Introduction: Emotion regulation refers to use of strategies to change or suppress a response to an affective experience and is an important component of an individual's subjective wellbeing. Difficulties properly regulating emotions are related to psychopathological processes.
Objective: This study assessed the factor structure of the Brazilian version of the Emotion Regulation Questionnaire (ERQ); the invariance of its psychometric parameters as a function of gender; and its convergent validity with other scales measuring affective processes.
Objectives: Variables affecting the performance of ultrasound-guided transthoracic needle biopsy (US-TTNB) are not well established. We examined clinical and imaging variables affecting the sensitivity and the complication rates of US-TTNB.
Methods: We retrospectively reviewed a consecutive series of 528 US-TTNBs performed from 2008 to 2017.
Background: Current lung cancer screening guidelines use mean diameter, volume or density of the largest lung nodule in the prior computed tomography (CT) or appearance of new nodule to determine the timing of the next CT. We aimed at developing a more accurate screening protocol by estimating the 3-year lung cancer risk after two screening CTs using deep machine learning (ML) of radiologist CT reading and other universally available clinical information.
Methods: A deep machine learning (ML) algorithm was developed from 25,097 participants who had received at least two CT screenings up to two years apart in the National Lung Screening Trial.
Background: Transcarotid transcatheter aortic valve replacement (TAVR) recipients may be exposed to a higher ipsilateral subclinical cerebral ischemic burden compared with the contralateral hemisphere. We sought (1) to compare the cerebral ischemic burden of the 2 hemispheres after transcarotid TAVR, as evaluated by diffusion weighted-magnetic resonance imaging (DW-MRI), and (2) to identify the factors associated with ipsilateral ischemic burden.
Methods: This prospective study included 52 patients undergoing transcarotid TAVR, followed by a DW-MRI examination.
Objectives: We sought to evaluate the position of balloon-expandable valves in relation to the coronary ostia using an angiographic- and computed tomography (CT)-based analysis, and to determine the impact of valve position on coronary angiography (CA)/percutaneous coronary intervention (PCI) feasibility and results.
Methods: A total of 533 patients who received a Sapien XT or Sapien 3 valve were included in the angiographic analysis. Of these, 49 benefited from an opportunistic electrocardiography-gated CT after transcatheter aortic valve replacement (TAVR) and were included in the CT analysis.
Introduction And Objectives: We assessed the long-term hemodynamic performance of transcatheter heart valve (THV) by paired transthoracic echocardiography (TTE), and the incidence, characteristics and factors associated with THV structural valve degeneration (SVD).
Methods: A total of 212 patients who underwent transcatheter aortic valve replacement and had a potential follow-up >5 years with at least 1 TTE ≥ 1-year postprocedure were included. All patients had a TTE at 1 to 5 years and 36 had another one at 6 to 10 years.
During the last few years, burnout has gained more and more attention for its strong connection with job performance, absenteeism, and presenteeism. It is a psychological phenomenon that depends on occupation, also presenting differences between sexes. However, to properly compare the burnout levels of different groups, a psychometric instrument with adequate validity evidence should be selected (i.
View Article and Find Full Text PDFObjective: In lung cancer screening practice low-dose computed tomography, diameter, and volumetric measurement have been used in the management of screen-detected lung nodules. The aim of this study was to compare the performance of nodule malignancy risk prediction tools using diameter or volume and between computer-aided detection (CAD) and radiologist measurements.
Methods: Multivariable logistic regression models were prepared by using data from two multicenter lung cancer screening trials.
Span J Psychol
October 2018
The investigation of personality using the Rorschach Method has been historically established, however, its proper use requires continuous study, especially in regard to reliability, validity and normative references. This study's objective was to verify stability indicators of Rorschach (French Approach) through a reassessment (after 15 years) of non-patient adults previously addressed in the normative study by Pasian (1998). A total of 88 adults, aged between 34 and 69 years old, of both sexes, with different socio-economic and educational levels, were reassessed in 2013 in the state of São Paulo, Brazil.
View Article and Find Full Text PDFDespite the growing evidence with emerging transcatheter tricuspid valve repair therapies, the experience with transcatheter tricuspid valve replacement remains sparse. We describe a case of severe tricuspid regurgitation in a 79-year-old patient deemed unsuitable for isolated tricuspid valve surgery, successfully treated with a 40-mm self-expandable NaviGate (NaviGate Cardiac Structures, Inc, Lake Forest, CA) valved stent via a transatrial approach, with excellent result and hemodynamic performance at 4 months.
View Article and Find Full Text PDFThe aim of this paper is to present a revision of international versions of the Utrecht Work Engagement Scale and to describe the psychometric properties of a Portuguese version of the UWES-9 developed simultaneously for Brazil and Portugal, the validity evidence related with the internal structure, namely, Dimensionality, measurement invariance between Brazil and Portugal, and Reliability of the scores. This is the first UWES version developed simultaneously for both countries, and it is an important instrument for understanding employees' work engagement in the organizations, allowing human resources departments to better use workforces, especially when they are migrants. A total of 524 Brazilian workers and 522 Portuguese workers participated in the study.
View Article and Find Full Text PDFLeft atrial appendage aneurysm (LAAA) is a rare entity. Clinical manifestations include arrhythmias and systemic embolization. We show here an example of a large and ectopic LAAA mimicking a mediastinal mass on chest X-ray and presenting with incessant atrial arrhythmias.
View Article and Find Full Text PDFInteract Cardiovasc Thorac Surg
March 2018
Transcatheter valve-in-valve implantation within dysfunctional surgical bioprosthesis has become an alternative to redo open-heart surgery. However, suitability for valve-in-valve implantation in the tricuspid position is often limited by large surgical valve sizes. We report a case of a transcatheter tricuspid valve-in-valve implantation with a 29-mm balloon-expandable prosthesis within a 33-mm failed bioprosthesis (exceeding manufacturer's sizing recommendations).
View Article and Find Full Text PDFBackground: Results from retrospective studies indicate that selecting individuals for low-dose CT lung cancer screening on the basis of a highly predictive risk model is superior to using criteria similar to those used in the National Lung Screening Trial (NLST; age, pack-year, and smoking quit-time). We designed the Pan-Canadian Early Detection of Lung Cancer (PanCan) study to assess the efficacy of a risk prediction model to select candidates for lung cancer screening, with the aim of determining whether this approach could better detect patients with early, potentially curable, lung cancer.
Methods: We did this single-arm, prospective study in eight centres across Canada.
Background: Residual aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR) is associated with greater mortality; yet, determining AR severity post-TAVR using Doppler echocardiography remains challenging. Cardiovascular magnetic resonance (CMR) is purported as a more accurate means of quantifying AR; however, no data exist regarding the prognostic value of AR as assessed by CMR post-TAVR.
Objectives: This study sought to evaluate the effect of AR assessed with CMR on clinical outcomes post-TAVR.
Objectives: To implement a cost-effective low-dose computed tomography (LDCT) lung cancer screening program at the population level, accurate and efficient interpretation of a large volume of LDCT scans is needed. The objective of this study was to evaluate a workflow strategy to identify abnormal LDCT scans in which a technician assisted by computer vision (CV) software acts as a first reader with the aim to improve speed, consistency, and quality of scan interpretation.
Methods: Without knowledge of the diagnosis, a technician reviewed 828 randomly batched scans (136 with lung cancers, 556 with benign nodules, and 136 without nodules) from the baseline Pan-Canadian Early Detection of Lung Cancer Study that had been annotated by the CV software CIRRUS Lung Screening (Diagnostic Image Analysis Group, Nijmegen, The Netherlands).
Introduction And Objectives: The self-expanding Portico valve is a new transcatheter aortic valve system yielding promising preliminary results, yet there are no comparative data against earlier generation transcatheter aortic valve systems. The aim of this study was to compare the hemodynamic performance of the Portico and balloon-expandable SAPIEN XT valves in a case-matched study with echocardiographic core laboratory analysis.
Methods: Twenty-two patients underwent transcatheter aortic valve implantation with the Portico 23-mm valve and were matched for aortic annulus area and mean diameter measured by multidetector computed tomography, left ventricular ejection fraction, body surface area, and body mass index with 40 patients treated with the 23-mm SAPIEN XT.
Transcatheter mitral valve-in-valve and valve-in-ring procedures have emerged as a potential alternative for patients with failed mitral bioprosthesis or mitral valve repair who are at very high or prohibitive surgical risk. However, transcatheter mitral valve-in-ring implantation (TMViRI) remains a challenging procedure, partially because of the oval shape of mitral rings, which may lead to prosthesis dysfunction when the ring is not able to adopt the circular shape of the transcatheter valve. We present a case of failed TMViRI in a dysfunctional mitral homograft.
View Article and Find Full Text PDFPlasma pro-surfactant protein B (pro-SFTPB) levels have recently been shown to predict the development of lung cancer in current and ex-smokers, but the ability of pro-SFTPB to predict measures of chronic obstructive pulmonary disease (COPD) severity is unknown. We evaluated the performance characteristics of pro-SFTPB as a biomarker of lung function decline in a population of current and ex-smokers. Plasma pro-SFTPB levels were measured in 2503 current and ex-smokers enrolled in the Pan-Canadian Early Detection of Lung Cancer Study.
View Article and Find Full Text PDFIncreased myocardial trabeculations define noncompaction cardiomyopathy (NCC). Imaging advancements have led to increasingly common identification of prominent trabeculations with unknown implications. We quantified and determined the impact of trabeculations' burden on cardiac function and stretch in a population of healthy young adults.
View Article and Find Full Text PDF