Int J Periodontics Restorative Dent
July 2022
This study clinically and histologically evaluated the performance of implants with different crestal morphologies: tissue-level implants and bone-level implants. Nine patients received at least two adjacent implants in an edentulous area: one bone-level implant (EO) and one tissue-level implant (TG) (total: 23 implants), placed beside each other using a single-stage delayed loading protocol. The implants were rehabilitated with screw-retained fixed partial dentures.
View Article and Find Full Text PDFBackground: Ultrasonic devices have a lot of dental application specially in hygiene and surgery. However there are some disadvantages like cut slowness and heat production. Prosthodontics application is less investigated.
View Article and Find Full Text PDFBackground: Replacement of missing teeth in the anterior aesthetic zone has challenged clinicians with fixed, removable or implant prosthodontics. Problems have been encountered could void aesthetic and functional results. The aim of this study was to present a clinical case report in which clinician challenged a very strong aesthetic case with an innovative surgical and prosthetic approach.
View Article and Find Full Text PDFBackground: The purpose of this study was to analyze pulpal temperature increase generated by prosthodontic margin repositioning and finishing with ultrasonic and rotating instruments. The temperature changes recorded were also correlated with the residual dentin thickness.
Methods: A sample of 32 human extracted molars was selected.
Int J Periodontics Restorative Dent
October 2019
The aim of the present report was to evaluate the clinical outcomes of edentulous jaws rehabilitated with the Brånemark Novum protocol over a 16-year period. Between April and November 2001, four patients (three males, one female) were rehabilitated with fixed full-arch rehabilitations supported by three immediately loaded implants following the Brånemark Novum protocol. Cumulative survival rates (CSRs) of the implants and prosthesis, bleeding on probing (BOP), Plaque Index (PI), probing depth (PD), implant stability quotient (ISQ; as measured through resonance frequency analysis [RFA]), and peri-implant bone resorption were evaluated over time, up to the 16-year follow-up.
View Article and Find Full Text PDFObjectives: To compare the cleaning efficacy of glycine air polishing against two different professional oral hygiene techniques on implants supporting full-arch fixed prostheses.
Method And Materials: Thirty patients with a total of 32 implant fixed full-arch rehabilitations in the maxilla and/or mandible (134 implants) were included. After the removal of the screw-retained prostheses, baseline peri-implant spontaneous bleeding (SB), Plaque Index (PI), probing depth (PD), and bleeding on probing (BOP) were recorded (T0).
The aim of the present study is to evaluate the expression of microRNA (miRNA) in peri-implant soft tissue and to correlate epigenetic information with the clinical outcomes of the implants up to the five-year follow-up. Seven patients have been rehabilitated with fixed screw-retained bridges each supported by implants. Peri-implant bone resorption and soft tissue health parameters have been recorded over time with a five-year follow-up.
View Article and Find Full Text PDFPurpose: To compare clinical outcomes of immediate vs delayed implant loading in edentulous maxillae with full-arch fixed prostheses.
Materials And Methods: Two patient groups were identified for this study: (1) the test group (TG), which included 34 patients (19 women, 15 men; mean age 56.7 years) treated with the Columbus Bridge Protocol with 4 to 6 postextractive implants loaded within 24 hours (163 implants total); and (2) the control group (CG), which included 15 patients (6 women, 9 men; mean age 59.
Purpose: To evaluate plaque accumulation, peri-implant soft tissue inflammation, and bone resorption in patients with immediately loaded implants supporting fixed full-arch prostheses.
Materials And Methods: A convenience sample of 72 patients treated with fixed full-arch prostheses supported by four to six immediately loaded implants was selected. Bleeding on probing (BOP), Plaque Index (PI), and peri-implant bone loss were measured.
Objectives: The objective of this study was to evaluate the accuracy of different impression techniques on multiple implants.
Material And Methods: A master cast simulating a jaw with four implants was used. Eight impression techniques were tested: open tray-polyether#1, open tray plus splint of impression copings with acrylic resin-polyether#1, closed tray-polyether#1, open tray-polyether#2, open tray-splint-polyether#2, closed tray-polyether#2, open tray-impression plaster, and digital impression (DI).
Int J Prosthodont
December 2017
Purpose: This paper describes a new ultrasonic instrument (tipholder DB1 with crown prep tip inserts) designed to optimize prosthodontic margin repositioning and finishing.
Materials And Methods: The insert movement was assessed, and it was demonstrated that tipholder DB1 provides its inserts with an elliptical-like movement, making the entire insert surface able to cut. Then, 20 extracted teeth were prepared using tipholder DB1, sonic instruments, and traditional drills.
Mater Sci Eng C Mater Biol Appl
January 2017
Objectives: The aim of the present study was to investigate the biocompatibility and mechanical characteristics of dental implant frameworks made of carbon fiber composite.
Methods: The biocompatibility of intact samples and fragments was evaluated by cell count and MTT test according to EN-ISO 10993-5:2009 directions. Destructive and non-destructive mechanical tests were performed in order to evaluate: porosity, static and dynamic elastic modulus of carbon fiber samples.
Purpose: The aim of this study was to analyze through a three-dimensional finite element analysis (3D-FEA) stress distribution on four implants supporting a full-arch implant-supported fixed prosthesis (FFP) using different prosthesis designs.
Materials And Methods: A 3D edentulous maxillary model was created and four implants were virtually placed into the maxilla and splinted, simulating an FFP without framework, with a cast metal framework, and with a carbon fiber framework. An occlusal load of 150 N was applied, stresses were transmitted into peri-implant bone, and prosthodontic components were recorded.
Purpose: The aim of this study was to evaluate the behavior of hard and soft tissue around implants with different surface treatments.
Materials And Methods: Eight patients were identified for this study. Each patient received at least 2 implants (1 control, 1 test) into an edentulous quadrant, for a total of 10 pairs of implants.
Statement Of Problem: The recent literature underlines a correlation between plaque and the development of periimplantitis but neglects the importance of the prosthetic factors.
Purpose: The purpose of this systematic review was to appraise the available literature to evaluate the role played by cement excess and misfitting components on the development of periimplantitis.
Material And Methods: An electronic search restricted to the English language was performed in PubMed, Embase, and the Cochrane Register up to September 1, 2014, based on a selected search algorithm.
Several factors contribute to distortion of implant prostheses during fabrication and could prevent passive, accurate adaptation between implants and implant frameworks. The misfit between implants and restorative components may be significant and possibly lead to biologic or mechanical complications. The aim of this article is to describe a laboratory luting technique used to lute implant cylinders to metal frameworks in implant prostheses.
View Article and Find Full Text PDFObjectives: This in vitro study investigated possible morphological and chemical changes induced by glycine or sodium bicarbonate powder air polishing on machined and acid-etched titanium surfaces.
Materials And Methods: The glycine powder (granulometry <65 μm) and sodium bicarbonate powder (granulometry <150 μm) were applied on 2 machined healing abutments and on 2 acid-etched healing abutments. The samples were characterized by scanning electron microscopy coupled with energy dispersive x-ray spectroscopy.
Purpose: This in vitro study evaluated the adhesive strength of a technique to lute implant cylinders to metal frameworks in implant-supported prostheses and ensure a good passive fit.
Materials And Methods: Different height samples were tested: In group 1, implant cylinders were 5 mm long; in group 2, they were 10 mm long. A universal testing machine (Instron) was used to perform pullout tests.
Objectives: Short-term results indicated that the Brånemark Novum protocol (Nobel Biocare AB, Goteborg, Sweden) allowed successful rehabilitation of mandibular edentulism with immediately loaded implants. Yet, long-term studies are lacking. The aim of the present retrospective study was to report the 11-year outcomes for patients treated according to this protocol.
View Article and Find Full Text PDFInt J Prosthodont
December 2014
Int J Periodontics Restorative Dent
August 2016
This prospective study reports the 6-year outcomes for patients rehabilitated with an immediate loading protocol of the maxilla (Columbus Bridge Protocol). In this study, 164 implants were inserted in 37 patients and loaded within 24 to 36 hours. Four implants failed during the first 6 months.
View Article and Find Full Text PDFPurpose: This study compared the surgical protocol efficacy of immediate and delayed implant loading in edentulous maxillae opposed by natural or restored mandibular dentitions over an observational period of 6 years or longer. The selected outcome determinants included individual implant survival data, progressive measurements of peri-implant bone resorption, prosthodontic survival and success data, and report of complications.
Materials And Methods: A convenience sample of 49 patients requiring fixed implant-supported maxillary prostheses was split into two groups.
Purpose: This systematic review considers possible etiologic factors and definitions of peri-implantitis as reported in the recent literature.
Materials And Methods: An electronic search of databases plus a hand search of the most relevant journals published between January 2005 and September 2012 were performed.
Results: The electronic and manual searches yielded 640 and 14 titles, respectively.
Purpose: To measure the vertical occlusal forces transmitted through crowns made of different restorative materials onto simulated peri-implant bone.
Materials And Methods: The study was conducted using a masticatory robot that is able to reproduce the mandibular movements and forces exerted during mastication. During robot mastication, the forces transmitted onto the simulated peri-implant bone were recorded using nine different restorative materials for the simulated single crown: zirconia, two glass-ceramics, a gold alloy, three composite resins, and two acrylic resins.
Objectives: The aim of this study was an in vitro comparison of osteoblast adhesion, proliferation and differentiation related to six dental implants with different surface characteristics, and to determine if the interaction between cells and implant is influenced by surface structure and chemical composition.
Material And Methods: Six types of implants were tested, presenting four different surface treatments: turned, sandblasted, acid-etched, anodized. The implant macro- and microstructure were analyzed using SEM, and the surface chemical composition was investigated using energy-dispersive X-ray analysis.