Purpose: A study was conducted using high-fidelity electronic health record (EHR)-based simulations with incorporated eye tracking to understand the workflow of critical care pharmacists within the EHR, with specific attention to the data elements most frequently viewed.
Methods: Eight critical care pharmacists were given 25 minutes to review 3 simulated intensive care unit (ICU) charts deployed in the simulation instance of the EHR. Using monitor-based eye trackers, time spent reviewing screens, clinical information accessed, and screens used to access specific information were reviewed and quantified to look for trends.