Publications by authors named "Parinaz Mehnati"

Introduction: Many researchers have suggested that bismuth composite shields (BCS) reduce breast dose remarkably; however, the level of this reduction and its impact on image quality has not been assessed. This study aimed to evaluate the efficiency of nano- and micro- BCS in reducing the dose and image quality during chest computed tomography (CT) scans.

Materials And Methods: Bismuth shields composed of 15 weighting percentage (wt%) and 20 wt% bismuth oxide (BiO) nano- and micro-particles mixed in silicon rubber polymer were constructed in 1 and 1.

View Article and Find Full Text PDF

Lead-free polymer composite shields are used in diagnostic radiology to protect patients from unnecessary radiation exposure. This study aimed to examine and introduce the radiation-shielding properties of single- and multi-metal nanoparticle (NP)-based composites containing Bi, W, and Sn using Geant4, MCNPX, and XCom for radiological applications. The mass attenuation coefficients and effective atomic numbers of single- and multi-metal NP-loaded polymer composites were calculated using the Geant4 and MCNPX simulation codes for X-ray energies of 20-140 keV.

View Article and Find Full Text PDF

Background: Nowadays, there has been a growing demand for low-dose computed tomography (LDCT) protocols. CT has a critical role in the management of the diagnosis chain of pulmonary disease, especially in lung cancer screening. There have been introduced several dose reduction methods, however, most of them are time-consuming, intricate, and vendor-based strategies that are hardly used in clinics routinely.

View Article and Find Full Text PDF

Background: Radiotherapy plays an important role in the treatment of breast cancer. In the process of radiotherapy, the underling lung tissue receives higher doses from treatment field, which led to incidence of radiation pneumonitis.

Objective: The present study aims to evaluate the predictive factors of radiation pneumonitis and related changes in pulmonary function after 3D-conformal radiotherapy of breast cancer.

View Article and Find Full Text PDF

Introduction: There are various radioprotective agents with different mechanisms that help to decrease ionizing radiation side effects. The radioprotective effect of Cimetidine and IMOD was assessed individually and compared with the hybrid radioprotectors agents (HRPAs-IMOD and Cimetidine) on human lymphocyte cells.

Methods: Twenty healthy volunteers (ten men and ten women) participated in the present study.

View Article and Find Full Text PDF

Diabetes, which is considered as a chronic metabolic disorder leads to an increase in inflammatory cytokines and oxidative stresses. Studies have shown several functional differences in the oxidative stress and inflammatory cytokines responses in diabetic/normal cancerous patients candidate for radiotherapy. Also, radiotherapy as a cancer treatment modality is known as a carcinogen due to oxidative damage via generation of reactive oxygen metabolites and also causing inflammation of the tissue by increasing the inflammatory cytokines.

View Article and Find Full Text PDF

Recent studies have shown that the particle size of the shielding material and photon energy has significant effects on the efficiency of radiation-shielding materials. The purpose of the current study was to investigate the shielding properties of the bismuth-silicon (Bi-Si) composite containing varying percentages of micro- and nano-sized Bi particles for low-energy X-rays. Radiation composite shields composed of nano- and micro-sized Bi particles in Si-based matrix were constructed.

View Article and Find Full Text PDF

Background: The collimator scatter factor (S) is one of the most important parameters in monitor unit (MU) calculation. There are several factors that impact S values, including head structures, backscatter in dose monitoring chambers, and wedges. The objective of this study was to investigate the variation of S with different buildup cap materials, wall thickness of buildup caps, source-to-chamber distances (SCDs), ionization chambers, and wedge angles in 6 MV photon beam.

View Article and Find Full Text PDF

The study aimed to assess the effect of bismuth (Bi) shielding on dose reduction and image quality in computed tomography (CT) through a literature review. A search was conducted in the following databases: Web of Science, PubMed, Google Scholar, and Scopus. Studies that reported estimated dose reduction with bismuth shielding during imaging of the eye, thyroid, and breast were included, and a meta-regression analysis was used to examine the influence of the CT scanner type on the dose reduction.

View Article and Find Full Text PDF

The article aims at constructing protective composite shields for breasts in chest computed tomography and investigating the effects of applying these new bismuth composites on dose and image quality. Polyurethane and silicon with 5% of bismuth were fabricated as a protective shield. At first, their efficiency in attenuating the X-ray beam was investigated by calculating the total attenuation coefficients at diagnostic energy range.

View Article and Find Full Text PDF

Near-infrared (NIR) optical imaging is a non-ionizing modality that is emerging as a diagnostic/prognostic tool for breast cancer according to NIR differentiation of hemoglobin (Hb) concentration. The transmission values of LED-sourced light at 625 nm were measured by power meter to evaluate the optical properties of Hb in breast phantom containing major and minor vessels. For the simulation of blood variations in cancerous breast condition, we prepared 2 concentrations of pre-menopausal Hb and 4 concentrations of post-menopausal Hb and, for comparison with normal tissue, one concentration of Hb injected inside the phantom's vessels.

View Article and Find Full Text PDF

Purpose: The biological effects of ionizing radiation (BEIR VII) report estimates that the risk of getting cancer from radiation is increased by about a third from current regulation risk levels. The propose of this study was to estimate cancer induction risk from abdominopelvic computed tomography (CT) scanning of adult patients using 6- and 16-slice CT scanners.

Materials And Methods: A cross-sectional study on 200 patients with abdominopelvic CT scan in 6- and 16-slice scanners was conducted.

View Article and Find Full Text PDF

Background: Blood concentrations and oxygen saturation levels are important biomarkers for breast cancer diagnosis.

Objectives: In this study, the absorption coefficient of hemoglobin (Hb) was used to distinguish between normal and abnormal breast tissue.

Materials And Methods: A near-infrared source (637 nm) was transmitted from major and minor vessels of a breast phantom containing 2×, 4× concentrations of oxy- and deoxy-Hb.

View Article and Find Full Text PDF

Background: Mammographic density determined according paranchymal patterns is a risk factor for breast cancer and its relationships with body and other breast characteristics of women is important. The purpose of the present study was to correlate breast parenchymal patterns and mammography abnormality findings with women's BMI, compressed breast thickness (CBT) and age in Tabriz city, Iran.

Materials And Methods: From 1,100 mammograms interpreted by radiologists, breast parenchymal was classified into four categories from Types 1 (mostly fatty) through 4 (mostly fibroglandular tissue).

View Article and Find Full Text PDF

Sensitivity and specificity are the two most important indicators in selection of medical imaging devices for cancer screening. Breast images taken by conventional or digital mammography, ultrasound, MRI and optical mammography were collected from 2,143,852 patients. They were then studied and compared for sensitivity and specificity results.

View Article and Find Full Text PDF

This study was aimed at evaluating the mean glandular dose (MGD) and affecting factors during mammography examinations by a full-field digital mammography unit. An extensive quality control program was performed to assure that the unit is properly working. Required information including compressed breast thickness (CBT), breast parenchymal pattern and technical factors used for imaging were recorded.

View Article and Find Full Text PDF

The aim of the current study was to investigate the effect of cardiologists' experience on the patient received dose during coronary angiography. The exposure parameters including fluoroscopy time, total kerma-area product (KAP), total air-kerma, fluoroscopy and cine acquisition KAP and air-kerma for five senior cardiologists with the experience of 6-10 y were recorded. The range of values for fluoroscopy time and total KAP were 2.

View Article and Find Full Text PDF

The purpose of this investigation was to measure the patient and staff dose during routine interventional cardiology procedures for an image intensifier-based and a flat detector system using a water phantom. The Integris BH3000 image intensifier-based (Philips) and the Axiom Artis flat detector-based (Siemens) angiography units were used in this study. The accuracy of tubes potential and irradiation timers and also internal dosimeters were verified and confirmed.

View Article and Find Full Text PDF

The electrical impedance of the human urinary bladder in both benign and malignant areas can be measured using an electrical impedance spectroscopy system (EIS). Glycine is usually used in the bladder surgery in the theatre to make an insulation medium for electro-surgery and the extension of the mucosa. In addition, a saline solution is usually used to wash the inside of the bladder after bladder surgery and it is used to extend the bladder tissue mucosa.

View Article and Find Full Text PDF

Purpose: The dosimetric features of an unflattened 6-MV photon beam of an Elekta SL-25 linac was calculated by the Monte Carlo (MC) method.

Material And Methods: The head of the Elekta SL-25 linac was simulated using the MCNP4C MC code. The accuracy of the model was evaluated using measured dosimetric features, including depth dose values and dose profiles in a water phantom.

View Article and Find Full Text PDF

The reason why RBE for cell killing fell to less than unity (1.0) with very high-LET heavy-ions ((40)Ar: 1,640 keV/microm; (56)Fe: 780, 1,200, 2,000 keV/microm) was explored by evaluating the fraction of non-hit cell (time-lapse observation) and cells undergoing interphase death (calculation based on our previous data). CHO cells were exposed to 4 Gy (30% survival dose) of Ar (1,640 keV/microm) or Fe-ions (2,000 keV/microm).

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessiona1qmnaupikhu1d1taiue0hlp66a3tulf): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once