Background: Catheter-delivered radiofrequency (RF) lesion formation is a complex phenomenon, and few studies have explored the effect of catheter orientation on lesion size and catheter orientation behavior during pulmonary vein isolation (PVI) procedures. We evaluated the influence of catheter orientation on lesion dimensions in an in vitro experimental setting and investigated the catheter orientation behavior during PVI.
Methods And Results: 72 lesions were created in vitro on a porcine heart using a contact force catheter in a parallel, oblique, and perpendicular tip to tissue orientation.
Objectives: In an in vitro model, the authors tested the hypotheses that: 1) lesion dimensions correlate with lesion size index (LSI); and 2) LSI could predict lesion dimensions better than power, contact force (CF), and force-time integral (FTI).
Background: When performing radiofrequency (RF) catheter ablation for cardiac arrhythmias, reliable predictors of lesion quality are lacking. The LSI is a multiparametric index incorporating time, power, CF, and impedance recorded during ablation.
When performing epicardial ablation of ventricular tachycardia (VT), caution must be taken not to damage the coronary arteries. We report a case in which a new, nonfluoroscopic technique for incorporating an accurate, real-time reconstruction of the main coronary vessels into a three-dimensional electroanatomic map was used for epicardial VT ablation.
View Article and Find Full Text PDFIntroduction: Not all candidates for cardiac resynchronization therapy (CRT) are responders at follow-up. Echocardiographic parameters of dyssynchrony do not predict the response. Analysis of electrical properties of left ventricle (LV) by noncontact mapping (NCM) could be useful to better identify candidates for CRT.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
August 2009
Introduction: Pulmonary veins isolation usually requires a multielectrode catheter for mapping in addition to the ablation catheter. We describe our experience with a new multipolar catheter designed for simultaneous mapping and ablation (MESH, Bard).
Methods And Results: We tested the catheter in 15 patients (mean age 61.
Objective: To obtain a quantitative estimate of the overall costs and cost effectiveness ratio of sirolimus-eluting stents (SES) implantation and tirofiban infusion compared to abciximab and bare metal stent (BMS) in patients undergoing primary intervention for acute ST segment elevation myocardial infarction (STEMI).
Methods: In the attempt to make the unrestricted use of SES in STEMI patients affordable under the current European reimbursement system, between March 6, 2003, and April 23, 2004, 175 patients with STEMI were randomized to receive tirofiban infusion and SES versus abciximab and BMS as part of the STRATEGY trial. Costs and outcome were monitored for 2 years.
Unlabelled: Cardiovascular disease is a major public health problem. Rapid and accurate diagnosis in the emergency department is essential for timely initiation of treatment, thus any means for improving the speed and accuracy of acute coronary syndrome (ACS) diagnosis can contribute to better clinical and economic outcomes. Measurement of circulating level of troponin has proven to be a sensitive and specific test for cardiac damage detection but they do not discriminate between ischemic and not ischemic etiologies of myocardial injury.
View Article and Find Full Text PDFThis paper reports the rationale for the cardiovascular protective effects of angiotensin-converting enzyme (ACE) inhibitors and reviews the overall results of recent randomized clinical trials. ACE-inhibitors prevent degradation of bradykinin, exert anti-ischemic action, inhibit thrombosis and platelet aggregation, are antiatherogenic, improve endothelial function and vessel remodeling, and have anti-inflammatory properties. Previous trials have shown that ACE-inhibitors reduce cardiovascular events in patients with heart failure or ventricular dysfunction.
View Article and Find Full Text PDF