Objective: The LungFlag risk prediction model uses individualized clinical variables to identify individuals at high-risk of non-small cell lung cancer (NSCLC) for screening with low-dose computed tomography (LDCT). This study evaluates the cost-effectiveness of LungFlag implementation in the Spanish setting for the identification of individuals at high-risk of NSCLC.
Methods: A model combining a decision-tree with a Markov model was adapted to the Spanish setting to calculate health outcomes and costs over a lifetime horizon, comparing two hypothetical scenarios: screening with LungFlag versus non-screening, and screening with LungFlag versus screening the entire population meeting 2013 US Preventive Services Task Force (USPSTF) criteria.
Malignant pleural effusion (MPE) has become an increasingly prevalent complication in oncological patients, negatively impacting their quality of life and casting a shadow over their prognosis. Owing to the pathophysiological mechanisms involved and the heterogeneous nature of the underlying disease, this entity is both a diagnostic and therapeutic challenge. Advances in the understanding of MPE have led to a shift in the treatment paradigm towards a more personalized approach.
View Article and Find Full Text PDFBackground: Hemoptysis is a challenging and potentially life-threatening medical condition. The most appropriate diagnostic work-up is debated and several diagnostic approaches are implemented worldwide.
Methods: An international, online survey was carried out to investigate the current practice of the diagnostic work-up of patients with hemoptysis of unknown etiology.
Annu Int Conf IEEE Eng Med Biol Soc
July 2023
The use of electrical impedance spectroscopy for lung tissue differentiation is an opportunity for the improvement of clinical diagnosis. The aim of this work is to distinguish among different lung tissue states by evaluating the differences among impedance spectrum parameters between two separate frequencies (15 kHz and 307 kHz) in the beta dispersion region. In previous studies we have used single frequency measurements for tissue differentiation.
View Article and Find Full Text PDFPurpose: To use minimally-invasive transcatheter electrical impedance spectroscopy measurements for tissue differentiation among healthy lung tissue and pathologic lung tissue from patients with different respiratory diseases (neoplasm, fibrosis, pneumonia and emphysema) to complement the diagnosis at real time during bronchoscopic procedures.
Methods: Multi-frequency bioimpedance measurements were performed in 102 patients. The two most discriminative frequencies for impedance modulus (|Z|), phase angle (PA), resistance (R) and reactance (Xc) were selected based on the maximum mean pair-wise Euclidean distances between paired groups.
The COVID-19 pandemic has been a worldwide medical challenge. Despite rapid advancements, many questions regarding SARS-CoV-2 interaction with other pathologies and long-term consequences remained unanswered. Sarcoidosis is a multi-systemic granulomatous disease that develops in genetically predisposed individuals following their exposure to an environmental trigger.
View Article and Find Full Text PDFJ Bronchology Interv Pulmonol
January 2022
Background: Bronchoalveolar lavage (BAL) is a technique classically used for the study of diffuse interstitial lung diseases (DILDs). Given the recent advances in the diagnosis of DILD by transbronchial cryobiopsy (TBCB), it is relevant to assess what BAL can contribute to TBCB.
Patients And Methods: This is a retrospective descriptive study that included patients with DILD who, between 2013 and 2017, underwent BAL and TBCB in the same bronchoscopy intervention.
Unlabelled: The diagnosis and staging of lung cancer are an important process that identifies treatment options and guides disease prognosis. Therefore, an accurate mediastinal lymph node (LN) staging is required not only to offer the appropriate treatment but also to avoid unnecessary invasive procedures. At present, endobronchial ultrasound (EBUS)-transbronchial needle aspiration is the preferred modality for sampling mediastinal lymph nodes because of its minimally invasive nature and high diagnostic yield.
View Article and Find Full Text PDFBackground: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated.
Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy.
Annu Int Conf IEEE Eng Med Biol Soc
July 2020
Electrical Impedance Spectroscopy has already demonstrated the ability to distinguish different tissues types, or tumors from normal tissue, or tissues displaying diverse degrees of pathology. When applying the technique, however, the necessity to make contact with the tissue often constitutes a practical limitation. Electrical Impedance Imaging (EIT), or in a broader sense, regional impedance assessment, struggle to assess different tissue conditions out of measurements from the surface of the body.
View Article and Find Full Text PDFThe data described in this article are supplementary to our primary article "Platelet factor 4 regulates T cell effector functions in malignant pleural effusions". Malignant pleural effusion (MPE) is a common complication of advanced lung adenocarcinoma (LAC) associated with a poor life expectancy [1]. Several challenges need to be addressed to identify non-invasive molecular biomarkers that help to predict the prognosis of LAC patients with MPE [2].
View Article and Find Full Text PDFBackground: In recent years, transbronchial cryobiopsy (TBCB) has come to be increasingly used in interventional pulmonology units as it obtains larger and better-quality samples than conventional transbronchial lung biopsy (TBLB) with forceps. No multicenter studies have been performed, however, that analyse and compare TBCB and TBLB safety and yield according to the interstitial lung disease (ILD) classification.
Objectives: We compared the diagnostic yield and safety of TBCB with cryoprobe sampling versus conventional TBLB forceps sampling in the same patient.
Introduction: The accurate diagnosis of individual interstitial lung diseases (ILD) is often challenging, but is a critical determinant of appropriate management. If a diagnosis cannot be made after multidisciplinary team discussion (MDTD), surgical lung biopsy is the current recommended tissue sampling technique according to the most recent guidelines. Transbronchial lung cryobiopsy (TBLC) has been proposed as an alternative to surgical lung biopsy.
View Article and Find Full Text PDFMalignant pleural effusion (MPE) is defined as the presence of tumor cells in pleural fluid and it is a fatal complication of advanced lung adenocarcinoma (LAC). To understand the immune response to the tumor in MPE, we compared the concentration of immunomodulatory factors in MPE of LAC and pleural effusion of heart failure (HF) patients by ELISA, and the proliferation and cytotoxic phenotype of T cells stimulated in the presence of LAC and HF pleural fluids by cytometry. Platelet factor 4 (PF4), vascular endothelial growth factor (VEGF), transforming growth factor beta (TGF-β) and P-selectin levels were higher in LAC than in HF pleural fluids.
View Article and Find Full Text PDFThe diagnosis of idiopathic pulmonary fibrosis (IPF) is a complex process that requires the multidisciplinary integration of clinical, radiological, and histological variables. Due to its diagnostic yield, surgical lung biopsy has been the recommended procedure for obtaining samples of lung parenchyma, when required. However, given the morbidity and mortality of this technique, alternative techniques which carry a lower risk have been explored.
View Article and Find Full Text PDFThe presence of leukocyte subpopulations in malignant pleural effusions (MPEs) can have a different impact on tumor cell proliferation and vascular leakiness, their analysis can help to understand the metastatic microenvironment. We analyzed the relationship between the leukocyte subpopulation counts per ml of pleural fluid and the tumor cell count, molecular phenotype of lung adenocarcinoma (LAC), time from cancer diagnosis and previous oncologic therapy. We also evaluated the leukocyte composition of MPEs as a biomarker of prognosis.
View Article and Find Full Text PDF