Small, preliminary studies have suggested that capnograms of obstructive lung disease (OD) exhibit a characteristic shape and that this shape may be correlated to changes in forced expiratory volume in 1 s (FEV(1)). We evaluated the association between capnograms and spirometry from subjects with OD with normal and restrictive lung disease (RD) subjects. The study was conducted in a prospective, nonrandomized manner using a convenience sample of 262 subjects presenting to a pulmonary function laboratory.
View Article and Find Full Text PDFObjective: This clinical study prospectively evaluated the first-shock defibrillation efficacy of 150-joule impedance-compensated, 200-microF biphasic truncated exponential (BTE) shocks in patients with electrically-induced ventricular fibrillation (VF), and compared it with a historical control group treated with 200-J monophasic damped sine (MDS) shocks.
Methods: Ventricular tachyarrhythmias were induced in patients undergoing electrophysiologic (EP) testing for ventricular arrhythmias or testing of an implantable cardioverter-defibrillator (ICD). A 150-J shock was delivered as the primary therapy to terminate induced arrhythmias in the EP group, and as a "rescue" shock when a single ICD shock failed to terminate the arrhythmias in the ICD group.
Background: We compared efficacy of and pain felt after biphasic truncated exponential (BTE) and monophasic damped sine (MDS) shocks in patients undergoing external cardioversion of atrial fibrillation (AF).
Methods: Patients with AF were randomized to BTE or MDS waveform cardioversion. Successive shocks were delivered at 70, 100, 200, and 360 J until successful cardioversion, with one 360 J attempt of the alternate waveform when all 4 shocks failed.
Background: Biphasic waveform shocks are more effective than monophasic shocks for transchest ventricular defibrillation, atrial cardioversion, and defibrillation with implantable defibrillators but have not been studied for open chest, intraoperative defibrillation. This prospective, blinded, randomized clinical study compares biphasic and monophasic shock effectiveness and establishes intraoperative energy dose-response curves.
Methods: Patients undergoing cardiothoracic surgery with bypass cardioplegia were randomly assigned to the monophasic or biphasic shock group.
Background: External defibrillation has long been practiced with two types of monophasic waveforms, and now four biphasic waveforms are also widely available. Although waveforms and clinical dosing protocols differ among defibrillators, no studies have adequately compared performance of the monophasic or the biphasic waveforms. This is the first study to compare defibrillation efficacy among biphasic external defibrillators, and does so as part of a study comparing all commonly available waveforms using their respective manufacturer-provided and clinically used doses.
View Article and Find Full Text PDF