Background: Previous studies in mouse, and zebrafish embryos show strong expression in progenitor cells of neuronal and neural crest tissues suggesting its involvement in neural crest specification. However, the role of human transcription factor activator protein 2 ( in human embryonic central nervous system (CNS), orofacial and maxillofacial development is unknown.
Methods: Through a collaborative work, exome survey was performed in families with congenital CNS, orofacial and maxillofacial anomalies.
Background: Rasmussen's encephalitis (RE) is a rare neurologic disorder characterized by progressive seizures and unilateral cerebral atrophy with onset during childhood and unknown etiology. When medical therapy appears refractory, surgical disconnection of the affected hemisphere is indicated. Quality of life after functional hemispherectomy is largely good, affected females may therefore pursue pregnancy.
View Article and Find Full Text PDFRationale And Objectives: Aim of this study was to assess the impact of contrast media dose (CMD) reduction on diagnostic quality of photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT).
Methods: CT scans of the abdominal region with differing CMD acquired in portal venous phase on a PCD-CT were included and compared to EID-CT scans. Diagnostic quality and contrast intensity were rated.
Purpose: Due to a lack of data, there is an ongoing debate regarding the optimal frontline interventional therapy for unresectable hepatocellular carcinoma (HCC). The aim of the study is to compare the results of transarterial radioembolization (TARE) as the first-line therapy and as a subsequent therapy following prior transarterial chemoembolization (TACE) in these patients.
Methods: A total of 83 patients were evaluated, with 38 patients having undergone at least one TACE session prior to TARE [27 male; mean age 67.
Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (≥ 5 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT.
View Article and Find Full Text PDFAim of this study was to assess the impact of virtual monoenergetic images (VMI) in combination and comparison with iterative metal artifact reduction (IMAR) on hip prosthesis-associated artifacts in photon-counting detector CT (PCD-CT). Retrospectively, 33 scans with hip prosthesis-associated artifacts acquired during clinical routine on a PCD-CT between 08/2022 and 09/2022 were analyzed. VMI were reconstructed for 100-190 keV with and without IMAR, and compared to polychromatic images.
View Article and Find Full Text PDFBackground: Complication rates in percutaneous transhepatic biliary drainage (PTBD) are non-uniform and vary considerably. In addition, the impact of peri-procedural risk factors is under-investigated.
Purpose: To compare success and complication rates of PTBD in patients with and without accompanying technical risk factors.
Cardiovasc Intervent Radiol
August 2022
Purpose: To evaluate technical feasibility and safety of common endovascular visceral interventions using a vascular robotic platform through preclinical study.
Material And Methods: The CorPath GRX Robotic System (Corindus Inc, Waltham, Massachusetts) was tested in an anesthetized pig for its ability to navigate various commercially available devices in the abdominal vasculature and to perform routine endovascular visceral procedures. After manually placing a guiding catheter in the celiac trunk, several visceral branches were probed with microcatheters and -wires under robotic assistance, and embolization with liquids (lipiodol), detachable coils and plugs were performed.
We aimed to investigate the diagnostic utility of MRI extracellular volume fraction (ECV) for the assessment of liver cirrhosis severity as defined by Child-Pugh class. In this retrospective study, 90 patients (68 cirrhotic patients and 22 controls), who underwent multiparametric liver MRI, were identified. Hepatic T1 relaxation times and ECV were assessed.
View Article and Find Full Text PDFInvest Radiol
July 2022
Objective: Robust dynamic contrast-enhanced T1-weighted images are crucial for accurate detection and categorization of focal liver lesions in liver/abdominal magnetic resonance imaging (MRI). As optimal dynamic imaging usually requires multiple breath-holds, its inherent susceptibility to motion artifacts frequently results in degraded image quality in incompliant patients. Because free-breathing imaging may overcome this drawback, the intention of this study was to evaluate a dynamic MRI sequence acquired during free breathing using the variable density, elliptical centric golden angle radial stack-of-stars radial sampling scheme, which so far has not been implemented in 4-dimensional applications.
View Article and Find Full Text PDFBackground Cervical spine CT is regularly performed to exclude cervical spine injury during the initial evaluation of trauma patients. Patients with asymmetry of the lateral atlantodental interval (LADI) often undergo subsequent MRI to rule out ligamentous injuries. The clinical relevance of an asymmetric LADI and the benefit of additional MRI remain unclear.
View Article and Find Full Text PDFPurpose: Compressed sensing (CS) is a method to accelerate MRI acquisition by acquiring less data through undersampling of k-space. In this prospective study we aimed to evaluate whether a three-dimensional (3D) isotropic proton density-weighted fat saturated sequence (PDwFS) with CS can replace conventional multidirectional two-dimensional (2D) sequences at 1.5 Tesla.
View Article and Find Full Text PDFObjectives: To investigate the impact of aortic valve calcification and brain morphology on acute peri-procedural cerebrovascular events (CVEs) in patients undergoing transcatheter aortic valve implantation (TAVI).
Background: Aortic valve calcification and stenosis can be assessed with echocardiography. Cerebral magnetic resonance imaging (MRI) depicts and quantifies morphological signs of hypoperfusion and vascular embolism, which is of special interest in patients with severe aortic stenosis.
Objectives: To intraindividually compare gadoxetate disodium and gadofosveset trisodium regarding vessel contrast, image quality and vessel delineation in dynamic contrast-enhanced liver MRI at 3.0T.
Methods: Twelve patients underwent 3.
Objectives: Our aim was to retrospectively evaluate the occurrence of respiratory motion artefacts in patients undergoing dynamic liver magnetic resonance (MR) either with gadoxetate disodium or gadobutrol.
Methods: Two hundred and thirty liver MR studies (115 with gadobutrol, 115 with gadoxetate disodium) were analysed. Respiratory motion artefacts on dynamic 3D T1-weighted MR images (pre-contrast, arterial, venous, and late-dynamic phase) were assessed using a five-point rating scale.