Publications by authors named "Patrick McGah"

Purpose: There has been interest in recent work in using computational fluid dynamics with Lagrangian analysis to calculate the trajectory of emboli-like particles in the vasculature. While previous studies have provided an understanding of the hemodynamic factors determining the fates of such particles and their relationship to risk of stroke, most analyses have relied on a particle equation of motion that assumes the particle is "small" e.g.

View Article and Find Full Text PDF

The current study evaluates quantitatively the impact that intermittent aortic valve (AV) opening has on the thrombogenicity in the aortic arch region for patients under left ventricular assist device (LVAD) therapy. The influence of flow through the AV, opening once every five cardiac cycles, on the flow patterns in the ascending aortic is measured in a patient-derived computed tomography image-based model, after LVAD implantation. The mechanical environment of flowing platelets is investigated, by statistical treatment of outliers in Lagrangian particle tracking, and thrombogenesis metrics (platelet residence times and activation state characterized by shear stress accumulation) are compared for the cases of closed AV versus intermittent AV opening.

View Article and Find Full Text PDF

This study quantifies thrombogenic potential (TP) of a wide range of left ventricular assist device (LVAD) outflow graft anastomosis angles through state-of-the-art techniques: 3D imaged-based patient-specific models created via virtual surgery and unsteady computational fluid dynamics with Lagrangian particle tracking. This study aims at clarifying the influence of a single parameter (outflow graft angle) on the thrombogenesis associated with flow patterns in the aortic root after LVAD implantation. This is an important and poorly-understood aspect of LVAD therapy, because several studies have shown strong inter and intrapatient thrombogenic variability and current LVAD implantation strategies do not incorporate outflow graft angle optimization.

View Article and Find Full Text PDF

Background: Computational modeling of intracranial aneurysms provides insights into the influence of hemodynamics on aneurysm growth, rupture, and treatment outcome. Standard modeling of coiled aneurysms simplifies the complex geometry of the coil mass into a homogeneous porous medium that fills the aneurysmal sac. We compare hemodynamics of coiled aneurysms modeled from high-resolution imaging with those from the same aneurysms modeled following the standard technique, in an effort to characterize sources of error from the simplified model.

View Article and Find Full Text PDF

Central venous catheters (CVCs), placed in the superior vena cava (SVC) for hemodialysis or chemotherapy, are routinely filled while not in use with heparin, an anticoagulant, to maintain patency and prevent thrombus formation at the catheter tip. The heparin-locking procedure, however, places the patient at risk for systemic bleeding, as heparin is known to leak from the catheter into the blood stream. We provide evidence from detailed in vitro experiments that shows the driving mechanism behind heparin leakage to be convective-diffusive transport due to the pulsatile flow surrounding the catheter.

View Article and Find Full Text PDF

This study reformulates Murray's well-known principle of minimum work as applied to the cardiovascular system to include the effects of the shear-thinning rheology of blood. The viscous behavior is described using the extended modified power law (EMPL), which is a time-independent, but shear-thinning rheological constitutive equation. The resulting minimization problem is solved numerically for typical parameter ranges.

View Article and Find Full Text PDF

Central venous catheters are often filled when not in use with an anticoagulating fluid, usually heparinized saline, known as the locking fluid. However, the use of the locking fluid is associated with known risks because of "leakage" of the lock. A new hypothesis is proposed here to explain the lock fluid leakage: that the leakage is due to advective and diffusive mass transfer by blood flow around the catheter tip in situ.

View Article and Find Full Text PDF

Computational hemodynamic simulations of cerebral aneurysms have traditionally relied on stereotypical boundary conditions (such as blood flow velocity and blood pressure) derived from published values as patient-specific measurements are unavailable or difficult to collect. However, controversy persists over the necessity of incorporating such patient-specific conditions into computational analyses. We perform simulations using both endovascularly-derived patient-specific and typical literature-derived inflow and outflow boundary conditions.

View Article and Find Full Text PDF

Arteriovenous fistulae are created surgically to provide adequate access for dialysis patients suffering from end-stage renal disease. It has long been hypothesized that the rapid blood vessel remodeling occurring after fistula creation is in part a process to restore the mechanical stresses to some preferred level, i.e.

View Article and Find Full Text PDF

Arteriovenous fistulae are surgically created to provide adequate access for dialysis patients suffering from end-stage renal disease. It has long been hypothesized that the rapid blood vessel remodeling occurring after fistula creation is, in part, a process to restore the mechanical stresses to some preferred level, i.e.

View Article and Find Full Text PDF

Objective: The mechanisms of restenosis in autogenous vein bypass grafts placed for peripheral artery disease are not completely understood. We investigated the role of hemodynamic stress in a case study of a revised bypass graft that failed due to restenosis.

Methods: The morphology of the lumen was reconstructed from a custom three-dimensional ultrasound system.

View Article and Find Full Text PDF

We report a study of the role of hemodynamic shear stress in the remodeling and failure of a peripheral artery bypass graft. Three separate scans of a femoral to popliteal above-knee bypass graft were taken over the course of a 16 month period following a revision of the graft. The morphology of the lumen is reconstructed from data obtained by a custom 3D ultrasound system.

View Article and Find Full Text PDF