Introduction: Modified ultrafiltration (MUF) is employed at the termination of cardiopulmonary bypass (CPB) in pediatric and neonatal patients undergoing congenital heart surgery to reduce the accumulation of total body water thus increasing the concentration of red blood cells and the other formed elements in the circulation. Modified ultrafiltration has been reported to remove circulating pro-inflammatory mediators that result in systemic inflammatory response syndrome (SIRS) postoperatively.
Methods: Four hundred patients undergoing cardiac surgery requiring cardiopulmonary bypass and weighing less than or equal to 12 kg were retrospectively evaluated for the effectiveness of MUF.
Translational research is a useful tool to provide scientific evidence for cannula selection during extracorporeal life support (ECLS). The objective of this study was to evaluate four Avalon Elite bi-caval dual lumen cannulas and nine femoral arterial cannulas in terms of flow range, circuit pressure, pressure drop, and hemodynamic energy transmission in a simulated adult ECLS model. A veno-venous ECLS circuit was used to evaluate four Avalon Elite bi-caval dual lumen cannulas (20, 23, 27, and 31 Fr), and a veno-arterial ECLS circuit was used to evaluate nine femoral arterial cannulas (15, 17, 19, 21, and 23 Fr).
View Article and Find Full Text PDFThe use of ECMO for cardiovascular support continues to increase in the United States and around the world. It is not a benign endeavor as serious complications may occur. We present our experience of two second generation CentriMag (Abbott formerly Thoratec Inc.
View Article and Find Full Text PDFThe objective of this study was to compare three different hemoconcentrators (Hemocor HPH 400, Mini, and Junior) with two different neonatal ECMO circuits using a roller or a centrifugal pump at different pseudo-patient pressures and flow rates in terms of hemodynamic properties. This evidence-based research is necessary to optimize the ECMO circuitry for neonates. The circuits used a 300-mL soft-shell reservoir as a pseudo-patient approximating the blood volume of a 3 kg neonate, two blood pumps, and a Quadrox-iD Pediatric oxygenator with three different in-line hemoconcentrators (Hemocor HPH 400, Mini, and Junior).
View Article and Find Full Text PDFThe objective of this study was to evaluate five small-bore arterial cannulae (6Fr and 8Fr) in terms of pressure drop and hemodynamic performance in simulated neonatal cardiopulmonary bypass (CPB) circuits. The experimental circuits consisted of a Jostra HL-20 roller pump, a Terumo Capiox Baby FX05 oxygenator with integrated arterial filter, an arterial and a venous tubing (1/4, 3/16, or 1/8 in × 150 cm), and an arterial cannula (Medtronic Bio-Medicus 6Fr and 8Fr, Maquet 6Fr and 8Fr, or RMI Edwards 8Fr). The circuit was primed using lactated Ringer's solution and heparinized packed human red blood cells (hematocrit 30%).
View Article and Find Full Text PDFThe objectives of this study were to investigate the relationship between revolution speed of a conventional centrifugal pump and negative pressure at the inlet of the pump by clamping the tubing upstream of the pump, and to verify whether negative pressure leads to gaseous microemboli (GME) production in a simulated adult extracorporeal life support (ECLS) system. The experimental circuit, including a Maquet Rotaflow centrifugal pump and a Medos Hilite 7000 LT polymethyl-pentene membrane oxygenator, was primed with packed red blood cells (hematocrit 35%). Negative pressure was created in the circuit by clamping the tubing upstream of the pump for 10 s, and then releasing the clamp.
View Article and Find Full Text PDFThe purpose of this investigation was to compare the hemolysis levels for patients on extracorporeal membrane oxygenation (ECMO) incorporating two different rotary blood pumps (CentriMag [CMAG] and RotaFlow [RF]) in identical circuits otherwise. The difference between the two pumps is the cost. One is 20-30 times less expensive than the other.
View Article and Find Full Text PDFUltrafiltration, which is currently considered as a standard method to remove excess water administered during pediatric cardiopulmonary bypass (CPB), aims to minimize the adverse effects of hemodilution, such as tissue edema and blood transfusion. Three ultrafiltration techniques can be used before, during and after CPB procedures, including conventional ultrafiltration (CUF), modified ultrafiltration (MUF) and zero-balance ultrafiltration (Z-BUF). These methods are widely different, but they have common benefits on hemoconcentration, less requirement for blood products, and reduction of the systemic inflammatory responses (SIRS).
View Article and Find Full Text PDFThis review on the benefits of pulsatile flow includes not only experimental and clinical data, but also attempts to further illuminate the major factors as to why this debate has continued during the past 55 years. Every single component of the cardiopulmonary bypass (CPB) circuitry is equally important for generating adequate quality of pulsatility, not only the pump. Therefore, translational research is a necessity to select the best components for the circuit.
View Article and Find Full Text PDFIn previous studies, we have evaluated the hemodynamic properties of selected oxygenators, pumps (centrifugal and roller), and single lumen cannulae. Because the dual lumen cannulae are widely used in veno-venous extracorporeal life support (ECLS) and are receiving popularity due to their advantages over the single lumen cannulae, we evaluated the flow ranges and pressure drops of three different sizes of Avalon Elite dual lumen cannulae (13Fr, 16Fr, and 19Fr) in a simulated neonatal ECLS circuit primed with human blood. The experimental ECLS circuit was composed of a RotaFlow centrifugal pump, a Capiox BabyRX05 oxygenator, 3 ft of 1/4-in venous and arterial line tubing, an Avalon Elite dual lumen cannula, and a soft reservoir as a pseudo-right atrium.
View Article and Find Full Text PDFWorld J Pediatr Congenit Heart Surg
July 2011
Over the past 6 years at Penn State Hershey, we have established the pediatric cardiovascular research center with a multidisciplinary research team with the goal to improve the outcomes for children undergoing cardiac surgery with cardiopulmonary bypass (CPB) and extracorporeal life support (ECLS). Due to the variety of commercially available pediatric CPB and ECLS devices, both in vitro and in vivo translational research have been conducted to achieve the optimal choice for our patients. By now, every component being used in our clinical settings in Penn State Hershey has been selected based on the results of our translational research.
View Article and Find Full Text PDFBlood cardioplegia delivery systems are employed in most pediatric open heart cases to arrest the heart and keep it preserved during aortic cross-clamping. They are also used as part of a modified ultrafiltration system at the end of cardiopulmonary bypass. We evaluated and compared the air-handling capabilities of different types of blood cardioplegia delivery devices.
View Article and Find Full Text PDF