Publications by authors named "Paul D Jager"

Jenike's approach to hopper design for a large-scale (3150 L) conical hopper was applied to pharmaceutical powders to evaluate flow issues, such as funnel flow or cohesive arching. Seven grades of microcrystalline cellulose (MCC) and six powder blends were tested. A Schulze Ring Shear Tester measured the flow function, wall friction (using stainless steel coupons with a #2B or #8 finish) and compressibility.

View Article and Find Full Text PDF