Objective: The aim of this study was to evaluate the mechanical properties of dental resins and dental nanocomposites by means of 3-point bending, 4-point bending and piston-on-three ball biaxial static tests and also to investigate their dynamic mechanical properties. The obtained results from the static 3-point bending test also were compared with the corresponding mode in DMTA.
Methods: The hydrophilic surface of the inorganic OX-50 particles was treated with γ-MPS and the resulting silanized OX-50 was characterized using FTIR and TGA.