Publications by authors named "Patrick Kessler"

Background: Evaluation of delivered dose to the dominant intraprostatic lesion (DIL) for moderately hypofractionated radiotherapy of prostate cancer by cone beam computed tomography (CBCT)-based dose accumulation and target coverage analysis.

Methods: Twenty-three patients with localized prostate cancer treated with moderately hypofractionated prostate radiotherapy with simultaneous integrated boost (SIB) between December 2016 and February 2020 were retrospectively analyzed. Included patients were required to have an identifiable DIL on bi-parametric planning magnetic resonance imaging (MRI).

View Article and Find Full Text PDF

Purpose: To compare radiotherapy plans between an O-ring and a conventional C-arm linac for hypofractionated high-dose prostate radiotherapy in terms of plan quality, dose distribution, and quality assurance in a multi-vendor environment.

Methods: Twenty prostate cancer treatment plans were irradiated on the O-ring Varian Halcyon linac and were re-optimized for the C-arm Elekta Synergy Agility linac. Dose-volume histogram metrics for target coverage and organ at risk dose, quality assurance, and monitor units were retrospectively compared.

View Article and Find Full Text PDF

For routine calibration of dosemeters used for environmental radiation monitoring, a low dose rate 137Cs gamma ray calibration field that fully satisfies the requirement of the ISO 4037 series was established in the Facility of Radiation Standards in Japan Atomic Energy Agency. Two different methods were employed to determine the reference air kerma rate, namely a conventional ionisation chamber and a G(E) function method used a newly developed scintillation spectrometer. To fulfil the requirement of the ISO 4037 and suppress scattering of Cs gamma ray within the room as far as possible, a suitable lead collimator was introduced to limit the irradiation area at test points and placed at the middle height in an irradiation room with a grating floor.

View Article and Find Full Text PDF

As a consequence of the Chernobyl nuclear power plant accident in 1986, all European countries have installed automatic dosimetry network stations as well as air sampling systems for the monitoring of airborne radioactivity. In Europe, at present, almost 5,000 stations measure dose rate values in nearly real time. In addition, a few hundred air samplers are operated.

View Article and Find Full Text PDF

A method of measuring the extent to which space curves encircle one another is introduced. The method provides a family of sets which characterize encircling curves, allowing curve pairs that engage (and also single curves that self-engage) to be distinguished. The method is applied to the backbone chains of protein molecules.

View Article and Find Full Text PDF