Purpose: The aim of this study concerns the evaluation of peripapillary vessel indices in childhood glaucoma (CG) and healthy subjects.
Material And Methods: In this prospective, unicenter, observational cross-sectional study, patients with CG and age and sex-matched healthy subjects were included. We compared retinal nerve fiber layer (RNFL) measurements in optical coherence tomography (OCT), peripapillary vessel density (PVD), and the flux index (FI) of the superficial vascular plexus from OCT angiography (OCT-A) between CG patients and control groups.
Background/aims: Vascular factors are involved in the development of glaucoma, including diseases such as hypercholesterolemia (HC), systemic arterial hypertension (SAH), and diabetes mellitus (DM). The aim of this study was to determine the effect of glaucoma disease on peripapillary vessel density (sPVD) and macular vessel density (sMVD) on the superficial vascular plexus, controlling differences on comorbidities such as SAH, DM and HC between glaucoma patients and normal subjects.
Methods: In this prospective, unicenter, observational cross-sectional study, sPVD and sMVD were measured in 155 glaucoma patients and 162 normal subjects.
Background/aims: The aim of this study was to assess the optic nerve head (ONH) and macular vessel density with optical coherence tomography angiography (OCT-A) and the ONH haemoglobin (ONH Hb) amount with Laguna ONhE program in open-angle glaucoma (OAG) patients.
Methods: In this prospective observational cross-sectional study, 67 OAG patients and 41 healthy age-sex frequency matched subjects were examined with OCT-A and retinal photos. The circumpapillary (wcpVD), optic nerve head (iVD) and macular (wmVD) capillary vessel density of OCT-A and ONH colorimetric assessment to determine the ONH Hb amount using the Laguna ONhE program were evaluated.
: To evaluate the optic nerve head (ONH), macular vessel density, and retinal nerve fiber layer (RNFL) thickness differences between the genders. : In this prospective case-control cross-sectional study 111 healthy subjects and 130 primary open-angle glaucoma (OAG) patients were examined with optical coherence tomography angiography (OCT-A (RS-3000 Advance (Nidek, Gamagori, Japan))). The vessel density in the peripapillary and macular area as well as the RNFL thickness was evaluated.
View Article and Find Full Text PDFJ Pediatr Ophthalmol Strabismus
January 2020
Purpose: To determine the agreement between intraocular pressure (IOP) measurements obtained using the handheld version of the Goldmann applanation (Perkins; Clement-Clarke, Haag-Streit, Harlow, United Kingdom), rebound Icare-Pro (Icare, Tiolat Oy, Helsinki, Finland), and Tonopen XL (Reichert Inc., Depew, NY) tonometers in children with childhood glaucoma and to identify factors that may affect those measurements.
Methods: Ninety-one eyes of 46 children with early-onset childhood glaucoma were included in this cross-sectional study in which IOP, ocular axial length, anterior chamber depth, lens thickness, vitreous length, and central corneal thickness measurements were obtained under general anesthesia.
J Pediatr Ophthalmol Strabismus
November 2018
Purpose: To compare intraocular pressure (IOP) measurements obtained using the new rebound tonometer Icare-Pro (Icare, Tiolat Oy, Helsinki, Finland) and the hand-held version of the Goldmann applanation tonometer (Perkins; Clement Clarke, Haag-Streit, Harlow, United Kingdom) in healthy children during clinical practice.
Methods: In this prospective study, three IOP measurements were made using each tonometer in a single session, starting with the Icare-Pro. Participants were 173 non-anesthetized patients aged 1 to 16 years.
Significance: Reliable intraocular pressure (IOP) measurement after intrastromal corneal ring segments (ICRS) implantation is a challenge because of altered corneal morphology. In this study, IOP is measured with four tonometers, compared with Goldmann applanation tonometry (GAT) values and the influence of corneal parameters is established.
Purpose: This study compares IOP measurements made using different tonometers in patients implanted with ICRS and assesses the effects of central corneal thickness (CCT), corneal curvature, and corneal astigmatism on the IOP measurements obtained.
Purpose: The computer program laguna onhe determines optic nerve head haemoglobin (ONH Hb) on retinal photographs based on detecting colour differences. This study compares the diagnostic capacity of Laguna ONhE with that of spectral domain optical coherence tomography (OCT) and confocal tomography (HRT III).
Methods: In a prospective, observational, cross-sectional study, glaucomatous (n = 66) and healthy (n = 52) eyes were examined by Spectralis OCT, HRT III and Laguna ONhE.
Purpose: To compare intraocular pressure (IOP) measurements made using 5 tonometers in keratoconic eyes with and without intrastromal corneal ring segments.
Methods And Patients: This was an observational case series study. A total of 147 eyes of 147 patients with keratoconus, 74 of which had undergone corneal ring segment placement, were prospectively evaluated.
Purpose: The aim of this study was to compare intraocular pressure (IOP) measurements in patients with ectatic corneas after intrastromal corneal ring segment (ICRS) implantation using the Rebound tonometers (RBTs) Icare and Icare Pro, compared with Goldmann applanation tonometry (GAT) and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP.
Methods: This prospective cross-sectional study consecutively included 60 eyes of 60 patients with corneal ectasia having ICRS for at least 6 months from January 2011 to December 2013. All subjects underwent GAT, Icare, and Icare Pro IOP measurements in a random order, and CCT, CC, and CA evaluation using a Pentacam.
Purpose: To evaluate intraobserver, interobserver, within-session and between-session reproducibility of the measurement of optic nerve head (ONH) hemoglobin levels by color analysis using Laguna ONhE [optic nerve hemoglobin (ONH Hb)] program.
Materials And Methods: This was an observational prospective study of 29 eyes (11 glaucomatous; 18 healthy eyes). Two examiners obtained 2 retinal photographs (Canon non-mydriatic retinal camera CD-DGi, Canon Inc.