Publications by authors named "Panayot Petrov"

Article Synopsis
  • A novel methodology combining asymmetrical flow field-flow fractionation (AF4) with ICP-MS and size fraction-targeted isotope dilution analysis (IDA) has been developed to measure nanoscale silica (SiO) mass fractions.
  • The approach involved synthesizing and characterizing Si-enriched SiO nanoparticles for use as internal standards in double and single IDA analyses, achieving measurement uncertainties of 4% and 8% in different matrices.
  • The method demonstrated high accuracy with a recovery rate of 95.6% in food samples, and results from IDA correlated well with those from external calibration, indicating effectiveness in characterizing nanoscale silica.
View Article and Find Full Text PDF

Species-specific isotope dilution mass spectrometry (SS-IDMS) has been the calibration method of choice for high accuracy speciation analysis because it can correct for detector sensitivity drifts, matrix effects, and analyte loss during sample preparation and analysis. However, in many cases SS-IDMS calibration is either not applicable (e.g.

View Article and Find Full Text PDF

Long-lived high abundance radionuclides are of increasing interest with regard to decommissioning of nuclear sites and longer term nuclear waste storage and disposal. In many cases, no routine technique is available for their measurement in nuclear waste and low-level (ng kg) environmental samples. Recent advances in ICP-MS technology offer attractive features for the selective and sensitive determination of a wide range of long-lived radionuclides.

View Article and Find Full Text PDF

Polybrominated diphenylethers (PBDE), used as flame retardants, are named as priority substances in the Directive 2000/60/EC of the European parliament and of the council establishing a framework for Community action in the field of water policy. An annual average environmental quality standard (EQS) for inland surface waters of 0.0005 µg/L (0.

View Article and Find Full Text PDF

One of the unresolved issues of the European Water Framework Directive is the unavailability of realistic water reference materials for the organic priority pollutants at low nanogram-per-liter concentrations. In the present study, three different types of ready-to-use water test materials were developed for polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) at nanogram-per-liter levels. The first type simulated the dissolved phase in the water and comprised of a solution of humic acids (HA) at 5 mg L(-1) dissolved organic carbon (DOC) and a spike of the target compounds.

View Article and Find Full Text PDF

Methodology for absolute Mo isotope amount ratio measurements by multicollector inductively coupled plasma-mass spectrometry (MC-ICP-MS) using calibration with synthetic isotope mixtures (SIMs) is presented. For the first time, synthetic isotope mixtures prepared from seven commercially available isotopically enriched molybdenum metal powders ((92)Mo, (94)Mo, (95)Mo, (96)Mo, (97)Mo, (98)Mo, and (100)Mo) are used to investigate whether instrumental mass discrimination of Mo isotopes in MC-ICP-MS is consistent with mass-dependent isotope distribution. The parent materials were dissolved and mixed as solutions to obtain mixtures with accurately known isotope amount ratios.

View Article and Find Full Text PDF

In this work, 13 selenium species in flue gas desulfurization (FGD) waters from coal-fired power plants were separated and quantified using anion-exchange chromatography coupled to inductively coupled plasma mass spectrometry. For the first time, we identified both selenosulfate (SeSO(3)(2-)) and selenocyanate (SeCN(-)) in such waters, using retention time matching and confirmation by electrospray mass spectrometry. Besides selenite and selenate, selenosulfate was the most frequently occurring selenium species.

View Article and Find Full Text PDF

Analytical procedure for the determination of toxicologically relevant arsenic (the sum of arsenite, arsenate, monomethylarsonate and dimethylarsinate) in urine by flow injection hydride generation and collection of generated inorganic and methylated hydrides on an integrated platform of a transverse-heated graphite atomizer for electrothermal atomic absorption spectrometric determination (ETAAS) is elaborated. Platforms are pre-treated with 2.7 micromol of zirconium and then with 0.

View Article and Find Full Text PDF