We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage.
View Article and Find Full Text PDFThe bistable electroactive polymer is a new smart material capable of large strain, rigid-to-rigid actuation. At the rubbery state of the polymer heated to above its glass transition, stable electrically-induced actuation is obtained at strains as large as 150%. Electromechanical instability can be effectively overcome by the formation of interpenetrating polymer networks.
View Article and Find Full Text PDFA new compliant electrode-based on silver nanowire-polymer composite has been developed. The composite electrode has low sheet resistance (as low as 10 Ω/sq), remains conductive (10(2) -10(3) Ω/sq) at strains as high as 140%, and can support Joule heating. The combination of the composite and a bistable electroactive polymer produces electrically-induced, large-strain actuation and relaxation, reversibly without the need of mechanical programming.
View Article and Find Full Text PDFObjectives: Although differential exposure by socioeconomic position (SEP) to hazardous waste and lead is well demonstrated, there is less evidence for particulate air pollution (PM), which is associated with risk of death and illness. This study determined the relationship of ambient PM and SEP across several spatial scales.
Methods: Geographic information system-based, spatio-temporal models were used to predict PM in the Northeastern United States.
Macromol Rapid Commun
January 2010
A number of materials have been explored for their use as artificial muscles. Among these, dielectric elastomers (DEs) appear to provide the best combination of properties for true muscle-like actuation. DEs behave as compliant capacitors, expanding in area and shrinking in thickness when a voltage is applied.
View Article and Find Full Text PDFSuitable detectors are needed to support survey needs of incident responders and health care personnel who may receive patients from an incident with exposures to hazardous chemicals. In the health care setting, such a detector would avoid cross-contamination to workers, patients, and to the treatment facility and associated equipment. An ideal survey detector would be sensitive, hand-held, capable of extended battery operation, and would provide a nearly immediate detector response on exposure to a broad range of high-concern chemicals.
View Article and Find Full Text PDF