Publications by authors named "Pancaldi D"

Purpose: In recent years the use of Ga (t = 67.84 min, β: 88.88%) for the labelling of different PET radiopharmaceuticals has significantly increased.

View Article and Find Full Text PDF

In the planning of a new cyclotron facility, an accurate knowledge of the radiation field around the accelerator is fundamental for the design of shielding, the protection of workers, the general public and the environment. Monte Carlo simulations can be very useful in this process, and their use is constantly increasing. However, few data have been published so far as regards the proper validation of Monte Carlo simulation against experimental measurements, particularly in the energy range of biomedical cyclotrons.

View Article and Find Full Text PDF

Radiation protection (RP) in the use of medical cyclotrons involves many aspects both in the routine use and for the decommissioning of a site. Guidelines for site planning and installation, as well as for RP assessment, are given in international documents; however, the latter typically offer analytic methods of calculation of shielding and materials activation, in approximate or idealised geometry set-ups. The availability of Monte Carlo (MC) codes with accurate up-to-date libraries for transport and interaction of neutrons and charged particles at energies below 250 MeV, together with the continuously increasing power of modern computers, makes the systematic use of simulations with realistic geometries possible, yielding equipment and site-specific evaluation of the source terms, shielding requirements and all quantities relevant to RP at the same time.

View Article and Find Full Text PDF

Radionuclide activity meters ("dose calibrators") are ionization chambers designed to measure relatively high amount of activities which are normally contained in radiopharmaceuticals. However, in the current radiopharmacy practice, these radiation detectors have been proposed to be used in measurements of samples with lower activity, such as in routine quality control (QC) tests. To check the feasibility of such measurements, in this work we assessed the performance of four different devices in the lower range of detectability, by means of experimental measurements of a radioactive sample.

View Article and Find Full Text PDF

In a medical cyclotron facility, (41)Ar (t1/2 = 109.34 m) is produced by the activation of air due to the neutron flux during irradiation, according to the (40)Ar(n,γ)(41)Ar reaction; this is particularly relevant in widely diffused high beam current cyclotrons for the production of PET radionuclides. While theoretical estimations of the (41)Ar production have been published, no data are available on direct experimental measurements for a biomedical cyclotron.

View Article and Find Full Text PDF

In the last years (68)Ga has got into the focus of researchers and clinicians especially for radio-labeling of biomolecules; an important characteristic of this positron emitting isotope is its availability via the (68)Ge/(68)Ga generator system: the long-lived (68)Ge (t1/2=270.8 d) produces the short-lived (68)Ga (t1/2=67.63 min) which decays to stable (68)Zn.

View Article and Find Full Text PDF

Cyclotrons dedicated to the production of PET radiopharmaceuticals for clinical use can be a resource also for research in other fields of science. In the present study we assessed the feasibility of (65)Zn production via the (65)Cu(p,n)(65)Zn reaction using a 16.5 MeV GE-PETtrace biomedical cyclotron.

View Article and Find Full Text PDF

The widely used Monte Carlo simulation code FLUKA has been utilized to prototype a solid target for the production of (89)Zr by irradiation of a metallic (89)Y target foil in a 16.5MeV proton biomedical cyclotron, through the reaction (89)Y(p, n)(89)Zr. Simulations were performed with and without an Al energy degrader.

View Article and Find Full Text PDF

Rice (Oryza sativa L.) is cultivated on approximately 230,000 ha in northern Italy. Since 2001, increasing economical losses presumably caused by Fusarium fujikuroi Nirenberg (Gibberella fujikuroi mating population C), an exotic fungus known as the etiological agent of Bakanae disease, have been reported in Italy.

View Article and Find Full Text PDF

Ozone produced from radiolytic processes was investigated as a possible health hazard in the working environment at the University Hospital "S.Orsola--Malpighi" PET facility. Intense radiation fields can generate ozone, known to be the most toxic gas produced by ionizing radiation around a particle accelerator.

View Article and Find Full Text PDF

Introduction And Aim: Scintigraphic imaging of infection and inflammation with 67Ga-citrate is an established and powerful diagnostic tool in the management of patients with infectious or inflammatory diseases. 68Ga is a short-lived positron-emitting radionuclide (half-life 67.6 min, positron energy 2.

View Article and Find Full Text PDF

Aim: To estimate the radiation dose delivered from patients injected with yttrium-90 (Y)-labelled tiuxetan (Zevalin) to parents and the general population, comparing different techniques.

Methods: The radiation dose delivered from a group of eight patients injected with Y-Zevalin to treat recurrent lymphoma was measured. The data obtained with the Monte Carlo simulation test were compared with the experimental measurements obtained with an ionization chamber detector and with a crystal NaI(Tl) detector.

View Article and Find Full Text PDF

Somatostatin receptors 1-5 are over expressed in neuroendocrine tumours (NETs). 68Ga-labelled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-Nal3-Octreotide (DOTA NOC), a recent synthesized somatostatin analogue, shows high affinity for those receptors. Herein, modifications of a commercial module for the labelling of DOTA NOC with 68Ga, as well as the assessment of time course of the radiochemical purity variation are described.

View Article and Find Full Text PDF

In this paper, radionuclidic impurities generated during the bombardment of [18 O]water in the routine production of 2-[18F]fluoro-2-deoxy-d-glucose ([18F]FDG) were studied. In order to assess such impurities and the efficacy of purification methods through the different steps of the synthesis, samples of the target filters, purification columns, [18 O]water recovered after the synthesis, and the final solution was collected and their activities measured and analyzed by means of a gamma-ray spectrometry system. The data demonstrated that purification methods adopted for the synthesis provide the [18F]FDG radionuclidically pure, as requested by the EU Pharmacopeia.

View Article and Find Full Text PDF

A multicentre survey of the quality control of 99Tcm generators has been completed: 245 generators from seven different commercial sources were tested over a period of 2 years. The results indicate that the mean pH of the eluates was 5.8 +/- 0.

View Article and Find Full Text PDF

Pertechnegas is a new ventilation agent produced by modifying the atmosphere of combustion of Technegas. Due to its rapid disappearance from the lungs, Pertechnegas has been suggested as useful in measuring pulmonary epithelial permeability. This study aimed to assess the reliability of ventilation scans with Pertechnegas to evaluate alveolar-capillary permeability.

View Article and Find Full Text PDF

The synthesis of pyrazolyl-amides of aminoacids and peptides is described. The chemicals were tested for antifungal activity against wheat powdery mildew (Erysiphe graminis DC.), cucumber powdery mildew (Erysiphe cichoracearum DC.

View Article and Find Full Text PDF

The synthesis of 4-nitroso-5-amminopyrazoles and of 4-nitroso-5-pyrazolylurethans and -ureas is described. The chemicals were tested for antifungal activity against Erysiphe graminis, Erysiphe cichoracearum, Puccinia recondita, Septoria apii and Rhizoctonia solani. A number of the described compounds showed some antifungal activity.

View Article and Find Full Text PDF