As a promising energy- and carbon efficient process for nitrogen removal from wastewater, mainstream nitrite shunt has been extensively researched. However, beyond the laboratory it is challenging to maintain stable performance by suppressing nitrite-oxidising bacteria (NOB). In this study, a pilot-scale reactor system receiving real sewage was operated in two stages for >850 days to evaluate two novel NOB suppression strategies for achieving nitrite shunt: i) sidestream sludge treatment based on alternating free nitrous acid (FNA) and free ammonia (FA) and ii) sidestream FNA/FA sludge treatment integrated with in-situ NOB suppression via step-feed.
View Article and Find Full Text PDFRetention in care remains an important concern for health care providers. However, accurately identifying who is or is not retained in care can be problematic. Not all patients believed to be engaged in care are actually in care, and not all patients believed to be disengaged are truly disengaged.
View Article and Find Full Text PDFThis study demonstrates the full scale application of iron dosing in a metropolitan wastewater treatment plant (WWTP) and the upstream sewer system for multiple benefits. Two different dosing locations, i.e.
View Article and Find Full Text PDFIron and aluminium based coagulants are used in enormous amounts and play an essential role in urban water management globally. They are dosed at drinking water production facilities for the removal of natural organic matter. Iron salts are also dosed to sewers for corrosion and odour control, and at wastewater treatment plants (WWTPs) for phosphate removal from wastewater and hydrogen sulfide removal from biogas.
View Article and Find Full Text PDF