopus, Cochrane Library, Web of Science, and LILACS (Latin American and Caribbean Health Sciences) databases starting from February 2017 and updated in January 2019 and found 467 articles.

View Article and Find Full Text PDF

Purpose: To assess studies on edentulous patients rehabilitated using mandibular implant-supported profile prostheses and analyze the impact of different numbers of implants used on the implant survival rate, peri-implant bone loss, and prosthesis survival rate.

Materials And Methods: This systematic review adhered to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) statement and was registered on PROSPERO. The PubMed/MEDLINE database was searched for articles published before July 18, 2016.

View Article and Find Full Text PDF

Introduction: Congenital intraoral synechias are adhesions of intraoral structures involving soft tissue. These conditions and another anomaly called ankyloblepharon filiforme adnatum, which is partial fusion of the eyelid margins by bands of tissue, are rarely reported in the literature. The association of both anomalies of the craniomaxillofacial region is an even more unusual finding.

View Article and Find Full Text PDF

Purpose: To evaluate the influence of different implant numbers and connection types on the biomechanical behavior of mandibular full-arch implant-supported rehabilitation.

Materials And Methods: Computed tomography-based finite element models comprising a totally edentulous mandible and 3.8 × 13-mmdiameter implants, abutments, abutment screws, bar retaining screw, and bar were constructed.

View Article and Find Full Text PDF

The aim of this study was to evaluate the flexural strength and flexural modulus of different fiber-reinforcement composite (FRC) posts and determine the correlation between mechanical properties and structural characteristics. Eleven brands of fiber posts were analyzed (n=10): Exacto Cônico (Angelus), DT Light SL (VDW), RelyX Fiber Post (3M-Espe), Glassix Radiopaque (Nordim), Para Post Fiber White (Coltène), FRC Postec Plus (Ivoclar), Aestheti-Plus Post (Bisco), Superpost Cônico Estriado (Superdont), Superpost Ultrafine (Superdont), Reforpost (Angelus), and White Post DC (FGM). The posts were loaded in three-point bending test to calculate the flexural strength and flexural modulus using a mechanical testing machine (EMIC 2000 DL) at 0.

View Article and Find Full Text PDF

The aim of this study was to verify the degree of conversion (DC), Vickers microhardness (VH) and elastic modulus (E) of resin cements cured through different ceramic systems. One 1.5-mm-thick disc of each ceramic system (feldspathic, lithium dissilicate and zircônia veneered with feldspathic) was used.

View Article and Find Full Text PDF

Statement Of Problem: Framework longevity is a key factor for the success of complete-arch prostheses and commonly depends on the welding methods. However, no consensus has been reached on the joint design and welding type for improving framework resistance.

Purpose: The purpose of this study was to assess the effect of different joint designs and welding methods with tungsten inert gas (TIG) or laser to join titanium alloy bars (Ti-6Al-4V).

View Article and Find Full Text PDF

Statement Of Problem: The literature provides limited information regarding the performance of Ti-6Al-4V laser and plasma joints welded in prefabricated bars in dental applications.

Purpose: The purpose of this study was to evaluate the mechanical strength of different diameters of Ti-6Al-4V alloy welded with laser and plasma techniques.

Material And Methods: Forty-five dumbbell-shaped rods were created from Ti-6Al-4V and divided into 9 groups (n=5): a control group with 3-mm and intact bars; groups PL2.

View Article and Find Full Text PDF

Purpose: To observe the photoelastic stress patterns generated around implants in relation to variations in the diameter and total number of implants supporting fixed complete-arch mandibular frameworks.

Materials And Methods: Three different implant configurations were analyzed (n = 3): 5 standard implants with diameters of 3.75 mm (C), 3 standard implants with diameters of 3.

View Article and Find Full Text PDF

The aim of this prospective clinical study was to evaluate patient rehabilitation with two immediately loaded implants and bar-retained mandibular overdentures after 48 months of follow-up. Twenty patients were treated with two implants each; of these, 17 patients were re-evaluated for comparison. Gender, age, plaque index, gingival inflammation, keratinized mucosa, probing depth, bleeding, and implant loss data were recorded, and periapical radiographs were obtained for measurement of marginal bone loss.

View Article and Find Full Text PDF

In the event of the loss of an implant and to take advantage of the preexisting structures, a rescue procedure that allows continuous use of the original fixed restoration during the restoration of the tripod support at the implant level can be used. When nonphysiological occlusion forces are avoided, the success rate of this rescue procedure is very similar to any other rehabilitation made following a conventional protocol. Furthermore, the fact that the patient has already adapted to the prosthesis position and its vertical dimension results in easier functional adaptation in the postoperative period and, consequently, greater comfort.

View Article and Find Full Text PDF

Statement Of Problem: It is unclear how the amount of remaining coronal dentin and the type of post and core rehabilitation affect the strain, stress distribution, and fracture resistance of endodontically treated teeth.

Purpose: The purpose of this study was to evaluate the effects of the type of post, type of crown, and the amount of remaining coronal dentin on the biomechanical behavior of endodontically treated teeth.

Material And Methods: The investigation was conducted by using 3-dimensional finite element analysis and laboratory tests.

View Article and Find Full Text PDF

The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10).

View Article and Find Full Text PDF

Statement Of Problem: Unresolved controversy exists concerning the best technique for restoring endodontically treated teeth. Prefabricated posts have been recommended with some debate as a method of restoring pulpless teeth before placement of the final restoration.

Purpose: The purpose of this in vitro study was to evaluate the effect on the strain, fracture resistance, and fracture mode of endodontically treated human incisors of 4 types of restorations with or without glass fiber posts after thermal cycling.

View Article and Find Full Text PDF

Restoring flared endodontically treated teeth continues to be a challenge for clinicians. This study evaluated the effect of post types and restorative techniques on the strain, fracture resistance, and fracture mode of incisors with weakened roots. One hundred five endodontically treated bovine incisors roots (15 mm) were divided into 7 groups (n=15).

View Article and Find Full Text PDF

The loss of gingival volume is a major challenge for dental surgeons with implant-supported fixed prosthesis manufactures, particularly from an aesthetics perspective in patients with a high smile line. Gingival tissue remodeling can help in papillae formation to avoid soft tissue surgery by reestablishing the appropriate shape and gingival contour of the tissues. This improves not only the aesthetics, but also the phonetics of the patient.

View Article and Find Full Text PDF

This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3).

View Article and Find Full Text PDF

Purpose: To investigate the peri-implant stress fields generated from four different implant-abutment interfaces under axial loading applied at the center of the implant and several millimeters away from the implant center via photoelastic analysis.

Materials And Methods: Similar unthreaded and cylindric implants and abutments were fabricated and embedded in photoelastic resin with four different implant-abutment interfaces: external hex, internal hex, internal taper (11.5 degrees), and solid connection to the abutment (one piece).

View Article and Find Full Text PDF

Purpose: The aim of the present study was to evaluate the influence of abutment screw tightening force before laser welding procedures on the vertical fit of metal frameworks over four implants.

Materials And Methods: To construct the frameworks, prefabricated titanium abutments and cylindrical titanium bars were joined by laser welding to compose three groups: group of manual torque (GMT), GT10 and GT20. Before welding, manual torque simulating routine laboratory procedure was applied to GTM.

View Article and Find Full Text PDF