A low-cost second harmonic generation (SHG) microscope was constructed, and, for the first time, SHG microscopy was used for imaging agrochemical materials directly on the surface of common commercial crop leaves. The microscope uses a chromatically fixed (1560 nm) femtosecond fiber laser, a commercial 2D galvanometer mirror system, and a PCIe digital oscilloscope card, which together kept total instrument costs under $40 000 (USD), a significant decrease in cost and complexity from common systems (commercial and home-built) using tunable lasers and faster beam-scanning architectures. The figures of merit of the low-cost system still enabled a variety of measurements of agrochemical materials.
View Article and Find Full Text PDFA statistical model enables auto-calibration of second harmonic generation (SHG) images for quantifying trace crystallinity within amorphous solid dispersions (ASDs) over a wide dynamic range of crystallinity. In this paper, we demonstrate particle-counting approaches for quantifying trace crystallinity, combined with analytical expressions correcting for particle overlap bias in higher crystallinity regimes to extend the continuous dynamic range of standard particle-counting algorithms through to the signal averaging regime. The reliability of the values recovered by these expressions was demonstrated with simulated data as well as experimental data obtained for an amorphous solid dispersion formulation containing evacetrapib, an Eli Lilly and Company compound.
View Article and Find Full Text PDFVarious techniques have been used to detect crystallization in amorphous solid dispersions (ASD). However, most of these techniques do not enable the detection of very low levels of crystallinity (<1%). The aim of the current study was to compare the sensitivity of second harmonic generation (SHG) microscopy with powder X-ray diffraction (XRPD) in detecting the presence of crystals in low drug loading amorphous solid dispersions.
View Article and Find Full Text PDFThe past decade has seen an increase in the use of nonlinear optical (NLO) techniques such as second harmonic generation, coherent antistokes Raman scattering, stimulated Raman scattering, and two-photon fluorescence for the solid-state characterization of pharmaceutical materials. These combined techniques offer several advantages (e.g.
View Article and Find Full Text PDFNonlinear optical Stokes ellipsometric (NOSE) microscopy was demonstrated for the analysis of collagen-rich biological tissues. NOSE is based on polarization-dependent second harmonic generation imaging. NOSE was used to access the molecular-level distribution of collagen fibril orientation relative to the local fiber axis at every position within the field of view.
View Article and Find Full Text PDFThe use of nonlinear optical Stokes ellipsometric (NOSE) microscopy for rapid discrimination of two polymorphic forms of the small molecule d-mannitol is presented. Fast (8 MHz) polarization modulated beam-scanning microscopy and a recently developed iterative, nonlinear least-squares fitting algorithm were combined to allow discrimination of orthorhombic and monoclinic crystal structures of d-mannitol with data acquisition times of <7 s per field of view with a signal-to-noise ratio (SNR) of ∼300. Discrimination between polymorphic forms within the 99.
View Article and Find Full Text PDFFast beam-scanning non-linear optical microscopy, coupled with fast (8 MHz) polarization modulation and analytical modeling have enabled simultaneous nonlinear optical Stokes ellipsometry (NOSE) and linear Stokes ellipsometry imaging at video rate (15 Hz). NOSE enables recovery of the complex-valued Jones tensor that describes the polarization-dependent observables, in contrast to polarimetry, in which the polarization stated of the exciting beam is recorded. Each data acquisition consists of 30 images (10 for each detector, with three detectors operating in parallel), each of which corresponds to polarization-dependent results.
View Article and Find Full Text PDFHere we demonstrate the use of second harmonic generation (SHG) microscopy-guided synchrotron powder X-ray diffraction (PXRD) for the detection of trace crystalline active pharmaceutical ingredients in a common polymer blend. The combined instrument is capable of detecting 100 ppm crystalline ritonavir in an amorphous hydroxypropyl methylcellulose matrix with a high signal-to-noise ratio (>5000). The high spatial resolution afforded by SHG microscopy allows for the use of a minibeam collimator to reduce the total volume of material probed by synchrotron PXRD.
View Article and Find Full Text PDFSecond harmonic generation (SHG) microscopy was used to rapidly identify regions of interest for localized confocal Raman spectroscopy measurements in order to quantify crystallinity within lyophilized Abraxane powder (protein bound paclitaxel for injectable suspension). Water insoluble noncentrosymmetric crystalline particles ranging from ∼1 to 120 μm were identified by SHG, with wide variability in crystal size and frequency observed between several batches of Abraxane. By targeting the Raman analysis to these localized regions identified by SHG, the required measurement time was decreased over 2 orders of magnitude, from 8 h to 2 s.
View Article and Find Full Text PDFFast 8 MHz polarization modulation coupled with analytical modeling, fast beam-scanning, and synchronous digitization (SD) have enabled simultaneous nonlinear optical Stokes ellipsometry (NOSE) and polarized laser transmittance imaging with image acquisition rates up to video rate. In contrast to polarimetry, in which the polarization state of the exiting beam is recorded, NOSE enables recovery of the complex-valued Jones tensor of the sample that describes all polarization-dependent observables of the measurement. Every video-rate scan produces a set of 30 images (10 for each detector with three detectors operating in parallel), each of which corresponds to a different polarization-dependent result.
View Article and Find Full Text PDFA digital filter derived from linear discriminant analysis (LDA) is developed for recovering impulse responses in photon counting from a high speed photodetector (rise time of ~1 ns) and applied to remove ringing distortions from impedance mismatch in multiphoton fluorescence microscopy. Training of the digital filter was achieved by defining temporally coincident and noncoincident transients and identifying the projection within filter-space that best separated the two classes. Once trained, data analysis by digital filtering can be performed quickly.
View Article and Find Full Text PDF