J Clin Monit Comput
April 2013
External leg compression (ELC) may increase cardiac output (CO) in fluid-responsive patients like passive leg raising (PLR). We compared the hemodynamic effects of two methods of ELC and PLR measured by thermodilution (COtd), pressure curve analysis Modelflow™ (COmf) and ultra-sound HemoSonic™ (COhs), to evaluate the method with the greatest hemodynamic effect and the most accurate less invasive method to measure that effect. We compared hemodynamic effects of two different ELC methods (circular, A (n = 16), vs.
View Article and Find Full Text PDFBackground: Mathematical coupling may explain in part why cardiac filling volumes obtained by transpulmonary thermodilution may better predict and monitor responses of cardiac output to fluid loading than pressures obtained by pulmonary artery catheters (PACs).
Methods: Eleven consecutive patients with hypovolaemia after coronary surgery and a PAC, allowing central venous pressure (CVP) and continuous cardiac index (CCIp) measurements, received a femoral artery catheter for transpulmonary thermodilution measurements of global end-diastolic blood volume index (GEDVI) and cardiac index (CItp). One to five colloid fluid-loading steps of 250 ml were done in each patient (n = 48 total).
Objective: To measure the relationship between blood flow and central venous pressure (Pcv) and to estimate mean systemic filling pressure (Pmsf), circulatory compliance, and stressed volume in patients in the intensive care unit.
Design: Intervention study.
Setting: Intensive care unit of a university hospital.
Background And Aims: Cardiac function may differ after valvular (VS) and coronary artery (CAS) surgery and this may affect assessment of fluid responsiveness. The aim of the study was to compare VS and CAS in the value of cardiac filling pressures and volumes herein.
Methods: There were eight consecutive patients after VS and eight after CAS, with femoral and pulmonary artery catheters in place.
J Appl Physiol (1985)
March 2002
The hemodynamic effects of increases in airway pressure (Paw) are related in part to Paw-induced increases in right atrial pressure (Pra), the downstream pressure for venous return, thus decreasing the pressure gradient for venous return. However, numerous animal and clinical studies have shown that venous return is often sustained during ventilation with positive end-expiratory pressure (PEEP). Potentially, PEEP-induced diaphragmatic descent increases abdominal pressure (Pabd).
View Article and Find Full Text PDF