are among the most frequent bacteria known to cause biofilm-related infections. Pathogenic biofilms represent a global healthcare challenge due to their high tolerance to antimicrobials. In this study, water soluble polyethylene glycol (PEG)-coated gold nanospheres (28 ppm) and nanostars (15 ppm) with electrostatically adsorbed photosensitizer (PS) Toluidine Blue O (TBO) ∼4 μM were successfully synthesized and characterized as PEG-GNPs@TBO and PEG-GNSs@TBO.
View Article and Find Full Text PDFIndocyanine green (ICG) is a safe dye widely used in the biomedical field. Its photodynamic effect (PDT), originating from laser irradiation at 803 nm, opens interesting perspectives in theranostic applications. To overcome its low water stability, ICG can be shielded with nanoparticles (NPs).
View Article and Find Full Text PDFOptical tweezers have attracted significant attention for microrheological applications, due to the possibility of investigating viscoelastic properties in vivo which are strongly related to the health status and development of biological specimens. In order to use optical tweezers as a microrheological tool, an exact force calibration in the complex system under investigation is required. One of the most promising techniques for optical tweezers calibration in a viscoelastic medium is the so-called active-passive calibration, which allows determining both the trap stiffness and microrheological properties of the medium with the least a-priori knowledge in comparison to the other methods.
View Article and Find Full Text PDFYield stress materials deform as elastic solids or flow as viscous liquids, depending on the applied stress, which also allows them to trap particles below a certain size or density threshold. To investigate the conditions for such a transition at the microscale, we use an optofluidic microrheometer, based on the scattering of an infrared beam onto a microbead, which reaches forces in the nN scale. We perform creep experiments on a model soft material composed of swollen microgels, determining the limits of linear response and yield stress values, and observe quantitative agreement with bulk measurements.
View Article and Find Full Text PDFWe propose and demonstrate an on-chip optofluidic device allowing active oscillatory microrheological measurements with sub-μL sample volume, low cost and high flexibility. Thanks to the use of this optofluidic microrheometer it is possible to measure the viscoelastic properties of complex fluids in the frequency range 0.01-10 Hz at different temperatures.
View Article and Find Full Text PDFThe development of lab-on-chip microfluidic systems based on acoustic actuation, and in particular on the acoustophoretic force, has recently attracted significant attention from the scientific community thanks, in part, to the possibility of sample sorting on the basis of both geometrical and mechanical properties. It is commonly recognized that sample prefocusing and launch-position optimization have a substantial effect on the performance of these systems but a clear explanation of how these two parameters influence the system efficiency is still missing. In this manuscript we discuss the impact of both the sample launch position and the sample distribution at the input by the theoretical analysis of a simplified system and by numerical simulations of realistic configurations.
View Article and Find Full Text PDFWe present a simple and practical strategy that allows to design high-efficiency grating couplers. The technique is based on the simultaneous apodization of two structural parameters: the grating period and the fill-factor, along with the optimization of the grating coupler etching depth. Considering a 260 nm Si-thick Silicon-on-insulator platform, we numerically demonstrated a coupling efficiency of -0.
View Article and Find Full Text PDFWe report on the experimental characterization, in the telecom C-band, of group-velocity dispersion (D) in 100-nm high rectangular strip waveguides realized by silicon-on-insulator technology. We compare the experimental results with numerical predictions, showing that 100-nm high waveguides exhibit normal dispersion and that the absolute value of the dispersion coefficient D decreases as the waveguide width is increased. D at 1550 nm varies from -8130 to -3900 ps/(nm·km) by increasing the waveguide width from 500 to 800 nm.
View Article and Find Full Text PDFPhotorefractive-damage- (PRD) resistant zirconium-oxide-doped lithium niobate is investigated as a substrate for the realization of annealed proton-exchanged (APE) waveguides. Its advantages are a favorable distribution coefficient, PRD resistance comparable to magnesium-oxide-doped lithium niobate, and a proton-diffusion behavior resembling congruent lithium niobate. A 1D model for APE waveguides was developed based on a previous model for congruently melting lithium niobate.
View Article and Find Full Text PDFThis paper presents a comprehensive review of the development of the optical stretcher, a powerful optofluidic device for single cell mechanical study by using optical force induced cell stretching. The different techniques and the different materials for the fabrication of the optical stretcher are first summarized. A short description of the optical-stretching mechanism is then given, highlighting the optical force calculation and the cell optical deformability characterization.
View Article and Find Full Text PDFWe realized an integrated microfluidic chip that allows measuring both optical deformability and acoustic compressibility on single cells, by optical stretching and acoustophoresis experiments respectively. Additionally, we propose a measurement protocol that allows evaluating the experimental apparatus parameters before performing the cell-characterization experiments, including a non-destructive method to characterize the optical force distribution inside the microchannel. The chip was used to study important cell-mechanics parameters in two human breast cancer cell lines, MCF7 and MDA-MB231.
View Article and Find Full Text PDFHere we present the results of a study concerning the effect of temperature on cell mechanical properties. Two different optofluidic microchips with external temperature control are used to investigate the temperature-induced changes of highly metastatic human melanoma cells (A375MC2) in the range of ~0 - 35 °C. By means of an integrated optical stretcher, we observe that cells' optical deformability is strongly enhanced by increasing cell and buffer-fluid temperature.
View Article and Find Full Text PDFMonolayers of gold nanostars (GNS) are grafted on mercaptopropyltrimethoxysilane-coated glass slides. In the formed monolayers the localized surface plasmon resonance of GNS can be tuned in the 700-1100 nm range. Upon laser excitation of the nearIR LSPR an efficient photothermal response is observed, inducing local hyperthermia and efficient killing of Staphylococcus aureus biofilms.
View Article and Find Full Text PDFSeveral studies have shown that low-level laser irradiation (LLLI) has beneficial effects on bone regeneration. The objective of this study was to examine the in vitro effects of LLLI on proliferation and differentiation of a human osteoblast-like cell line (Saos-2 cell line). Cultured cells were exposed to different doses of LLLI with a semiconductor diode laser (659 nm; 10 mW power output).
View Article and Find Full Text PDFWe report on stable optical waveguides fabricated by soft-proton exchange in periodically-poled congruent lithium tantalate in the α-phase. The channel waveguides are characterized in the telecom wavelength range in terms of both linear properties and frequency doubling. The measurements yield a nonlinear coefficient of about 9.
View Article and Find Full Text PDFWe experimentally compare the effectiveness of three different optical-phase-conjugation-based nonlinearity-compensation strategies on a transmission system employing phase-modulated signals, and hence affected by the Gordon-Mollenauer effect. We demonstrate that it is possible to obtain significant nonlinearity compensation, but that no improvement is obtained using configurations specifically aimed at the compensation of the nonlinear phase noise.
View Article and Find Full Text PDFThe authors present the design and optimization of an optofluidic monolithic chip, able to provide optical trapping and controlled stretching of single cells. The chip is fabricated in a fused silica glass substrate by femtosecond laser micromachining which can produce both optical waveguides and microfluidic channels with great accuracy. A new fabrication procedure adopted in this work allows the demonstration of microchannels with a square cross-section, thus guaranteeing an improved quality of the trapped cell images.
View Article and Find Full Text PDFWe report the observation of Gaussian beam fragmentation into Airy-like waveforms during nonlinear propagation. The effect is supported by the high-intensity photovoltaic nonlinearity arising in unbiased pure congruent lithium niobate. The process is found to occur when the nonlinear response is dominated by the nonlocal effects associated with the charge-displacement process.
View Article and Find Full Text PDFMeasurements of birefringence, second-harmonic phase-matching conditions, and nonlinear coefficient d(31) are performed for a set of Hafnium-doped congruent lithium niobate (Hf:cLN) crystals as functions of dopant concentration. The data highlight that the threshold concentration, above which there is a change in the Hf incorporation mechanism, is slightly above 2mol% and that, up to this value of concentration, the efficiency of nonlinear processes is not affected by the dopant insertion. Combining these results with those already present in literature, Hf:cLN crystals appear to be very promising candidates for the development of photorefractivity-free wavelength converters working at room temperature.
View Article and Find Full Text PDFWe show a new graphical method to identify and create configurations yielding to nonlinearity compensation in a fiber transmission system. Method validity is shown with regards to different link configurations and different compensation techniques. It is demonstrated that a unifying principle can always be applied, because only one physical effect is involved, even if different practical arrangements are proposed.
View Article and Find Full Text PDF