Background: Intervention on type B dissection frequently requires landing the proximal edge of the stent graft between the left common carotid artery and left subclavian artery (LSA). The GORE TAG thoracic branch endoprosthesis is a technology that allows LSA preservation with a single internal branch.
Methods: This study was a prospective nonrandomized single-arm clinical trial of patients with type B aortic dissection who were treated with the single-branched device.
Objective: Hostile aortic neck anatomies such as proximal short necks are known to put patients at an increased risk for type IA endoleaks, migration, and need for reinterventions. The Heli-FX EndoAnchor System was designed to improve seal of aortic stent grafts. Endosuture aneurysm repair (ESAR) using EndoAnchors with the Endurant stent graft has been shown to be safe and effective for the treatment of patients with short necks through one year.
View Article and Find Full Text PDFMaterials (Basel)
July 2023
In situ fenestration of endovascular stent-grafts has become a mainstream bailout technique to treat complex emergent aneurysms while maintaining native anatomical visceral and aortic arch blood supplies. Fabric tearing from creating the in situ fenestration using balloon angioplasty may extend beyond the intended diameter over time. Further tearing may result from the physiologic pulsatile motion at the branching site.
View Article and Find Full Text PDFEndovascular aortic repair has been increasingly used to treat a multitude of thoracic aorticpathologies. When placement of a thoracic endograft necessitates coverage of one or more of the great vessels, in situ laser fenestration is a safe and effective option for supra-aortic trunk revascularization. Certain anatomic factors may render laser fenestration more technically challenging, particularly depending on aortic arch type and branch vessel characteristics.
View Article and Find Full Text PDFObjective: To provide the 5-year outcomes of the use of a composite device (proximal covered stent graft + distal bare stent) for endovascular repair of patients with acute, type B aortic dissection complicated by aortic rupture and/or malperfusion.
Methods: Study of Thoracic Aortic Type B Dissection Using Endoluminal Repair (STABLE) II was a prospective, multicenter study of the Zenith Dissection Endovascular System (William Cook Europe). Patients were enrolled between August 2012 and January 2015 at sites in the United States and Japan.
A 65-year-old woman had presented with a ruptured type B intramural hematoma associated with a right-sided aortic arch aneurysm, a large Kommerell diverticulum (KD) and an aberrant left subclavian artery (LSA). She underwent total aortic arch replacement with elephant trunk, thoracic endovascular aortic repair, and LSA ligation distal to the left vertebral artery. She subsequently developed a brisk type II endoleak into the KD via retrograde flow from the left vertebral artery.
View Article and Find Full Text PDFObjective: Thoracic endovascular aortic repair (TEVAR) is increasingly utilized in the management of acute type B aortic intramural hematoma (TBIMH). Optimal timing for intervention has not been described. The aim of this study was to evaluate TEVAR timing on postoperative aortic remodeling.
View Article and Find Full Text PDFWe present a case series of 4 iatrogenic ascending aortic pseudoaneurysms that were all successfully repaired with a percutaneous approach. Pre-procedural imaging, device selection, and procedural techniques are described. With careful preparation and patient selection, catheter closure of iatrogenic ascending aortic pseudoaneurysms can be performed reliably and safely.
View Article and Find Full Text PDFObjective: Thoracic endovascular aortic repair (TEVAR) has become first-line therapy for complicated acute type B aortic dissection (aTBAD). However, the strategy for optimal proximal landing zone remains to be determined. We compared early outcomes and late aortic-related adverse events in patients undergoing TEVAR for complicated aTBAD with endograft deployment in proximal landing zone 2 vs 3.
View Article and Find Full Text PDFWe present the novel application of transcarotid artery revascularization (TCAR) in two high-risk patients with high-grade internal artery stenosis and concomitant atherosclerotic extracranial carotid artery aneurysms (ECAAs). ECAAs account for <1% of arterial aneurysms and are usually clinically silent at presentation. Historically, the treatment of ECAAs has been via open reconstruction or stent grafting.
View Article and Find Full Text PDFBackground: The increasing proportion of elderly patients being treated for abdominal aortic aneurysm (AAA) in the endovascular era is controversial.
Objectives: This study compared 30-day outcomes of endovascular aortic repair (EVAR) in nonagenarians (NAs) with non-nonagenarians (NNAs).
Methods: This retrospective analysis of the American College of Surgeons National Surgical Quality Improvement Program database included EVAR procedures performed from 2011 to 2017.
Background: Treatment options for dialysis access steal syndrome (DASS) include distal revascularization with interval ligation (DRIL), proximalization of arterial inflow (PAI), access banding, and access ligation. This study examines the efficacy of DRIL in treating DASS and reports short-term bypass patency, access patency, and wound infection rates.
Methods: A retrospective analysis was performed on adults diagnosed with DASS following hemo-dialysis access creation who underwent DRIL procedures between January 1, 2009 and May 11, 2017.
Authors' Note: On February 17, 2021, Medtronic Incorporated issued a global voluntary recall of the Valiant Navion Thoracic Stent Graft System (the device under study in the Valiant Evo Global Clinical Program that is the subject of this publication), and instructed physicians to immediately cease use of the Valiant Navion system and return any unused product. Medtronic initiated the recall in response to three clinical trial subjects recently observed with stent fractures, two of whom have confirmed type IIIb endoleaks. The data collection, analysis, and manuscript submission occurred before the notice of this recall, and, specifically, the 100 procedures reviewed for this series were free of events at 1 year related to the reason for this device recall.
View Article and Find Full Text PDFBackground: Central venous occlusive disease is a common cause of upper extremity arteriovenous access dysfunction in hemodialysis patients. When refractory to balloon angioplasty, the treatment options include central venous stenting and hemodialysis reliable outflow (HeRO; Merit Medical, South Jordan, Utah) graft. The purpose of the present study was to evaluate the outcomes of these options.
View Article and Find Full Text PDFPurpose: To evaluate the response of various stent-grafts after laser fenestration and dilation with noncompliant balloons to determine the optimal therapeutic combination for this treatment technique.
Materials And Methods: Five aortic stent-grafts were evaluated ex vivo: the Bolton RelayPlus, Jotec E-vita Thoracic 3G, Medtronic Valiant, Cook Zenith Alpha, and Vascutek Anaconda. Small holes were created using an excimer laser with the grafts submerged in saline.
Objective: The short- and mid-term outcomes of endovascular aortic aneurysm repair have made it a standard treatment of abdominal aortic aneurysms. However, newer generation devices have yet to demonstrate improved long-term rates for complications, reinterventions, and survival. The TREO stent graft is a latest generation device and was evaluated for approval in the United States.
View Article and Find Full Text PDFObjective: To evaluate and compare studies reporting the outcomes of the use of covered balloon-expandable (CBE) stents for the treatment of aortoiliac occlusive disease.
Methods: A systematic literature search was conducted to identify studies that investigated the use of CBE stents for the treatment of aortoiliac occlusive disease and were published between 2000 and 2019. Baseline demographic data, procedural variables, and long-term outcomes were extracted from publications for analysis.
Purpose: To assess the midterm safety and effectiveness of the Gore Viabahn Balloon-Expandable Endoprosthesis (VBX Stent-Graft) in the treatment of patients with de novo or restenotic aortoiliac lesions.
Materials And Methods: The prospective, multicenter, nonrandomized, single-arm VBX FLEX clinical study ( identifier: NCT02080871) evaluated 134 patients (mean age 66±9.5 years; 79 men) up to 3 years after treatment with the VBX Stent-Graft.
Objective: Intramural hematoma (IMH) is on the spectrum of acute aortic syndrome, but optimal management is poorly understood. The aim of this study was to evaluate outcomes of patients with type B IMH (TBIMH) after best medical therapy (BMT) and to assess for risk factors associated with failure of BMT.
Methods: This is a single-institution retrospective chart review of all patients with TBIMH between January 2008 and December 2017.
Takayasu's arteritis (TA) is a systemic large vessel vasculitis that affects the aorta and its branches. Most patients with TA respond to medical therapy with a minority of patients requiring surgical intervention. In our report, we describe the case of a 59-year-old Caucasian female with TA who underwent revascularization due to cerebrovascular symptoms refractory to medical therapy.
View Article and Find Full Text PDFObjective: To evaluate the safety and effectiveness of a composite device design (covered stent graft and bare metal stent) for the treatment of patients with acute, complicated type B aortic dissection (TBAD) presenting with aortic rupture and/or branch vessel malperfusion.
Methods: In this prospective, nonrandomized, multicenter study, 73 patients (65.8% male; mean age, 60.