J Chromatogr B Analyt Technol Biomed Life Sci
September 2020
Amino acids have been of great interest in clinical studies since variation in their concentration may provide information about different disorders. For the first time, a non-separative method based on single quadrupole mass spectrometry (qMS) for the simultaneous semiquantitative determination of sixteen amino acids in saliva samples has been developed. The method includes derivatisation of amino acids with ethyl chloroformate-pyridine-ethanol to obtain volatile products, liquid-liquid extraction (LLE) and further analysis using a programmed temperature vaporizer (PTV) coupled to qMS.
View Article and Find Full Text PDFTalanta
January 2019
We present the development and validation of a sensitive method for the reliable determination of sixteen polycyclic aromatic hydrocarbons (PAHs) in saliva samples, which can be used as exposure markers. This method was based on a liquid-liquid extraction and programmed temperature vaporizer-gas chromatography-mass spectrometry analysis (LLE-PTV-GC-MS). Since no matrix effect was found, quantification was performed using external calibration.
View Article and Find Full Text PDFIn this work, a method for the quantitative and qualitative analysis of 11 polycyclic aromatic hydrocarbons (PAHs) in urine samples is reported. The method is based on the coupling of a programmed temperature vaporizer (PTV) with a quadrupole mass spectrometer (qMS), via a deactivated fused silica tubing. Before the PTV-qMS analysis, the samples were subjected to a liquid-liquid extraction (LLE).
View Article and Find Full Text PDFIn this work, ten possible volatile biomarkers of lung cancer (acetone, 2-butanone, ethyl acetate, 2-pentanone, 4-methyl-2-pentanone, 2-hexanone, 3-heptanone, 2-heptanone, 3-octanone, and 2-nonanone) have been analyzed to evaluate their different concentration levels in urine samples from lung cancer patients (n = 12) and healthy controls (n = 12). The volatile compounds were generated with a headspace autosampler and analyzed with a gas chromatograph equipped with a programmed temperature vaporizer and mass spectrometry detector (HS-PTV-GC-MS). With the aim of evaluating the aforementioned differences, a Mann-Whitney U test and box-plots were obtained.
View Article and Find Full Text PDFEU legislation prohibits the use of certain azo dyes which, on reduction, form any of 22 aromatic amines listed in Regulation (EC) 1907/2006 at concentrations above the threshold limit of 30 mg Kg(-1). Two different extraction techniques for the determination of aromatic amines formed from azo dyes in textiles in combination with gas chromatography-mass spectrometry (GC-MS) are described. The first one is based on microextraction by packed sorbent (MEPS) and the other approach involves salting-out-assisted liquid-liquid extraction (SALLE).
View Article and Find Full Text PDF