J Diabetes Sci Technol
September 2024
Background: Despite abundant evidence demonstrating the benefits of continuous glucose monitoring (CGM) in diabetes management, a significant proportion of people using this technology still struggle to achieve glycemic targets. To address this challenge, we propose the Accu-Chek SmartGuide Predict app, an innovative CGM digital companion that incorporates a suite of advanced glucose predictive functionalities aiming to inform users earlier about acute glycemic situations.
Methods: The app's functionalities, powered by three machine learning models, include a two-hour glucose forecast, a 30-minute low glucose detection, and a nighttime low glucose prediction for bedtime interventions.
Objective: Artificial intelligence and machine learning are transforming many fields including medicine. In diabetes, robust biosensing technologies and automated insulin delivery therapies have created a substantial opportunity to improve health. While the number of manuscripts addressing the topic of applying machine learning to diabetes has grown in recent years, there has been a lack of consistency in the methods, metrics, and data used to train and evaluate these algorithms.
View Article and Find Full Text PDFBackground: One of the biggest challenges for people with type 1 diabetes (T1D) using multiple daily injections (MDIs) is nocturnal hypoglycemia (NH). Recurrent NH can lead to serious complications; hence, prevention is of high importance. In this work, we develop and externally validate, device-agnostic Machine Learning (ML) models to provide bedtime decision support to people with T1D and minimize the risk of NH.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
October 2023
Time series data generated by continuous glucose monitoring sensors offer unparalleled opportunities for developing data-driven approaches, especially deep learning-based models, in diabetes management. Although these approaches have achieved state-of-the-art performance in various fields such as glucose prediction in type 1 diabetes (T1D), challenges remain in the acquisition of large-scale individual data for personalized modeling due to the elevated cost of clinical trials and data privacy regulations. In this work, we introduce GluGAN, a framework specifically designed for generating personalized glucose time series based on generative adversarial networks (GANs).
View Article and Find Full Text PDFThe Advanced Bolus Calculator for Type 1 Diabetes (ABC4D) is a decision support system using the artificial intelligence technique of case-based reasoning to adapt and personalize insulin bolus doses. The integrated system comprises a smartphone application and clinical web portal. We aimed to assess the safety and efficacy of the ABC4D (intervention) compared with a nonadaptive bolus calculator (control).
View Article and Find Full Text PDFFront Bioeng Biotechnol
October 2022
Sub-therapeutic dosing of piperacillin-tazobactam in critically-ill patients is associated with poor clinical outcomes and may promote the emergence of drug-resistant infections. In this paper, an investigation of whether closed-loop control can improve pharmacokinetic-pharmacodynamic (PK-PD) target attainment is described. An platform was developed using PK data from 20 critically-ill patients receiving piperacillin-tazobactam where serum and tissue interstitial fluid (ISF) PK were defined.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
January 2023
The availability of large amounts of data from continuous glucose monitoring (CGM), together with the latest advances in deep learning techniques, have opened the door to a new paradigm of algorithm design for personalized blood glucose (BG) prediction in type 1 diabetes (T1D) with superior performance. However, there are several challenges that prevent the widespread implementation of deep learning algorithms in actual clinical settings, including unclear prediction confidence and limited training data for new T1D subjects. To this end, we propose a novel deep learning framework, Fast-adaptive and Confident Neural Network (FCNN), to meet these clinical challenges.
View Article and Find Full Text PDFPeople living with type 1 diabetes (T1D) require lifelong self-management to maintain glucose levels in a safe range. Failure to do so can lead to adverse glycemic events with short and long-term complications. Continuous glucose monitoring (CGM) is widely used in T1D self-management for real-time glucose measurements, while smartphone apps are adopted as basic electronic diaries, data visualization tools, and simple decision support tools for insulin dosing.
View Article and Find Full Text PDFTo determine if a longer duration of continuous glucose monitoring (CGM) sampling is needed to correctly assess the quality of glycemic control given different types of data loss. Data loss was generated in two different methods until the desired percentage of data loss (10-50%) was achieved with (1) eliminating random individual CGM values and (2) eliminating gaps of a predefined time length (1-5 h). For CGM metrics, days required to cross predetermined targets for median absolute percentage error (MdAPE) for the different data loss strategies were calculated and compared with current international consensus recommendation of >70% of optimal data sampling.
View Article and Find Full Text PDFDiabetes Technol Ther
June 2022
The recent increase in wearable devices for diabetes care, and in particular the use of continuous glucose monitoring (CGM), generates large data sets and associated cybersecurity challenges. In this study, we demonstrate that it is possible to identify CGM data at an individual level by using standard machine learning techniques. The publicly available REPLACE-BG data set (NCT02258373) containing 226 adult participants with type 1 diabetes (T1D) wearing CGM over 6 months was used.
View Article and Find Full Text PDFCurrent artificial pancreas (AP) systems are hybrid closed-loop systems that require manual meal announcements to manage postprandial glucose control effectively. This poses a cognitive burden and challenge to users with T1D since this relies on frequent user engagement to maintain tight glucose control. In order to move towards fully automated closed-loop glucose control, we propose an algorithm based on a deep learning framework that performs multitask quantile regression, for both meal detection and carbohydrate estimation.
View Article and Find Full Text PDFBackground: User-developed automated insulin delivery systems, also referred to as do-it-yourself artificial pancreas systems (DIY APS), are in use by people living with type 1 diabetes. In this work, we evaluate, in silico, the DIY APS Loop control algorithm and compare it head-to-head with the bio-inspired artificial pancreas (BiAP) controller for which clinical data are available.
Methods: The Python version of the Loop control algorithm called PyLoopKit was employed for evaluation purposes.
IEEE J Biomed Health Inform
January 2022
Blood glucose prediction algorithms are key tools in the development of decision support systems and closed-loop insulin delivery systems for blood glucose control in diabetes. Deep learning models have provided leading results among machine learning algorithms to date in glucose prediction. However these models typically require large amounts of data to obtain best personalised glucose prediction results.
View Article and Find Full Text PDFBackground: Bacterial infection has been challenging to diagnose in patients with COVID-19. We developed and evaluated supervised machine learning algorithms to support the diagnosis of secondary bacterial infection in hospitalized patients during the COVID-19 pandemic.
Methods: Inpatient data at three London hospitals for the first COVD-19 wave in March and April 2020 were extracted.
Nat Rev Microbiol
December 2021
An optimal antimicrobial dose provides enough drug to achieve a clinical response while minimizing toxicity and development of drug resistance. There can be considerable variability in pharmacokinetics, for example, owing to comorbidities or other medications, which affects antimicrobial pharmacodynamics and, thus, treatment success. Although current approaches to antimicrobial dose optimization address fixed variability, better methods to monitor and rapidly adjust antimicrobial dosing are required to understand and react to residual variability that occurs within and between individuals.
View Article and Find Full Text PDFComput Methods Programs Biomed
September 2021
Background: There are several medical devices used in Colombia for diabetes management, most of which have an associated telemedicine platform to access the data. In this work, we present the results of a pilot study evaluating the use of the Tidepool telemedicine platform for providing remote diabetes health services in Colombia across multiple devices.
Method: Individuals with Type 1 and Type 2 diabetes using multiple diabetes devices were recruited to evaluate the user experience with Tidepool over three months.
Diabetes is a chronic metabolic disorder that affects an estimated 463 million people worldwide. Aiming to improve the treatment of people with diabetes, digital health has been widely adopted in recent years and generated a huge amount of data that could be used for further management of this chronic disease. Taking advantage of this, approaches that use artificial intelligence and specifically deep learning, an emerging type of machine learning, have been widely adopted with promising results.
View Article and Find Full Text PDFConsensus continuous glucose monitoring (CGM) guidance includes a recommendation that a minimum of 14 days of CGM data are used to report times in ranges. The previously employed approaches to determine the optimal duration for CGM data have limitations. In this study, we present a robust approach to define the minimum duration of CGM data to report times in ranges, as well as other glycemic metrics.
View Article and Find Full Text PDFThe Patient Empowerment through Predictive Personalized Decision Support (PEPPER) system provides personalized bolus advice for people with type 1 diabetes. The system incorporates an adaptive insulin recommender system (based on case-based reasoning, an artificial intelligence methodology), coupled with a safety system, which includes predictive glucose alerts and alarms, predictive low-glucose suspend, personalized carbohydrate recommendations, and dynamic bolus insulin constraint. We evaluated the safety and efficacy of the PEPPER system compared to a standard bolus calculator.
View Article and Find Full Text PDFSensors (Basel)
September 2020
(1) Background: People living with type 1 diabetes (T1D) require self-management to maintain blood glucose (BG) levels in a therapeutic range through the delivery of exogenous insulin. However, due to the various variability, uncertainty and complex glucose dynamics, optimizing the doses of insulin delivery to minimize the risk of hyperglycemia and hypoglycemia is still an open problem. (2) Methods: In this work, we propose a novel insulin bolus advisor which uses deep reinforcement learning (DRL) and continuous glucose monitoring to optimize insulin dosing at mealtime.
View Article and Find Full Text PDFIEEE J Biomed Health Inform
April 2021
People with Type 1 diabetes (T1D) require regular exogenous infusion of insulin to maintain their blood glucose concentration in a therapeutically adequate target range. Although the artificial pancreas and continuous glucose monitoring have been proven to be effective in achieving closed-loop control, significant challenges still remain due to the high complexity of glucose dynamics and limitations in the technology. In this work, we propose a novel deep reinforcement learning model for single-hormone (insulin) and dual-hormone (insulin and glucagon) delivery.
View Article and Find Full Text PDFJ Healthc Inform Res
September 2020
Diabetes is a chronic disease affecting 415 million people worldwide. People with type 1 diabetes mellitus (T1DM) need to self-administer insulin to maintain blood glucose (BG) levels in a normal range, which is usually a very challenging task. Developing a reliable glucose forecasting model would have a profound impact on diabetes management, since it could provide predictive glucose alarms or insulin suspension at low-glucose for hypoglycemia minimisation.
View Article and Find Full Text PDFBackground: A locally developed case-based reasoning (CBR) algorithm, designed to augment antimicrobial prescribing in secondary care was evaluated.
Methods: Prescribing recommendations made by a CBR algorithm were compared to decisions made by physicians in clinical practice. Comparisons were examined in 2 patient populations: first, in patients with confirmed Escherichia coli blood stream infections ("E.
Increasing use of continuous glucose monitoring (CGM) data has created an array of glucose metrics for glucose variability, temporal patterns, and times in ranges. However, a gold standard metric has not been defined. We assess the performance of multiple glucose metrics to determine their ability to detect intra- and interperson variability to determine a set of recommended metrics.
View Article and Find Full Text PDFSelf-monitored blood glucose (SMBG) and real-time continuous glucose monitoring (rtCGM) are used by people living with type 1 diabetes (T1D) to assess glucose and inform decision-making. Percentage time in range (%TIR) between 3.9 and 10 mmol/L has been associated with incident microvascular complications using historical SMBG data.
View Article and Find Full Text PDF