The aim of robot-assisted cochlear implant surgery (RACIS) is to access the inner ear with minimal trauma. High-resolution imaging, empowered with a highly accurate navigation system can enable the planning of a direct keyhole drilling trajectory toward the inner ear. The time has come to (re)define the ideal trajectory into the inner ear with robot-assisted tools that can drill with the highest accuracy.
View Article and Find Full Text PDFBackground: While cochlear implantation (CI) and electric acoustic stimulation (EAS) have a positive outcome in most cases, their effectiveness varies depending on the etiology of the hearing loss. Among the various etiologies, genetic factors are the leading cause of hearing loss and may impact CI and EAS outcomes.
Aims/objectives: To reveal the genetic background of the hearing loss in CI/EAS patients in each ethnic population, we undertook a multi-center study involving the genetic testing of hearing loss in CI/EAS patients from 10 centers.
Objectives: Hearing loss is a worldwide health problem that currently affects around 20% of the world's population. Untreated hearing loss can have a significant impact on daily life, it can cause social isolation, loneliness, frustration, and higher anxiety and depression rates. Furthermore, older adults with hearing impairment have a higher risk for accelerated cognitive decline compared with normal-hearing individuals.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
August 2024
Purpose: To study outcome after cochlear implantation using the Cochlear Implant (CI) outcome assessment protocol based on the International Classification of Functioning, Disability and Health (ICF) model (CI-ICF).
Methods: Raw data of a prospective, longitudinal, multicenter study was analyzed. Seventy-two CI candidates were assessed preoperatively and six months postoperatively using the CI-ICF protocol.
Objectives: Objective measurements to predict the position of a cochlear electrode during cochlear implantation surgery may serve to improve the surgical technique and postoperative speech outcome. There is evidence that electrically evoked compound action potentials (ECAP) are a suitable approach to provide information about the site of stimulation. This study aims to contribute to the knowledge about the association between the intraoperative intracochlear ECAP characteristics and the site of stimulation.
View Article and Find Full Text PDFObjective: The suitable electrode array choice is broadly discussed in cochlear implantation surgery. Whether to use a shorter electrode length under the aim of structure preservation versus choosing a longer array to achieve a greater cochlear coverage is a matter of debate. The aim of this review is to identify the impact of the insertion depth of a cochlear implant (CI) electrode array on CI users' speech perception outcomes.
View Article and Find Full Text PDFImportance: The development of a vestibular implant has reached milestones and seems to be a promising therapeutic tool for bilateral vestibulopathy (BV). Given the former lack of therapeutic options for BV, the disease has received scant attention in the previous research literature. It is therefore of major importance to gain more insight into the underlying pathology of BV.
View Article and Find Full Text PDFThis paper provides a step-by-step guide for organizing the scientific program (OSP) of international conferences. Through informal discussions, a panel of experts organizing international conferences came up with this guide, which includes a flowchart, checklist, and detailed discussions of each step. Subsequently, additional specialists were invited to evaluate this synopsis and provide their input.
View Article and Find Full Text PDFInt J Environ Res Public Health
October 2023
This study aimed to report quality of life (QoL) scores in unilateral cochlear implant (CI) users and to generate guidance for clinicians on using QoL measures to individualize CI counselling and rehabilitation and to increase access to CIs as a mode of rehabilitation. Participants (n = 101) were unilateral CI users with single-sided deafness (SSD; n = 17), asymmetrical hearing loss (AHL; n = 26), or bilateral hearing loss (Uni; n = 58). Generic QoL was assessed via the Health Utilities Index (HUI-3), and disease-specific QoL was assessed via the Speech, Spatial, and Qualities of Hearing scale (SSQ12) and Nijmegen CI Questionnaire (NCIQ) at preimplantation and at 6 and 12 months of CI use.
View Article and Find Full Text PDFImpedance measurements are routinely performed during cochlear implantation (CI) after finalized electrode insertion. They may allow conclusions on the electrode's and implant's function. In the postoperative setting, the analysis of impedance changes enables the identification of scarring or inflammation processes around the electrode.
View Article and Find Full Text PDFObjective: In cochlear implantation with flexible lateral wall electrodes, a cochlear coverage of 70% to 80% is assumed to yield an optimal speech perception. Therefore, fitting the cochlear implant (CI) to the patient's individual anatomy has gained importance in recent years. For these reasons, the optimal angular insertion depth (AID) has to be calculated before cochlear implantation.
View Article and Find Full Text PDFPurpose: Giant prolactinomas are a rare entity, representing approximately 5% of all prolactinomas. A systematic review of 196 adult cases was performed. A comparison of the clinical, biochemical and radiological characteristics, management and therapeutic outcomes in men versus women is made.
View Article and Find Full Text PDFPurpose: In cochlear implantation with flexible lateral wall electrode arrays, a cochlear coverage (CC) range between 70% and 80% is considered ideal for optimal speech perception. To achieve this CC, the cochlear implant (CI) electrode array has to be chosen according to the individual cochlear duct length (CDL). Here, we mathematically analyzed the suitability of different flexible lateral wall electrode array lengths covering between 70% and 80% of the CDL.
View Article and Find Full Text PDFObjective: Tinnitus can be regarded as a chronic stressor, leading to dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis. There is important comorbidity with anxiety, particularly panic, potentially associated with differences in HPA axis functioning and methylation patterns of HPA axis-related genes. This study examines DNA methylation of the glucocorticoid receptor gene ( NR3C1 ) exon 1F in adults with chronic subjective tinnitus and the possible differential effect of panic.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
October 2023
Purpose: The main objective of this study is to evaluate the short-term and long-term audiological outcomes in patients who underwent cochlear implantation with a robot-assisted system to enable access to the cochlea, and to compare outcomes with a matched control group of patients who underwent cochlear implantation with conventional access to the cochlea.
Methods: In total, 23 patients were implanted by robot-assisted cochlear implant surgery (RACIS). To evaluate the effectiveness of robotic surgery in terms of audiological outcomes, a statistically balanced control group of conventionally implanted patients was created.
Objective: To evaluate the safety and efficacy of AM-125 nasal spray (intranasal betahistine) in the treatment of surgery-induced acute vestibular syndrome (AVS).
Study Design: Prospective, double-blind, randomized, placebo-controlled exploratory phase 2 study with dose escalation (part A) followed by parallel dose testing (part B); open-label oral treatment for reference.
Setting: Twelve European study sites (tertiary referral centers).
Background: The benefit of hearing rehabilitation is often measured using audiological tests or subjective questionnaires/interviews. It is important to consider both aspects in order to evaluate the overall benefits. Currently, there is no standardized method for reporting combined audiological and patient reported subjective outcome measures in clinical practice.
View Article and Find Full Text PDFCochlear implantation (CI) for deafblindness may have more impact than for non-syndromic hearing loss. Deafblind patients have a double handicap in a society that is more and more empowered by fast communication. CI is a remedy for deafness, but requires revision surgery every 20 to 25 years, and thus placement should be minimally invasive.
View Article and Find Full Text PDFImportance: Given the rapidly rising dementia incidence, management of modifiable risk factors, such as hearing loss, is vital. Multiple studies have demonstrated an improvement of cognitive functioning in older adults with severe hearing loss after cochlear implantation; however, few of these studies, to the authors' knowledge, specifically analyzed participants achieving poor cognitive results preoperatively.
Objective: To evaluate the cognitive functioning of older adults with severe hearing loss at risk for mild cognitive impairment (MCI) before and after cochlear implantation.
Laryngoscope Investig Otolaryngol
December 2022
Objective: We hypothesize that visualizing inner-ear systematically in both cochlear view (oblique coronal plane) and in mid-modiolar section (axial plane) and following three sequential steps simplifies, identification of inner-ear malformation types.
Methods: Pre-operative computer-tomography (CT) scans of temporal bones of 112 ears with various inner ear malformation (IEM) types were taken for analysis. Images were analyzed using DICOM viewers, 3D slicer, and OTOPLAN®.