COVID-19-induced "acute respiratory distress syndrome" (ARDS) is associated with prolonged respiratory failure and high mortality, but the mechanistic basis of lung injury remains incompletely understood. Here, we analyze pulmonary immune responses and lung pathology in two cohorts of patients with COVID-19 ARDS using functional single-cell genomics, immunohistology, and electron microscopy. We describe an accumulation of CD163-expressing monocyte-derived macrophages that acquired a profibrotic transcriptional phenotype during COVID-19 ARDS.
View Article and Find Full Text PDFBackground: Limited data are available concerning the safety, optimal administration and benefits of contemporary heart failure therapy in patients after left ventricular assist device (LVAD) implantation.
Methods: Between 2015 and 2019, 257 patients underwent LVAD implantation and were included in this observational study. Oral heart failure therapy was initiated and uptitrated during the further course.
Background: In face of the Coronavirus Disease (COVID)-19 pandemic, best practice for mechanical ventilation in COVID-19 associated Acute Respiratory Distress Syndrome (ARDS) is intensely debated. Specifically, the rationale for high positive end-expiratory pressure (PEEP) and prone positioning in early COVID-19 ARDS has been questioned.
Methods: The first 23 consecutive patients with COVID-19 associated respiratory failure transferred to a single ICU were assessed.
Background Several risk models target the issue of posttransplant survival, but none of them have been validated in a large European cohort. This aspect is important, in a time of the planned change of the Eurotransplant allocation system to a scoring system. Material and Methods Data of 761 heart transplant recipients from the Eurotransplant region with a total follow up of 5027 patient-years were analyzed.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
October 2018
Objective: We present a novel machine learning model to accurately predict the blood-analog viscosity during support of a pathological circulation with a rotary ventricular assist device (VAD). The aim is the continuous monitoring of the hematocrit (HCT) of VAD patients with the benefit of a more reliable pump flow estimation and a possible early detection of adverse events, such as bleeding or pump thrombosis.
Methods: A large dataset was generated with a blood pump connected to a hybrid mock circulation by varying the pump speed, the physiological requirements of the modeled circulation, and the viscosity of the blood-analog.
The current paper analyzes the performance of a physiological controller for turbodynamic ventricular assist devices (tVADs) during acute patho-physiological events. The numerical model of the human blood circulation implemented on our hybrid mock circulation was extended in order to simulate the Valsalva maneuver (VM) and premature ventricular contractions (PVCs). The performance of an end-diastolic volume (EDV)-based physiological controller for VADs, named preload responsive speed (PRS) controller was evaluated under VM and PVCs.
View Article and Find Full Text PDFMediastinitis is more frequent in patients with implantable ventricular assist devices (VADs) than in other cardiac surgery patients and carries significant mortality. We report our experience with a stepwise approach including aggressive debridement, jet lavage, vacuum assisted closure dressing, and finally coverage with well-vascularized and immune-active omental flaps in VAD patients with infective mediastinitis. We retrospectively collected and analyzed data of patients with continuous flow VAD who underwent plasty with the omental flap because of mediastinitis at Deutsches Herzzentrum Berlin between January 1, 2008 and October 30, 2015.
View Article and Find Full Text PDFBackground And Aim Of The Study: Driveline infections in patients with implantable left ventricular assist devices (VAD) carry increasing risk for pump infection, thromboembolic events, decreased quality of life, and increased hospitalization. We report our experience with a surgical technique for refractory driveline infections without mediastinitis consisting of translocation and wrapping of the driveline with greater omentum tissue.
Methods: We retrospectively reviewed data of VAD patients who underwent surgical treatment by translocation and wrapping with omentum for severe chronic driveline infection.
The current article presents a novel physiological feedback controller for turbodynamic ventricular assist devices (tVADs). This controller is based on the recording of the left ventricular (LV) pressure measured at the inlet cannula of a tVAD thus requiring only one pressure sensor. The LV systolic pressure (SP) is proposed as an indicator to determine the varying perfusion requirements.
View Article and Find Full Text PDFBackground: Thrombosis is an uncommon, but severe complication of left ventricular assist devices (LVADs).
Objectives: This study analyzed experience with obstruction of blood flow through the LVAD with the purpose of developing optimal diagnosis and treatment of LVAD-related thrombosis.
Methods: Between October 2009 and July 2015, a total of 652 LVAD were implanted in 557 patients.