Publications by authors named "Paganin D"

In recent years, a novel x-ray imaging modality has emerged that reveals unresolved sample microstructure via a "dark-field image", which provides complementary information to conventional "bright-field" images, such as attenuation and phase-contrast modalities. This x-ray dark-field signal is produced by unresolved microstructures scattering the x-ray beam resulting in localised image blur. Dark-field retrieval techniques extract this blur to reconstruct a dark-field image.

View Article and Find Full Text PDF

Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates `unreasonable' effectiveness of the method.

View Article and Find Full Text PDF

X-ray diffusive dark-field imaging, which allows spatially unresolved microstructure to be mapped across a sample, is an increasingly popular tool in an array of settings. Here, we present a new algorithm for phase and dark-field computed tomography based on the x-ray Fokker-Planck equation. Needing only a coherent x-ray source, sample, and detector, our propagation-based algorithm can map the sample density and dark-field/diffusion properties of the sample in 3D.

View Article and Find Full Text PDF

A set of non-configurable transversely-displaced masks has been designed and fabricated to generate high-quality X-ray illumination patterns for use in imaging techniques such as ghost imaging (GI), ghost projection, and speckle tracking. The designs include a range of random binary and orthogonal patterns, fabricated through a combination of photolithography and gold electroplating techniques. We experimentally demonstrated that a single wafer can be used as an illumination mask for GI, employing individual illumination patterns and also a mixture of patterns, using a laboratory X-ray source.

View Article and Find Full Text PDF

The size of the smallest detectable sample feature in an x-ray imaging system is usually restricted by the spatial resolution of the system. This limitation can now be overcome using the diffusive dark-field signal, which is generated by unresolved phase effects or the ultra-small-angle x-ray scattering from unresolved sample microstructures. A quantitative measure of this dark-field signal can be useful in revealing the microstructure size or material for medical diagnosis, security screening and materials science.

View Article and Find Full Text PDF

Emerging methods of x-ray imaging that capture phase and dark-field effects are equipping medicine with complementary sensitivity to conventional radiography. These methods are being applied over a wide range of scales, from virtual histology to clinical chest imaging, and typically require the introduction of optics such as gratings. Here, we consider extracting x-ray phase and dark-field signals from bright-field images collected using nothing more than a coherent x-ray source and a detector.

View Article and Find Full Text PDF

Speckle-based phase-contrast X-ray imaging (SB-PCXI) can reconstruct high-resolution images of weakly-attenuating materials that would otherwise be indistinguishable in conventional attenuation-based X-ray imaging. The experimental setup of SB-PCXI requires only a sufficiently coherent X-ray source and spatially random mask, positioned between the source and detector. The technique can extract sample information at length scales smaller than the imaging system's spatial resolution; this enables multimodal signal reconstruction.

View Article and Find Full Text PDF

The state of a classical point-particle system may often be specified by giving the position and momentum for each constituent particle. For non-pointlike particles, the center-of-mass position may be augmented by an additional coordinate that specifies the internal state of each particle. The internal state space is typically topologically simple, in the sense that the particle's internal coordinate belongs to a suitable symmetry group.

View Article and Find Full Text PDF

Characterizing the properties of X-ray free-electron laser (XFEL) sources is a critical step for optimization of performance and experiment planning. The recent availability of MHz XFELs has opened up a range of new opportunities for novel experiments but also highlighted the need for systematic measurements of the source properties. Here, MHz-enabled beam imaging diagnostics developed for the SPB/SFX instrument at the European XFEL are exploited to measure the shot-to-shot intensity statistics of X-ray pulses.

View Article and Find Full Text PDF

Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues.

View Article and Find Full Text PDF

A method for three-dimensional reconstruction of objects from defocused images collected at multiple illumination directions in high-resolution transmission electron microscopy is presented. The method effectively corrects for the Ewald sphere curvature by taking into account the in-particle propagation of the electron beam. Numerical simulations demonstrate that the proposed method is capable of accurately reconstructing biological molecules or nanoparticles from high-resolution defocused images under conditions achievable in single-particle electron cryo-microscopy or electron tomography with realistic radiation doses, non-trivial aberrations, multiple scattering, and other experimentally relevant factors.

View Article and Find Full Text PDF

Propagation-based phase-contrast x-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the x-ray attenuation  β and refraction  δ, components of the complex refractive index of distinct materials within an unknown sample.

View Article and Find Full Text PDF

We investigate how an intrinsic speckle tracking approach to speckle-based x-ray imaging is used to extract an object's effective dark-field (DF) signal, which is capable of providing object information in three dimensions. The effective DF signal was extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference beam speckles due to both coherent and diffusive scatter from the sample. Here, we assumed that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric and (b) the object has both attenuating and refractive properties.

View Article and Find Full Text PDF

Quantitative differential phase contrast imaging of materials in atomic-resolution scanning transmission electron microscopy using segmented detectors is limited by various factors, including coherent and incoherent aberrations, detector positioning and uniformity, and scan-distortion. By comparing experimental case studies of monolayer and few-layer graphene with image simulations, we explore which parameters require the most precise characterisation for reliable and quantitative interpretation of the reconstructed phases. Coherent and incoherent lens aberrations are found to have the most significant impact.

View Article and Find Full Text PDF

A droplet bouncing on the surface of a vertically vibrating liquid bath can walk horizontally, guided by the waves it generates on each impact. This results in a self-propelled classical particle-wave entity. By using a one-dimensional theoretical pilot-wave model with a generalized wave form, we investigate the dynamics of this particle-wave entity.

View Article and Find Full Text PDF

It has been argued that in atomic-resolution transmission electron microscopy (TEM) of sparse weakly scattering structures, such as small biological molecules, multiple electron scattering usually has only a small effect, while the in-molecule Fresnel diffraction can be significant due to the intrinsically shallow depth of focus. These facts suggest that the three-dimensional reconstruction of such structures from defocus image series collected at multiple rotational orientations of a molecule can be effectively performed for each atom separately, using the incoherent first Born approximation. The corresponding reconstruction method, termed here Differential Holographic Tomography, is developed theoretically and demonstrated computationally on several numerical models of biological molecules.

View Article and Find Full Text PDF
Article Synopsis
  • The development of X-ray free-electron lasers aims to analyze the electronic structure of single biological molecules without significant radiation damage.
  • The ultra-short pulses generated by these lasers can capture fast atomic motions, but some changes to the electronic structure still occur.
  • This study demonstrates that by using just the two most occupied modes from the analysis of the scattered signal, it's possible to recover the original electron density of a single molecule.
View Article and Find Full Text PDF

It is well known that dynamical diffraction varies with changes in sample thickness and local crystal orientation (due to sample bending). In differential phase contrast scanning transmission electron microscopy (DPC-STEM), this can produce contrast comparable to that arising from the long-range electromagnetic fields probed by this technique. Through simulation we explore the scale of these dynamical diffraction artefacts and introduce a metric for the magnitude of their contribution to the contrast.

View Article and Find Full Text PDF

A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed method requires a single image for extraction of the dark-field signal in two-dimensional projection imaging. In the case of three-dimensional tomographic imaging, the method needs only one image to be collected at each projection angle.

View Article and Find Full Text PDF
Article Synopsis
  • Energy-resolved attenuation in spectral x-ray imaging helps identify and separate different materials, but results in increased noise in images.
  • Combining spectral x-ray imaging with propagation-based phase-contrast imaging can potentially reduce this noise by leveraging wave-optical effects, although the overall impact on material decomposition is not fully understood.
  • Theoretical investigations reveal that phase-contrast benefits material decomposition primarily at specific low-energy thresholds where photoelectric absorption is dominant, and also enhances electron density decomposition using the Alvarez-Macovski model, providing insights for future applications without needing data collection.
View Article and Find Full Text PDF

Optical elements rely on refraction, diffraction, or reflection for light manipulation. Fusing diffractive and refractive functions in a single element provides an extra layer of control over the wave propagation, allowing complex beam shaping through self-aligned, monolithic and miniaturized optics. Using gray-scale lithography with high-current focused Xe ion-beams, we realized hybrid refractive-diffractive micro-axicons that feature diffractive gratings engraved on their conical surfaces.

View Article and Find Full Text PDF

We show that the width of an arbitrary function and the width of the distribution of its values cannot be made arbitrarily small simultaneously. In the case of ergodic stochastic processes, an ensuing uncertainty relationship is then demonstrated for the product of correlation length and variance. A closely related uncertainty principle is also established for the average degree of fourth-order coherence and the spatial width of modes of bosonic quantum fields.

View Article and Find Full Text PDF

X-ray phase contrast imaging can provide improved or complementary information to traditional attenuation-based X-ray imaging, making the field a vast and rapidly evolving research subject. X-ray speckle-based imaging (SBI) is one phase-contrast imaging approach that has shown significant potential in providing both high sensitivity and high resolution while using a very simple experimental setup. With the aim of transferring such phase-contrast-based imaging techniques from synchrotron to laboratory X-ray sources, the issue of the deposited radiation dose still remains to be addressed.

View Article and Find Full Text PDF
Article Synopsis
  • This study presents a new approach using a scientific-CMOS (sCMOS) detector for X-ray imaging, effectively addressing issues like dark current and read-out noise.
  • The detector achieves high spatial resolution (6.71 µm) by analyzing photon interactions with visible light that is produced from X-ray-induced fluorescence.
  • Additionally, it offers good energy resolution (61.2% at 17 keV) and combines well with other imaging techniques to enhance signal quality, achieving a signal-to-noise ratio of 15 with very low X-ray exposure.
View Article and Find Full Text PDF