Background: The SAFIR prototype insert is a preclinical Positron Emission Tomography (PET) scanner built to acquire dynamic images simultaneously with a 7 T Bruker Magnetic Resonance Imaging (MRI) scanner. The insert is designed to perform with an excellent coincidence resolving time of 194 ps Full Width Half Maximum (FWHM) and an energy resolution of 13.8% FWHM.
View Article and Find Full Text PDF(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7T Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500MBq, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of 54.
View Article and Find Full Text PDFBackground: Software for Tomographic Image Reconstruction (STIR) is an open-source library for PET and SPECT image reconstruction, implementing iterative reconstruction as well as 2D- and 3D-filtered back projection. Quantitative reconstruction of PET data requires the knowledge of the scanner geometry. Typical scanners, clinical as well as pre-clinical ones, use a block-type geometry.
View Article and Find Full Text PDFPurpose: The aim of this study is to introduce a fully automatic and reproducible short echo-time (STE) magnetic resonance imaging (MRI) segmentation approach for MR-based attenuation correction of positron emission tomography (PET) data in head region.
Procedures: Single STE-MR imaging was followed by generating attenuation correction maps (μ-maps) through exploiting an automated clustering-based level-set segmentation approach to classify head images into three regions of cortical bone, air, and soft tissue. Quantitative assessment was performed by comparing the STE-derived region classes with the corresponding regions extracted from X-ray computed tomography (CT) images.
Mol Imaging Biol
December 2015
Purpose: The aim of this study is to generate a four-class magnetic resonance imaging (MRI)-based attenuation map (μ-map) for attenuation correction of positron emission tomography (PET) data of the head area using a novel combination of short echo time (STE)/Dixon-MRI and a dedicated image segmentation method.
Procedures: MR images of the head area were acquired using STE and two-point Dixon sequences. μ-maps were derived from MRI images based on a fuzzy C-means (FCM) clustering method along with morphologic operations.