Publications by authors named "Paul Blount"

Understanding how bacteria respond to ventilated environments is a crucial concept, especially when considering accurate airflow modeling and detection limits. To properly design facilities for aseptic conditions, we must minimize the parameters for pathogenic bacteria to thrive. Identifying how pathogenic bacteria continue to survive, particularly due to their multi-drug resistance characteristics, is necessary for designing sterile environments and minimizing pathogen exposure.

View Article and Find Full Text PDF

Resistance to antibiotics is a serious and worsening threat to human health worldwide, and there is an urgent need to develop new antibiotics that can avert it. One possible solution is the development of compounds that possess multiple modes of action, requiring at least two mutations to acquire resistance. Compound SCH-79797 both avoids resistance and has two mechanisms of action: one inhibiting the folate pathway, and a second described as "membrane permeabilization"; however, the mechanism by which membranes from bacterial cells, but not the host, are disrupted has remained mysterious.

View Article and Find Full Text PDF

MscL is a highly conserved mechanosensitive channel found in the majority of bacterial species, including pathogens. It functions as a biological emergency release valve, jettisoning solutes from the cytoplasm upon acute hypoosmotic stress. It opens the largest known gated pore and has been heralded as an antibacterial target.

View Article and Find Full Text PDF

Curcumin, a natural compound isolated from the rhizome of turmeric, has been shown to have antibacterial properties. It has several physiological effects on bacteria including an apoptosis-like response involving RecA, membrane permeabilization, inhibiting septation, and it can also work synergistically with other antibiotics. The mechanism by which curcumin permeabilizes the bacterial membrane has been unclear.

View Article and Find Full Text PDF

Mechanosensitive channels respond to mechanical forces exerted on the cell membrane and play vital roles in regulating the chemical equilibrium within cells and their environment. High-resolution structural information is required to understand the gating mechanisms of mechanosensitive channels. Protein-lipid interactions are essential for the structural and functional integrity of mechanosensitive channels, but detergents cannot maintain the crucial native lipid environment for purified mechanosensitive channels.

View Article and Find Full Text PDF

Proteoliposomes mimic the cell membrane environment allowing for structural and functional membrane protein analyses as well as antigen presenting and drug delivery devices. To make proteoliposomes, purified functional membrane proteins are required. Detergents have traditionally been used for the first step in this process However, they can irreversibly denature or render membrane proteins unstable, and the necessary removal of detergents after reconstitution can decrease proteoliposome yields.

View Article and Find Full Text PDF

Although extracellular force has a profound effect on cell shape, cytoskeleton tension, and cell proliferation through the Hippo signaling effector Yki/YAP/TAZ, how intracellular force regulates these processes remains poorly understood. Here, we report an essential role for spectrin in specifying cell shape by transmitting intracellular actomyosin force to cell membrane. While activation of myosin II in Drosophila melanogaster pupal retina leads to increased cortical tension, apical constriction, and Yki-mediated hyperplasia, spectrin mutant cells, despite showing myosin II activation and Yki-mediated hyperplasia, paradoxically display decreased cortical tension and expanded apical area.

View Article and Find Full Text PDF

The antibiotic resistance crisis is becoming dire, yet in the past several years few potential antibiotics or adjuvants with novel modes of action have been identified. The bacterial mechanosensitive channel of large conductance, MscL, found in the majority of bacterial species, including pathogens, normally functions as an emergency release valve, sensing membrane tension upon low-osmotic stress and discharging cytoplasmic solutes before cell lysis. Opening the huge ~30Å diameter pore of MscL inappropriately is detrimental to the cell, allowing solutes from and even passage of drugs into to cytoplasm.

View Article and Find Full Text PDF

General principles in biology have often been elucidated from the study of bacteria. This is true for the bacterial mechanosensitive channel of large conductance, MscL, the channel highlighted in this review. This channel functions as a last-ditch emergency release valve discharging cytoplasmic solutes upon decreases in osmotic environment.

View Article and Find Full Text PDF

The bacterial MscL channel normally functions as an emergency release valve discharging cytoplasmic solutes upon osmotic stress. The channel opens and passes molecules up to 30 Å and its pore is the largest of any gated channel. Opening the MscL pore inappropriately is detrimental to the bacterial cell, suggesting MscL as a potential novel drug target.

View Article and Find Full Text PDF

All membrane proteins have dynamic and intimate relationships with the lipids of the bilayer that may determine their activity. Mechanosensitive channels sense tension through their interaction with the lipids of the membrane. We have proposed a mechanism for the bacterial channel of small conductance, MscS, that envisages variable occupancy of pockets in the channel by lipid chains.

View Article and Find Full Text PDF

An adequate response of a living cell to the ever-changing environment requires integration of numerous sensory inputs. In many cases, it can be achieved even at the level of a single receptor molecule. Polymodal transient receptor potential (TRP) channels have been shown to integrate mechanical, chemical, electric, and thermal stimuli.

View Article and Find Full Text PDF

The ability to reversibly and non-invasively modulate region-specific brain activity in vivo suggests Low Intensity Focused Ultrasound (LIFU) as potential therapeutics for neurological dysfunctions such as epilepsy and Parkinson's disease. While in vivo studies provide evidence of the bioeffects of LIFU on neuronal activity, they merely hint at potential mechanisms but do not fully explain how this technology achieves these effects. One potential hypothesis is that LIFU produces local membrane depolarization by mechanically perturbing the neuronal cell membrane, or activating channels or other proteins embedded in the membrane.

View Article and Find Full Text PDF

The bacterial mechanosensitive channel of large conductance (MscL) normally functions as an emergency release valve discharging cytoplasmic solutes upon osmotic stress. Opening the large pore of MscL inappropriately is detrimental to the cell, and thus it has been speculated to be a potential antibiotic target. Although MscL is one of the best studied mechanosensitive channels, no chemical that influenced bacterial growth by modulating MscL is known.

View Article and Find Full Text PDF

MscL is a bacterial mechanosensitive channel that serves as a cellular emergency release valve, protecting the cell from lysis upon a drop in external osmolarity. The channel has an extremely large pore (30 Å) and can be purified and reconstituted into artificial membranes. Moreover, MscL is modified to open in response to alternative external stimuli including changes in pH.

View Article and Find Full Text PDF

The primary mechanism of action of the antibiotic dihydrostreptomycin is binding to and modifying the function of the bacterial ribosome, thus leading to decreased and aberrant translation of proteins; however, the routes by which it enters the bacterial cell are largely unknown. The mechanosensitive channel of large conductance, MscL, is found in the vast majority of bacterial species, where it serves as an emergency release valve rescuing the cell from sudden decreases in external osmolarity. While it is known that MscL expression increases the potency of dihydrostreptomycin, it has remained unclear if this effect is due to a direct interaction.

View Article and Find Full Text PDF

Mechanosensitive channels are present in all living organisms and are thought to underlie the senses of touch and hearing as well as various important physiological functions like osmoregulation and vasoregulation. The mechanosensitive channel of large conductance (MscL) from Escherichia coli was the first protein shown to encode mechanosensitive channel activity and serves as a paradigm for how a channel senses and responds to mechanical stimuli. MscL plays a role in osmoprotection in E.

View Article and Find Full Text PDF

In Escherichia coli (E. coli) the mechanosensitive channel of small conductance, MscS, gates in response to membrane tension created from acute external hypoosmotic shock, thus rescuing the bacterium from cell lysis. E.

View Article and Find Full Text PDF

The growing problem of antibiotic-resistant bacteria is a major threat to human health. Paradoxically, new antibiotic discovery is declining, with most of the recently approved antibiotics corresponding to new uses for old antibiotics or structurally similar derivatives of known antibiotics. We used an in silico approach to design a new class of nontoxic antimicrobials for the bacteria-specific mechanosensitive ion channel of large conductance, MscL.

View Article and Find Full Text PDF

Phenotypical analysis of the lipid interacting residues in the closed state of the mechanosensitive channel of small conductance (MscS) from Escherichia coli (E. coli) has previously shown that these residues are critical for channel function. In the closed state, mutation of individual hydrophobic lipid lining residues to alanine, thus reducing the hydrophobicity, resulted in phenotypic changes that were observable using in vivo assays.

View Article and Find Full Text PDF

The bacterial mechanosensitive channel of large conductance (MscL) serves as a biological emergency release valve, preventing the occurrence of cell lysis caused by acute osmotic stress. Its tractable nature allows it to serve as a paradigm for how a protein can directly sense membrane tension. Although much is known of the importance of the hydrophobicity of specific residues in channel gating, it has remained unclear whether electrostatics at the membrane plays any role.

View Article and Find Full Text PDF

The antibiotic streptomycin is widely used in the treatment of microbial infections. The primary mechanism of action is inhibition of translation by binding to the ribosome, but how it enters the bacterial cell is unclear. Early in the study of this antibiotic, a mysterious streptomycin-induced potassium efflux preceding any decrease in viability was observed; it was speculated that this changed the electrochemical gradient such that streptomycin better accessed the cytoplasm.

View Article and Find Full Text PDF

MscL, the highly conserved bacterial mechanosensitive channel of large conductance, is one of the best studied mechanosensors. It is a homopentameric channel that serves as a biological emergency release valve that prevents cell lysis from acute osmotic stress. We previously showed that the periplasmic region of the protein, particularly a single residue located at the TM1/periplasmic loop interface, F47 of Staphylococcus aureus and I49 of Escherichia coli MscL, plays a major role in both the open dwell time and mechanosensitivity of the channel.

View Article and Find Full Text PDF

The bacterial mechanosensitive channel of large conductance (MscL) directly senses and responds to membrane tension. It serves as an "emergency release valve" upon acute decreases in the osmotic environment, thus preventing cell lysis. It is one of the best studied mechanosensitive channels and serves as a paradigm of how a channel senses and responds to its membrane environment.

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=28 No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/lib/php/sessions)

Filename: Unknown

Line Number: 0

Backtrace: