J Chromatogr A
August 2024
This study addresses the analysis of emerging contaminants, often using chromatographic techniques coupled to mass spectrometry. However, sample preparation is often required prior to instrumental analysis, and dispersive liquid-liquid microextraction (DLLME) is a viable strategy in this context. DLLME stands out for its ability to reduce sample and solvent volumes.
View Article and Find Full Text PDFOmics analyses collectively refer to the possibility of profiling genetic variants, RNA, epigenetic markers, proteins, lipids, and metabolites. The most common analytical approaches used for detecting molecules present within biofluids related to metabolism are vibrational spectroscopy techniques, represented by infrared, Raman, and nuclear magnetic resonance (NMR) spectroscopies and mass spectrometry (MS). Omics-based assessments utilizing MS are rapidly expanding and being applied to various scientific disciplines and clinical settings.
View Article and Find Full Text PDFEnviron Sci Pollut Res Int
October 2023
Anaerobic bioreactors are an efficient technology for the biodegradation of emerging contaminants in environmental matrices. In this work, a horizontal-flow anaerobic immobilized biomass (HAIB) bioreactor was used to remove caffeine (CAF), which is frequently found in various aqueous matrices. The acrylic bench top bioreactor, with dimensions of 100 × 5.
View Article and Find Full Text PDFThe demand for the development of portable and low-cost analytical devices has encouraged studies employing additive manufacturing techniques, such as 3D-printing. This method can be used to produce components such as printed electrodes, photometers, and fluorometers for low-cost systems that provide advantages including low sample volume, reduced chemical waste, and easy coupling with LED-based optics and other instrumental devices. In the present work, a modular 3D-printed fluorometer/photometer was designed and applied for the determination of caffeine (CAF), ciprofloxacin (CIP), and Fe(ii) in pharmaceutical samples.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
June 2022
Thousands of chemical compounds produced by industry are dispersed in the human environment widely enough to reach the world population, and the introduction of new chemicals constantly occurs. As new synthetic molecules emerge, rapid analytical workflows for screening possible presence of exogenous compounds in biofluids can be useful as a first pass analysis to detect chemical exposure and guide the development and application of more elaborate LC-MS/MS methods for quantification. In this study, a suspect screening workflow using the multiple reaction monitoring (MRM) profiling method is proposed as a first pass exploratory technique to survey selected exogenous molecules in human urine samples.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
August 2021
An on-line solid phase extraction using a lab-made restricted access media (RAM) was developed as sample preparation procedure for determination of the pharmaceutical compounds caffeine (CAF), carbamazepine (CBZ), norfloxacin (NOR), ciprofloxacin (CIP), fluoxetine (FLX) and venlafaxine in wastewater treatment plant samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS). This method is suitable for use in routine of analysis, avoiding cross-contamination and requiring only a small sample volume (50 µL), with minimal handling. The method was validated according to international guidelines.
View Article and Find Full Text PDFAn automated method was developed using on-line solid-phase extraction (SPE) as a sample preparation step, coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS), for determination of pharmaceutical compounds in wastewater samples at nanograms per liter to micrograms per liter concentration levels. This method is suitable for use in routine analysis, especially in environmental applications, avoiding cross-contamination and requiring minimal sample handling. Results can be obtained rapidly, with a chromatographic run time of only 24 min (including sample preparation and chromatographic analysis).
View Article and Find Full Text PDFColorimetric techniques have been developed and used in routine analyses for over a century and apparently all their potentialities have been exhaustively explored. However, colorimetric techniques have gained high visibility in the last two decades mainly because of the development of the miniaturization concept, for example, paper-based analytical devices that mostly employ colorimetric reactions, and by the advances and popularity of image capture instruments. The impressive increase in the use of these devices was followed by the development and enhancement of different modes of color detection to meet the demands of making qualitative, semi-quantitative, and fully quantitative analyses of multiple analytes.
View Article and Find Full Text PDFEmerging contaminants, including pharmaceutical compounds, are receiving research attention as a result of their widespread presence in effluents and wastewater treatment plants (WWTPs). The antibiotic ciprofloxacin (CIP) is extensively employed to treat infections in animal and human medicine. Both CIP and its metabolites are common contaminants found in WWTPs.
View Article and Find Full Text PDFIn this study an impedimetric immunosensor was developed in order to determine ciprofloxacin (CIP) in wastewater samples, an emergent contaminant widely found in wastewater. To achieve this, an anti-ciprofloxacin antibody was immobilized on the surface of a printed carbon electrode. Then, the developed immunosensor was applied in wastewater samples from Université Laval residences (Québec, Canada) through the load transfer resistance ( ) using [Fe(CN)] as a redox probe, and the average CIP concentration was found to be 2.
View Article and Find Full Text PDFCaffeine is an element that is consumed worldwide. It is present in many products such as beverages, chocolate, coffee, tea, energy drinks and medicines. Portable 3D devices working together with colorimetric and fluorimetric reactions have been able to determine the presence of caffeine in different kinds of samples.
View Article and Find Full Text PDFJ Hazard Mater
March 2019
The use of anaerobic biomass attached to a support has been recently presented as a good prospect in the treatment of wastewater containing recalcitrant compounds, such as sulfamethazine (SMZ). SMZ has been found in swine wastewater and sewage treatment plants, which motivates assessing their degradation by new wastewater treatment technologies. Thus, this paper describes the use of a continuous fixed structured bed bioreactor for the purpose of evaluating SMZ removal kinetics present in lab-made wastewater.
View Article and Find Full Text PDFThis study presents a new method developed for the simultaneous determination of anionic surfactant (linear alkylbenzene sulfonate - LAS, 4 homologs) and nonionic surfactant (linear alcohol ethoxylate - LAE) in commercial laundry wastewater. The surfactants were identified and quantified using online column-switching solid-phase extraction (SPE) coupled with liquid chromatography/tandem mass spectrometry (LC-MS/MS). Ten and three transitions (m/z) were identified for LAS and LAE, respectively.
View Article and Find Full Text PDFThe antibiotics sulfamethoxazole (SMTX) and ciprofloxacin (CIP) are commonly used in human and veterinary medicine, which explains their occurrence in wastewater. Anaerobic reactors are low-cost, simple and suitable technology to wastewater treatment, but there is a lack of studies related to the removal efficiency of antibiotics. To overcome this knowledge gap, the objective of this study was to evaluate the removal kinetics of SMTX and CIP using a horizontal-flow anaerobic immobilized biomass reactor.
View Article and Find Full Text PDFThis study presents a column-switching solid-phase extraction online-coupled to a liquid chromatography/tandem mass spectrometry (SPE-LC-MS/MS) method for simultaneous analysis of 12 antibiotics (7 sulfonamides and 5 fluoroquinolones) and caffeine detected in the sewage and effluent of a pilot anaerobic reactor used in sewage treatment. After acidification and filtration, the samples were directly injected into a simple and conventional LC system. Backflush and foreflush modes were compared based on the theoretical plates and peak asymmetry observed.
View Article and Find Full Text PDFAnalysis of several emerging contaminants (steroids, caffeine and methylparaben) in water using automated solid-phase microextraction with comprehensive two dimensional gas chromatography coupled to time of flight mass spectrometry (SPME-GCxGC-ToF/MS) is presented. Experimental design was used to determine the best SPME extraction conditions and the steroids were not derivatized prior to injection. SPME-GCxGC-ToF/MS provided linear ranges from 0.
View Article and Find Full Text PDFJ Sep Sci
February 2011
This paper presents the development of a procedure, which enables the analysis of nine pharmaceutical drugs in wastewater using gas chromatography-mass spectrometry (GC-MS) associated with solid-phase microextraction (SPME) for the sample preparation. Experimental design was applied to optimize the in situ derivatization and the SPME extraction conditions. Ethyl chloroformate (ECF) was employed as derivatizing agent and polydimethylsiloxane-divinylbenzene (PDMS-DVB) as the SPME fiber coating.
View Article and Find Full Text PDF