Knee Surg Sports Traumatol Arthrosc
October 2024
Purpose: To compare the load distributed to the medial tibial articular cartilage after refixation of posterior medial meniscus root tears between the suture anchor and transtibial pullout techniques in posterior medial meniscus root tears.
Methods: Twelve Thiel's embalmed human cadaveric knees are used and divided into three groups (four knees in each group): (1) intact meniscus (IM), (2) fixation with suture anchor technique (SA) and (3) fixation with transtibial pullout technique (TP). Each group applies an axial compression load up to 1500 N by Instron E 10000 at two knee flexion angles (0° and 60°).
We have developed a novel osteosynthesis plate with bone union detection using a wire's natural frequency (BUDWF) to provide the quantitative result of bone union detection. The concept for detecting bone union is measuring the rate of frequency change. The frequency is measured from sound generated from the wire attached to a modified plate.
View Article and Find Full Text PDFJ ISAKOS
August 2024
Objective: To determine the mean contact pressure, peak contact pressure, and mean contact area of the lateral tibiofemoral joint in lateral extra-articular tenodesis (LET) with tension on the graft in tibial neutral and external rotation.
Methods: A total of eight Thiel-embalmed cadaveric knees were prepared and divided into two groups (4 knees in each group): the LET-NR group (lateral extra-articular tenodesis tension in neutral rotation) and (2) the LET-ER group (lateral extra-articular tenodesis tension in external rotation). Each knee was prepared according to the corresponding technique.
Asia Pac J Sports Med Arthrosc Rehabil Technol
January 2024
Background/objective: During the initial stages of rehabilitation after anterior cruciate ligament (ACL) surgery, a pivotal role is played in ensuring effective recuperation and averting complications. An often-employed strategy to tackle ACL laxity during this period involves the incorporation of synthetic materials for reinforcement. The objective of this study is to compare the effectiveness of conventional suture tape and multiple high-strength sutures as augmentation techniques for ACL repair.
View Article and Find Full Text PDFA conventional 4-bar polycentric knee and solid ankle cushion heel foot (SACH foot) have been commonly used in developing countries. However, they cannot perform stance-phase knee flexion, which makes a person with an amputation walk unnaturally and with less stability. This research proposes a novel design of a 4-bar polycentric knee with stance-phase knee flexion ability (4BSF), which can perform both stance and swing-phase knee flexion, like able-bodied gait.
View Article and Find Full Text PDFThe purpose of our biomechanical study was to assess load-to-failure, stiffness, gap formation following cyclic loading, and the failure mechanism for anterior cruciate ligament (ACL) repair comparing the cortical suspensory button and knotless anchor suture. Eight Thiel's embalmed paired cadaveric knees from four cadavers were dissected. The specimens were assigned to undergo ACL repair either with cortical suspensory button or with knotless anchor suture.
View Article and Find Full Text PDFA femoral fracture is a severe injury occurring in traumatic and pathologic causes. Diagnosis and Preoperative planning are indispensable procedures relying on preoperative radiographs such as X-ray and CT images. Nevertheless, CT imaging has a higher cost, radiation dose, and longer acquisition time than X-ray imaging.
View Article and Find Full Text PDFUnlabelled: Outcomes of users provided with a commercial ESR Vari-Flex foot (Össur, Reykjavik, Iceland) and a locally designed sPace foot were investigated. Step activity with users' own prosthetic foot compared to the sPace foot was explored.
Methods: Eleven individuals with unilateral trans-tibial amputation participated and were provided with an sPace and Vari-Flex foot.
Excessive postural sway while standing can lead to falls and injuries. A designed wearable balance assistance device which consists of scissored-pair control moment gyroscopes and a two-axis inclination sensor is introduced to reduce fall risk from excessive sway among the elderly. The prototype has dimensions of H50cm × W44cm × D30cm and weighs 15.
View Article and Find Full Text PDFDisabil Rehabil Assist Technol
February 2021
Background: Hydraulic knee prosthesis can provide stance phase control and swing phase control suitable for active persons with an amputation. However, typical commercial hydraulic knees are costly and require frequent maintenance making them inaccessible for persons with an amputation in low-income countries. The objective of this article is to present a new design for a low-cost hydraulic knee prosthesis.
View Article and Find Full Text PDFImpaired balance control ability and degraded functional mobility increases the risk of falling in elderly people. The elderly show more postural sway when standing compared with young people. A sway fall occurs when the center of gravity moves outside the limit of stability.
View Article and Find Full Text PDFIEEE Trans Neural Syst Rehabil Eng
June 2018
In hand prosthesis design, the important characteristics that directly affect hand performance are the ability to grasp various type of objects, grasping force that provides stability for holding objects, and cosmetic appearance that resembles the human hand. The presence of all of these characteristics is currently a challenging task for prosthesis design. This paper presents the design of a five-fingered prosthetic hand that has multiple grip patterns with the use of only one actuator in order to perform important tasks in daily life and which achieves significant grip force from the large size of the actuator.
View Article and Find Full Text PDFBackground: The alignment of the lower limb prosthesis is an integral part of the prosthetic fitting. A properly aligned prosthesis contributes to optimal gait and overall function of the patient. The current offering of alignment componentry is expensive for low-income countries.
View Article and Find Full Text PDFStudy Design: An experimental study.
Objective: To analyze the effects of a modified U-shape interspinous distraction device (IDD) on the stability of a destabilized lumbar spine model.
Summary Of Background Data: The use of IDD for treatment of lumbar spine pathology remains a subject of debate.